CHAPTER 3 ND-45669 (E)
Pag e 2 44
Revision 2.0
CM73
COMMAND CODE
TITLE:
MEMORY ALLOCATION FOR STATION SPEED DIALING
73
MAT
4. DATA TABLE:
Note 1:If 1000-Slot Memory Block number “4” is chosen, then the 10-Slot Memory Block number range
is “00” to “49” (see the figure below).
Note 2:If one of the 1000-Slot Memory Blocks is used for System Speed Dialing (indicated with CM08-
110, 111, 112, or 176), it cannot also be used for Station Speed Dialing.
Note 3:
An entry of “342106” would allocate six (6) 10-Slot...

Page 282

ND-45669 (E) CHAPTER 3
Pag e 2 45
Revision 2.0
CM73
COMMAND CODE
TITLE:
MEMORY ALLOCATION FOR STATION SPEED DIALING
73
MAT
Note 4:When CM08-252 is assigned as 0, only 3000 Station Speed Dialing numbers can be assigned,
and 1000- Slot Memory Block number 0-2 contains 26-digits memory buffers.
When CM08-252 is assigned as 1, 4500 Station Speed Dialing numbers can be assigned, and
1000-Slot Memory Block number 0-4 contains 16 digits-memory buffers.
Note 5:If the system provides the Extension Memory card,...

Page 283

CHAPTER 3 ND-45669 (E)
Pag e 2 46
Revision 2.0
CM73
COMMAND CODE
TITLE:
MEMORY ALLOCATION FOR STATION SPEED DIALING
73
MAT
• Concept of the Abbreviated Codes
The abbreviated codes for Station Speed Dialing are automatically determined by assigning
this command on a station basis (see figure below).
• If the quantity of Memory Parcels per Station
(or per Station Group) does not exceed 10, then Abbreviated Code = 0 – X.
• If the quantity of Memory Parcels per Station
(or per Station Group) exceeds 11, then...

Page 284

ND-45669 (E) CHAPTER 3
Addendum-002 Page 247
JANUARY, 1999 Revision 2.2
CM74
COMMAND CODE
TITLE:
STORED NUMBER FOR STATION SPEED DIALING
74
MAT
4. DATA TABLE:
1. MEMORY SLOT NUMBER =1000-Slot Memory Block number (0-4, 8-F) + 10-Slot Mem-
ory Block number (00-99) + Memory Parcel number (0-9)
For example, an entry of “3428” represents: 1000-Slot Memory Block number 3
+
10-Slot Memory Block number 42
+
Memory Parcel number 8
2. STORED NUMBER = Access Code + Separator Mark + Number
• Access Code: C.O....

Page 285

CHAPTER 3 ND-45669 (E)
Pag e 2 48
Revision 2.0
CM76
COMMAND CODE
TITLE:
DIGIT CONVERSION ON DID CALL
76
4. DATA TABLE:
1. FUNCTION:
This command is used to assign the data required for interpreting the dialed-in digits.
2. PRECAUTION:
The first digit in the RECEIVED DIGITS field must be assigned, in CM20 Y = 0-3, as a station number
801-811.
3. ASSIGNMENT PROCEDURE:
: Initial Data
Y
RECEIVED DIGITSSETTING DATA
REMARKS
No. MEANING DATA MEANING
0
1For Day mode
For Night modeX-XXXX:
Station number received...

Page 286

ND-45669 (E) CHAPTER 3
Pag e 2 49
Revision 2.0
CM76
COMMAND CODE
TITLE:
DIGIT CONVERSION ON DID CALL
76
4 Day/Night Mode 
Distinction of tenant 
for each station as-
signment by Direct 
Inward DialingX-XXXX:
DID Incoming LDN00
63
None Tenant 00
Tenant 63
Depends on trunk 
tenant or station 
tenant
(CM08-058) set by 
CM76 Y = 0CM08-264
CM35-18
5 Call Waiting for 
DID call per DID in-
coming LDN0 
1 Restricted
Allowed
6 Priority Queuing per 
DID incoming LDN0
1 Not provided
To provide
8 Automatic Live...

Page 287

CHAPTER 3 ND-45669 (E)
Pag e 2 50
Revision 2.0
CM76
COMMAND CODE
TITLE:
DIGIT CONVERSION ON DID CALL
76
nData settings for Day/Night Mode Distinction of tenant.
An explanation of tenant selection method for Day/Night Mode change, when a Direct Inward
Dialing call terminates, is shown below as a tree diagram for system data registration.
(1) Example: data settings for tenant associated with each station assignment number
(CM08-264-0)
CM76-4
Tenant
DAY/NIGHT 
mode
STA
DXXTerminates at station set by...

Page 288

ND-45669 (E) CHAPTER 3
Pag e 2 51
Revision 2.0
CM76
COMMAND CODE
TITLE:
DIGIT CONVERSION ON DID CALL
76
(2) Example: data settings associated with station tenant or trunk tenant (CM08-264-1)
1
STA
DXX
For each termi-
nation method
DAY
NIGHT
CM76-0CM76-1
CM08-058
Terminates at 
station set by 
CM76-1
Terminates at station set by
CM76-0
STA
DXX
Station tenant DAY/NIGHT 
mode change set by CM76-0
0
1
Terminating Trunk tenant 
DAY/NIGHT mode change
For each terminating method
DAY
NIGHT
STA DXX
Terminates at...

Page 289

CHAPTER 3 ND-45669 (E)
Pag e 2 52
Revision 2.0
CM77
COMMAND CODE
TITLE:
Station/Trunk Name Asignment
77
MAT
4. DATA TABLE:
Note 1:The characters available for assigning are 0 – 9, A – Z for MAT/Multiline Terminal.
Note 2:Station Name assignment is also available in each Multiline Terminal or ATTCON by using the
access code assigned with CM20-A10.
Note 3:Trunk names are assigned on a Trunk Route basis only.
1. FUNCTION:
This command is used to assign the name of each station and trunk route which is...

Page 290

ND-45669 (E) CHAPTER 3
Pag e 2 53
Revision 2.0
CM77
COMMAND CODE
TITLE:
Station/Trunk Name Asignment
77
MAT
• Character Code Table
1ST
2ND234567
0
0@P \ p
1!1AQaq
2,,2BRb r
3#3CSc s
4$4DTd t
5%5 EU e u
6&6 FV f v
7,7GWgw
8(8HXhx
9)9IYiy
A*: JZjz
B+;K[k{
C,N^n®
F/?O_
o¬ 