Page 21

NEAX2400 IPX Hotel Feature Programming Manual
NDA-24304, Issue 1Page 7
Numbering Plan
Commands Related to the Numbering Plan
This section explains the commands related to the Numbering Plan and also explains command assignment
procedure. For details of a specific command, refer to the NEAX2400 IPX Office Data Specification Manual.
1. ASYD (Assignment of System Data) - The system data pertaining to the Numbering Plan is as follows:
a.) SYS1 INDEX 160 b
6- This data is for determining whether the Numbering...

Page 22

NEAX2400 IPX Hotel Feature Programming ManualPage 8NDA-24304, Issue 1
Numbering Plan
b.) When the Table is to be provided in common for Administration and Guest stations.
(b
6=1)
c.) When the Table is to be provided separately for Administration and Guest stations.
(b
6=0)
Note:Administration stations can call Guest stations, but calls from Guest stations to Administration stations are
restricted. A call from a Guest Station to a predetermined Administration Station is allowed via Same
Number Access...

Page 23

NEAX2400 IPX Hotel Feature Programming Manual
NDA-24304, Issue 1Page 9
Numbering Plan
Note:When the Timing start service is used, the minimum required number of digits is assigned to the station
number of larger number of digits.
For example, when Station Number 200 and Station Number 2000 exist, Number of Necessary Digits
(NND) = 4 is to be assigned with respect to the 1st Digit (1st DC) = 2.
3. A dummy number (SID36, STATE 63) is necessary for the following case: When the NEAX2400 IPX has
stations...

Page 24

NEAX2400 IPX Hotel Feature Programming ManualPage 10NDA-24304, Issue 1
Numbering Plan
Entry Procedure:
START
ASYD
AANP
SYS1INDEX 160, b6=0
Numbering Plan Development Table is provided separately for
Administration and Guest.
INDEX 161, b
6=0
Use of “#” code in the Timing Start Service is made effective.
INDEX 165, b
7=1
Floor Service is provided.
With respect to the 1st digit code (1ST DC), assign Number of
Necessary Digits (NND) as follows.
1ST DC
NND
01
14
24
34
44
54
91
With respect to the 1st digit...

Page 25

NEAX2400 IPX Hotel Feature Programming Manual
NDA-24304, Issue 1Page 11
Numbering Plan
AGSP
ASPS
With respect to the Access Code (ACC) assign service features
as follows:
ACC
SRVSIDNo.KIND
0 2(SSC) 57 0 0
8 2(SSC) 56 0 -
ACC
SRVRT
9OGC1
With respect to the data assigned by AASP and AGSP, assign
service features as follows:
No.
FSRVSIDSTN
0 0 2(SSC) 2 -
0 1 STN - 4000
Assign the station data of Administration stations. Also, assign
the data for floor service as follows:
STN
ROOM CLASS
“3000” ~ “3500” 0...

Page 26

NEAX2400 IPX Hotel Feature Programming ManualPage 12NDA-24304, Issue 1
This page is for your notes. 

Page 27

NEAX2400 IPX Hotel Feature Programming Manual
NDA-24304, Issue 1Page 13
Description of Service Features
Description of Service Features
Hotel Service Features
This section explains each Hotel service feature by the following items:
General Description
Operating Procedure
Service Conditions
Assignment Procedure
General Description
This item explains a general description of the service feature.
Operating Procedure
This item explains the procedure to be followed for receiving a specific service feature...

Page 28

NEAX2400 IPX Hotel Feature Programming ManualPage 14NDA-24304, Issue 1
This page is for your notes. 

Page 29

NEAX2400 IPX Hotel Feature Programming Manual
NDA-24304, Issue 1Page 15
Automatic Wake-Up A-10
A-10Automatic Wake-Up
General Description
This service feature allows the NEAX2400 IPX to be programmed to automatically call Guest rooms at specified
times. Upon answering, the Guest is connected to a recorded announcement or music source. A printout of
unanswered or blocked wake-up attempts for Guest rooms is provided at the Hotel printer. This feature can be
activated from the Guest room stations,...

Page 30

NEAX2400 IPX Hotel Feature Programming ManualPage 16NDA-24304, Issue 1
A-10 Automatic Wake-Up
Operating Procedure (cont’d)
b.) Dial SET WAKE-UP code. Hear special dial tone.
c.) Dial desired time of AUTOMATIC WAKE-UP, then dial the Guest room number. Hear service
set tone.
d.) Hang up.
To cancel AUTOMATIC WAKE-UP from a Special Administration Station
1. Lift the handset. Receive dial tone.
2. Dial CANCEL WAKE-UP code and Guest room number. Hear service set tone.
3. Hang up.
To set AUTOMATIC WAKE-UP from...