CHAPTER 5 NDA-24299
Page 86
Revision 1.0
DATA PROGRAMMING
Assignment of FCH Related Data
STEP 2: AFRT (FUSION with FCH only)
Assign connection route numbers as shown below by using the AFRT command.
Figure 5-30   AFRT Sample Data Sheet
The AFRT command display should look similar to Figure 5-31.
Figure 5-31   AFRT Command Display
FCHN = 1
CNT = 1     C_RT : 10LN
LN
LN LN
LN LN
NCN1
2
C_RT=10
Node A
Node BFCIC=1
FCHN=1
FCIC=1FCIC=2
FCIC=n
FCIC=2
FCIC=n
TRK 1
TRK 10 TRK 3TRK 31
TRK 32
TRK 40 .
.
..
.
....

Page 102

NDA-24299 CHAPTER 5Page 87
Revision 1.0
DATA PROGRAMMING
Assignment of FCH Related Data
STEP 3: AFPC Assign routing data for Fusion link using the AFPC command. A maximum of 8 connect ion_routes
and FCHN/FPCN can be assigned on a node basis. The list box labeled FCCH on the AFPC command
determines the network configuration type between self-node and the intermediate node. Assign  “0 ”
for  “Fusion System without FCH ” and  “1 ” for  “Fusion System with FCH. ”  In case FCCH=1, enter
FCCH number for...

Page 103

CHAPTER 5 NDA-24299
Page 88
Revision 1.0
DATA PROGRAMMING
Assignment of FCH Related Data
  
Figure 5-34   AFPC Sample Data Sheet
FPC 2(to Node B) FCCH 0(without FCH )
C N T     C _R T       F P C N
1         1 0                2
FPC 21 (to Node C) FCCH 0 (without FCH0)
C N T     C _ R T       F P C N
1          10                 2
Assign all nodes data in the same manner. T his tab le  sh ow s a sam ple d ata  she et for N o de  A  on  the  fu sion  ne tw o rk w ith  F C H . A ssign  the  da ta for a ll...

Page 104

NDA-24299 CHAPTER 5
Page 89
Revision 1.0
DATA PROGRAMMING
Assignment of FCH Related Data
Note:
When one Fusion Network take the configuration with FCH and without FCH together, it is necessary to
assign the routing data using both AFPC and AETH command. An example data assignment is shown in
Figure 5-35.
Figure 5-35   AFPC/AETH Sample Data Assignment
STEP 4: ACAN
Assign the Fusion Connection Index Code (FCIC) and the LENs on an adjacent FPC basis.
Figure 5-36 shows a sample data sheet for Node A.
Note:It...

Page 105

CHAPTER 5 NDA-24299
Page 90
Revision 1.0
DATA PROGRAMMING
Assignment of FCH Related Data
Figure 5-36   ACAN Sample Data Sheet
The ACAN command display should look similar to Figure 5-37.
Figure 5-37   ACAN Command Display (example)
7.1 Assignment of Access Code for Tandem Connection via FCCS - ACIS
Tandem connection via FCCS - ACIS link can be established. With use of LDM, appropriate routing data
for each node can be assigned as shown in Figure 5-38.
F P C  =  2      F C IC  =  1         C _ L E N S  =...

Page 106

NDA-24299 CHAPTER 5
Page 91
Revision 1.0
DATA PROGRAMMING
Assignment of FCH Related Data
Figure 5-38   Assignment of Routing Data Using LDM
Note:
When the related data is assigned to DM, outgoing connection is available only for external routes in self
node (i.e. FCCS - ACIS link cannot be established).
To initiate seizure of an external trunk, use one of four methods - OGC, OGCA, LCR, LCRS. (See the
following sections).
7.1.1 OGC
A procedure for assigning the OGC access code is explained in Figure...

Page 107

CHAPTER 5 NDA-24299
Page 92
Revision 1.0
DATA PROGRAMMING
Assignment of FCH Related Data
STEP 1: ANPDN/ANPDL  Note
Assign the first digit of the OGC access code. When the access code is common to all nodes, use the
ANPDN command. When the access code is assigned for each node, use the ANPDL command.
1st DC=9 CI=N (Normal)NND=1
1st DC=9 CI=H (Hooking)NND=1
STEP 2: ASPAN/ASPAL  
Note
Assign the OGC access code. When the access code is common to all nodes, use the ASPAN
command. When the access code is...

Page 108

NDA-24299 CHAPTER 5
Page 93
Revision 1.0
DATA PROGRAMMING
Assignment of FCH Related Data
Figure 5-40   Example of OGCA
STEP 1: ANPDN/ANPDL  Note
Assign the first digit of the OGCA access code. When the access code is common to all nodes, use
the ANPDN command. When the access code is assigned for each node, use the ANPDL command.
1st DC=9 CI=N (Normal) NND=1
1st DC=9 CI=H (Hooking)NND=1
STEP 2: ASPAN/ASPAL  
Note
Assign the OGCA access code. When the access code is common to all nodes, use the ASPAN...

Page 109

CHAPTER 5 NDA-24299
Page 94
Revision 1.0
DATA PROGRAMMING
Assignment of FCH Related Data
STEP 3: ANNDL/AMND
Assign the necessary number of digits using the ANNDL or the AMND command depending on the
route data.
When the ARTD command OSGS is 2 (Second Dial Tone), use the ANNDL (Necessary Digits
Data) command.
RT=100 OG NND=12
RT=200 OG NND=12
When the ARTD command OSGS is 4/6/7 (Sender Immediate Start/Sender Delay Dial Start/
Sender Wink Start), use the AMND command.
DC=9 MND=12
STEP 4: ARSCN
Assign the...

Page 110

NDA-24299 CHAPTER 5
Page 95
Revision 1.0
DATA PROGRAMMING
Assignment of FCH Related Data
STEP 1: ANPDN/ANPDL  Note
Assign the first digit of the LCR/LCRS access code. When the access code is common to all nodes,
use the ANPDN command. When the access code is assigned for each node, use the ANPDL
command.
TN=1 1st DC=8 CI=N (Normal)NND=1
TN=1 1st DC=8 CI=H (Hooking)NND=1
STEP 2: ASPAN/ASPAL   
Note
Assign the LCR/LCRS access code for a dummy route number. When the access code is common to
all nodes, use...