Page 51

CHAPTER 4 NDA-24299
Page 36
Revision 1.0
INSTALLATION
Key Setting on Circuit Cards
Note 1:
64Kbps is used for T1 or E1 interface.
56Kbps is used for T1 interface with bit stealing.
48Kbps is used for T1 interface with both bit stealing and Zero Code Suppression (or Bit 7 Stuffing).
Note 2:When n is bigger than 1, Time Slot Sequence Integrity (TSSI) must be guaranteed at the network side.
Note 3:The following is an example key setting when n = 2.
SW11-1 = ON
SW11-2 = ON
Table 4-2 MODE Switch Setting...

Page 52

NDA-24299 CHAPTER 4
Page 37
Revision 1.0
INSTALLATION
Key Setting on Circuit Cards
2.3 PA-24DTR (DTI)
There are two types of the PA-24DTR (DTI) card as shown below. Refer to Figure 4-6 and Table 4-4 to set
each switch to the proper positions.
Figure 4-6   Switch Locations on DTI (PA-24DTR) Card
Table 4-4 Switch Setting Patterns for the DTI Card
SWITCH NAMESWITCH 
NUMBERSETTINGSTANDARD 
SETTINGMEANING
MB
UP Circuit card make busy
DOWN×Circuit card make busy cancel
SW13B0ON Internal Loopback: Set...

Page 53

CHAPTER 4 NDA-24299
Page 38
Revision 1.0
INSTALLATION
Key Setting on Circuit Cards
SW4D1ON Transmission Signal A Logic: Negative
OFF×Transmission Signal A Logic: Positive
2ON Receiving Signal A Logic: Negative
OFF×Receiving Signal A Logic: Positive
3ON RMT Alarm Sending: Not to be sent out
OFF×RMT Alarm Sending: To be sent out
4ON×Simultaneous Seizure Supervision: Not to be 
controlled
OFFSimultaneous Seizure Supervision: To be 
controlled
5ON Data Link Control: MOS
OFF×Data Link Control: BOS
6ON...

Page 54

NDA-24299 CHAPTER 4
Page 39
Revision 1.0
INSTALLATION
Key Setting on Circuit Cards
SW391ON
OFF×
2ON×
OFF
3ON×
OFF
4ON×
OFF
5ON×
OFF
6ON
OFF×
7ON×
OFF
8ON
OFF× Table 4-4 Switch Setting Patterns for the DTI Card (Continued)
SWITCH NAMESWITCH 
NUMBERSETTINGSTANDARD 
SETTINGMEANING
1
234
OFF
SW39-1 SW39-2 PAD CONTROL
ON ON Both directions 
OFF ON Receiving only
ON OFF Sending only
OFF OFF ARTD is fixed
SW39-3 SW39-4 DATA PAD
ON ON 64K
OFF ON 56K
ON OFF 48K
OFF OFF 64K INV.
SW39-5 SW39-6 T SIG CONTROL
ON ON...

Page 55

CHAPTER 4 NDA-24299
Page 40
Revision 1.0
INSTALLATION
Key Setting on Circuit Cards
SW6C1ON×Fixed
2ON×Fixed
3ON×Fixed
4ON×Fixed
5ON×Fixed
6ON×Fixed
7ON×Fixed
8ON×Fixed
SW581ON Equalizer Setting
OFF
2ON
OFF
3ON
OFF
4ONPAD Pattern Selection
Note:When setting this key, refer to Digital
PAD Setting Table (Table 4-5). OFF×
5ON×
OFF
6ON×
OFF
7ON
Alarm Sending when this circuit card is in N-
OPE state. OFF×
8ON×
OFF Table 4-4 Switch Setting Patterns for the DTI Card (Continued)
SWITCH NAMESWITCH...

Page 56

NDA-24299 CHAPTER 4
Page 41
Revision 1.0
INSTALLATION
Key Setting on Circuit Cards
Note:
This switch setting is applicable for a system that adopts Associated Channel Interoffice Signalling (ACIS).
2.4 Digital PAD Setting
The PA-24DTR card is equipped with a mask ROM in which the following typical PAD patterns have been
already written. PAD value is determined with the selection of a desired PAD pattern, which can be done
by key setting of the SW 58 (elements 4, 5, 6) on the card, and programming of the...

Page 57

CHAPTER 4 NDA-24299
Page 42
Revision 1.0
INSTALLATION
Mounting Circuit Cards in PIM
3. Mounting Circuit Cards in PIM
3.1 Mounting HUB (PA-M96) in a PIM
Mount the HUB (PA-M96) card in an appropriate slot of a PIM as shown in Figure 4-7. When the MAT is
connected via a HUB card, be sure to use a dedicated HUB for the Fusion link.
Note:HUB (PA-M96) can be mounted anywhere in a PIM of any IMG stack. However, if your system is 1-IMG
type, mount the HUB in PIM0.
Figure 4-7   Mounting HUB Card in  PIM 0...

Page 58

NDA-24299 CHAPTER 4
Page 43
Revision 1.0
INSTALLATION
Mounting Circuit Cards in PIM
3.2 Mounting FCH (PA-FCHA) and DTI (PA-24DTR) Cards
Mount the FCH (PA-FCHA) and the DTI (PA-24DTR) card in appropriate slots in a PIM. Mount the two
cards in adjacent slots since these cards must be connected on the front connectors. Figure 4-8 shows an
example with the FCH and DTI cards mounted in PIM 1.
Figure 4-8   Mounting FCH and DTI Cards
ATTENTIONContents
Static Sensitive
Handling
Precautions Required
HUB
HUB
DTI...

Page 59

CHAPTER 4 NDA-24299
Page 44
Revision 1.0
INSTALLATION
Connecting Cables
4. Connecting Cables
4.1 Connecting DTI-FCH Front Cables
Connect the furnished front cable to the connectors on the DTI and FCH cards. Use DTI and CN2
connectors on the FCH and DTI cards respectively. Since an FCH card is equipped with one Handler
circuit, a maximum of five FCH cards can be connected to a DTI card. (See Figure 4-9.) However, if a DCH
card is also cascaded, a maximum of three FCH cards can be added to the DTI card....

Page 60

NDA-24299 CHAPTER 4
Page 45
Revision 1.0
INSTALLATION
Connecting Cables
Since a maximum of five Handler circuits can be used, five FCH cards can be cascaded. Figure 4-10 shows an 
example where three FCH cards are cascaded.
Figure 4-10   FCH Cascade Connections
ATTENTIONContents
Static Sensitive
Handling
Precautions Required
 
222
DTI
CN2
FCH
FRONT VIEW
OVERVIEW
       DTI  
(PA-24DTR) FCH(PA-FCHA)
10AL(10)FLT CA
FCH x 3
DTI
10AL(10)FLT CA 