NEC Neax 2400 Ipx Fusion Network System Manual
Here you can view all the pages of manual NEC Neax 2400 Ipx Fusion Network System Manual. The NEC manuals for Communications System are available online for free. You can easily download all the documents as PDF.
Page 51
CHAPTER 4 NDA-24299 Page 36 Revision 1.0 INSTALLATION Key Setting on Circuit Cards Note 1: 64Kbps is used for T1 or E1 interface. 56Kbps is used for T1 interface with bit stealing. 48Kbps is used for T1 interface with both bit stealing and Zero Code Suppression (or Bit 7 Stuffing). Note 2:When n is bigger than 1, Time Slot Sequence Integrity (TSSI) must be guaranteed at the network side. Note 3:The following is an example key setting when n = 2. SW11-1 = ON SW11-2 = ON Table 4-2 MODE Switch Setting...
Page 52
NDA-24299 CHAPTER 4 Page 37 Revision 1.0 INSTALLATION Key Setting on Circuit Cards 2.3 PA-24DTR (DTI) There are two types of the PA-24DTR (DTI) card as shown below. Refer to Figure 4-6 and Table 4-4 to set each switch to the proper positions. Figure 4-6 Switch Locations on DTI (PA-24DTR) Card Table 4-4 Switch Setting Patterns for the DTI Card SWITCH NAMESWITCH NUMBERSETTINGSTANDARD SETTINGMEANING MB UP Circuit card make busy DOWN×Circuit card make busy cancel SW13B0ON Internal Loopback: Set...
Page 53
CHAPTER 4 NDA-24299 Page 38 Revision 1.0 INSTALLATION Key Setting on Circuit Cards SW4D1ON Transmission Signal A Logic: Negative OFF×Transmission Signal A Logic: Positive 2ON Receiving Signal A Logic: Negative OFF×Receiving Signal A Logic: Positive 3ON RMT Alarm Sending: Not to be sent out OFF×RMT Alarm Sending: To be sent out 4ON×Simultaneous Seizure Supervision: Not to be controlled OFFSimultaneous Seizure Supervision: To be controlled 5ON Data Link Control: MOS OFF×Data Link Control: BOS 6ON...
Page 54
NDA-24299 CHAPTER 4 Page 39 Revision 1.0 INSTALLATION Key Setting on Circuit Cards SW391ON OFF× 2ON× OFF 3ON× OFF 4ON× OFF 5ON× OFF 6ON OFF× 7ON× OFF 8ON OFF× Table 4-4 Switch Setting Patterns for the DTI Card (Continued) SWITCH NAMESWITCH NUMBERSETTINGSTANDARD SETTINGMEANING 1 234 OFF SW39-1 SW39-2 PAD CONTROL ON ON Both directions OFF ON Receiving only ON OFF Sending only OFF OFF ARTD is fixed SW39-3 SW39-4 DATA PAD ON ON 64K OFF ON 56K ON OFF 48K OFF OFF 64K INV. SW39-5 SW39-6 T SIG CONTROL ON ON...
Page 55
CHAPTER 4 NDA-24299 Page 40 Revision 1.0 INSTALLATION Key Setting on Circuit Cards SW6C1ON×Fixed 2ON×Fixed 3ON×Fixed 4ON×Fixed 5ON×Fixed 6ON×Fixed 7ON×Fixed 8ON×Fixed SW581ON Equalizer Setting OFF 2ON OFF 3ON OFF 4ONPAD Pattern Selection Note:When setting this key, refer to Digital PAD Setting Table (Table 4-5). OFF× 5ON× OFF 6ON× OFF 7ON Alarm Sending when this circuit card is in N- OPE state. OFF× 8ON× OFF Table 4-4 Switch Setting Patterns for the DTI Card (Continued) SWITCH NAMESWITCH...
Page 56
NDA-24299 CHAPTER 4 Page 41 Revision 1.0 INSTALLATION Key Setting on Circuit Cards Note: This switch setting is applicable for a system that adopts Associated Channel Interoffice Signalling (ACIS). 2.4 Digital PAD Setting The PA-24DTR card is equipped with a mask ROM in which the following typical PAD patterns have been already written. PAD value is determined with the selection of a desired PAD pattern, which can be done by key setting of the SW 58 (elements 4, 5, 6) on the card, and programming of the...
Page 57
CHAPTER 4 NDA-24299 Page 42 Revision 1.0 INSTALLATION Mounting Circuit Cards in PIM 3. Mounting Circuit Cards in PIM 3.1 Mounting HUB (PA-M96) in a PIM Mount the HUB (PA-M96) card in an appropriate slot of a PIM as shown in Figure 4-7. When the MAT is connected via a HUB card, be sure to use a dedicated HUB for the Fusion link. Note:HUB (PA-M96) can be mounted anywhere in a PIM of any IMG stack. However, if your system is 1-IMG type, mount the HUB in PIM0. Figure 4-7 Mounting HUB Card in PIM 0...
Page 58
NDA-24299 CHAPTER 4 Page 43 Revision 1.0 INSTALLATION Mounting Circuit Cards in PIM 3.2 Mounting FCH (PA-FCHA) and DTI (PA-24DTR) Cards Mount the FCH (PA-FCHA) and the DTI (PA-24DTR) card in appropriate slots in a PIM. Mount the two cards in adjacent slots since these cards must be connected on the front connectors. Figure 4-8 shows an example with the FCH and DTI cards mounted in PIM 1. Figure 4-8 Mounting FCH and DTI Cards ATTENTIONContents Static Sensitive Handling Precautions Required HUB HUB DTI...
Page 59
CHAPTER 4 NDA-24299 Page 44 Revision 1.0 INSTALLATION Connecting Cables 4. Connecting Cables 4.1 Connecting DTI-FCH Front Cables Connect the furnished front cable to the connectors on the DTI and FCH cards. Use DTI and CN2 connectors on the FCH and DTI cards respectively. Since an FCH card is equipped with one Handler circuit, a maximum of five FCH cards can be connected to a DTI card. (See Figure 4-9.) However, if a DCH card is also cascaded, a maximum of three FCH cards can be added to the DTI card....
Page 60
NDA-24299 CHAPTER 4 Page 45 Revision 1.0 INSTALLATION Connecting Cables Since a maximum of five Handler circuits can be used, five FCH cards can be cascaded. Figure 4-10 shows an example where three FCH cards are cascaded. Figure 4-10 FCH Cascade Connections ATTENTIONContents Static Sensitive Handling Precautions Required 222 DTI CN2 FCH FRONT VIEW OVERVIEW DTI (PA-24DTR) FCH(PA-FCHA) 10AL(10)FLT CA FCH x 3 DTI 10AL(10)FLT CA