3.1 Fusion Network Conditions
This section explains conditions when designing a Fusion network. In the following diagram, a Fusion Link
is printed in a thick line while a CCIS link is printed in a dotted line.
Condition 1: The maximum number of nodes on a Fusion network is sixteen (16) nodes.
Figure 3-9   Fusion Network Topologies
23
1
4
Node A     Node B     Node D     Node C 
Node A     Node D...

Page 32

NDA-24299 CHAPTER 3
Page 17
Revision 1.0
SYSTEM CONFIGURATION
System Considerations
Condition 2: A maximum of four (4) Non ACD nodes can be connected as tandem nodes with 1D
channel.
 64k (1D-channel) will support 4 nodes
 128k (2D-channels) will support 5 nodes
 256k (4D-channels) will support 6 nodes
See Figure 3-10.
Figure 3-10   Fusion Tandem Connections
Condition 3: The available connection-route number ranges from 1 to 1023.
Condition 4: The available connection-trunk number of each route ranges...

Page 33

CHAPTER 3 NDA-24299
Page 18
Revision 1.0
SYSTEM CONFIGURATION
System Considerations
Condition 5: Up to eight (8) routes can be assigned as alternate routes for a connection trunk.
See Figure 3-12.
Figure 3-12   Connection Trunk Alternate Routing
Condition 6: Connection trunks and the Fusion data link must be assigned on an “associated” basis.
See Figure 3-13.
Figure 3-13   Fusion Network on an Associated Basis
Condition 7: One Fusion data link must be assigned on each T1 link.
Condition 8: A maximum of...

Page 34

NDA-24299 CHAPTER 3
Page 19
Revision 1.0
SYSTEM CONFIGURATION
System Considerations
Condition 9: The maximum data link speed is “1.5 Mbps.”
Condition 10: Connection Trunks (B ch) conform to the following specifications:
 Existing external trunk cannot be used as alternate routes for connection trunks.
 Billing information on connection trunks cannot be output.
 Under the following conditions, “connection trunk seizure NG” will occur:
Data Link Failure
Connection Trunk all busy
LANI (built-in) - FCH...

Page 35

CHAPTER 3 NDA-24299
Page 20
Revision 1.0
SYSTEM CONFIGURATION
System Considerations
3.2 Centralized Billing - Fusion (Polling Method)
This section explains the conditions of Centralized Billing - Fusion, focusing on when CCIS links are
involved. To use this feature, select Center Node(s) on the Fusion network. See Figure 3-14.
 
Figure 3-14   Centralized Billing - Fusion (1/3)
FCCS
FCCS
FCCS Fusion Network - Node A (Fusion - Center Node) collects the billing inform ation of Nodes B and C via FCCS using...

Page 36

NDA-24299 CHAPTER 3
Page 21
Revision 1.0
SYSTEM CONFIGURATION
System Considerations
Figure 3-14   Centralized Billing - Fusion (2/3)
FCCS
FCC S
Fusion N etw ork - Exam ple 4
- Example 5
CCIS
IP X
IP XIP X
Node B
N ode C
Fusion - Center Node
CCIS - Center Node
FCCS
Fusion Netw ork
Fusion Network
CCISCCIS
CCIS
IP X
non IPX
non IPXIP X
IP X IP X
IP X
Fusion - Center Node
FCCS
FCCS
FCCS
Fusion - Center N ode
DPC0:  
Node D
DPC0:  
Node C
DPC0:  
Node A
CCIS - Center Node
¥ N o d e  A  c o lle cts  th e  b...

Page 37

CHAPTER 3 NDA-24299
Page 22
Revision 1.0
SYSTEM CONFIGURATION
System Considerations
Figure 3-14   Centralized Billing - Fusion (3/3)
FCCS
FCCS
FCCS
F u sion  N etw o rk - Exam ple 7
- Example 8
CCIS
DPC0:  
Node D
C CIS  - C enter N ode
SM DR  equipm ent
SM D R equipm ent Fusion - Center Node
FCCS
FCCS
FCCS
Fusion Network
CCIS
DPC0:  
N ode B
CCIS - Center Node
SM D R equipm ent
SM DR  equipm ent Fusion - C enter N ode
¥ N o d e  A  co lle cts b illin g  in fo rm a tio n  o f N o d e  B  a n d  N o d e...

Page 38

NDA-24299 CHAPTER 3
Page 23
Revision 1.0
SYSTEM CONFIGURATION
System Considerations
3.3 Centralized Management Report-Fusion
For collection of fault information in a Fusion network, the Centralized Management Report-Fusion is
used. This feature provides automatic reporting of fault occurrence from Local Nodes to Center Node.
Figure 3-15 shows service conditions for this feature.
Figure 3-15   Centralized Management Report-Fusion
 Center Node for Centralized Management Report-Fusion is specified in the...

Page 39

CHAPTER 3 NDA-24299
Page 24
Revision 1.0
SYSTEM CONFIGURATION
System Considerations
The following explains service conditions for the network including both FCCS and CCIS links.
Example: 1When the network comprises FCCS and CCIS links (See Figure 3-16.)
Figure 3-16   Centralized Management Report-Fusion (Example 1)
Node A: To send system messages to Node C via Office B, assign Point Code of Node C (12) to ASYD, SYS
1, Indexes 184 and 185.
Node  B: To send system messages to Node C, assign Fusion Point...

Page 40

NDA-24299 CHAPTER 3
Page 25
Revision 1.0
SYSTEM CONFIGURATION
System Considerations
Example: 2
When both FCCS and CCIS links are established between two nodes (See Figure 3-17).
Figure 3-17   Centralized Management Report-Fusion (Example 2)
Node A/B/C:Refer to Example 1 on the previous page.
Node D: When Point Code of Node C (12) is assigned to ASYD, SYS 1, Indexes 184 and 185, System
messages are sent to Node C with use of CCIS. When this system data is not assigned (0), and
Fusion Point Code of Node C...