    							CHAPTER 4 ND-70185 (E)
    Page 46
    Revision 3.0
    INSTALLATION
    Connecting Cables
    4.3.3 When not using the cable unit SR1201 ETIF CAU-n
    When your system doesn’t use the cable unit classified as SR1201 ETIF CAU-n, perform the 10 BASE-
    T connections as instructed below:
    1. Depending on your system configuration, connect the 10 BASE-T straight cable(s) between the
    HUB (PA-M96) and LANI (PZ-PC19) cards. Use the cable UTP CTG5 ST CA-O, which must be
    provided by the user.
    When a single LANI is used for each CPR (Slot 00 only) and the HUB is in a dual configuration,
    connect HUB#0 to LANI#0 and HUB#1 to LANI#1, using two 10 BASE-T cables.
    When dual LANIs are used in both Slot 00 and 03 of CPR#0/CPR#1, use at least two HUB cards
    as separate 10 BASE-T connection terminals: One HUB for the internal LANI (LANI-A in Slot 00
    0f each CPR) and the other for the external LANI (LANI-B: in Slot 03 of each CPR) The external
    LANI is available for Series 7300 Release 3 software or later.
    2. When HUB is in a dual configuration, connect the 10 BASE-T cross cable between the HUB cards.
    Use the cable UTP CTG5 CRS CA-F, which must be provided by the user.
    When using more than two HUB cards, connect the cross cable(s) for the remaining HUB cards,
    except the HUB card used for the MAT connection.
    3. Connect the 10 BASE-T straight cable(s) between the HUB and FCH (PA-FCHA) cards. Use the
    following cables, which must be provided by the user.
    UTP CTG5 ST CA-F: When the HUB and FCH are in the same PIM (PIM0)
    UTP CTG5 ST CA-O: When the HUB and FCH are in different PIMs
    When FCH is in a dual configuration, connect FCH#0 to the HUB#0 side, and FCH#1 to the HUB#1
    side.
    4.3.4 Procedure for 4-IMG System
    When your system is 4-IMG type, the procedure for 10 BASE-T connection is as follows. Because the
    HUB (PA-M96) can be mounted anywhere in a PIM of any IMG, the Ethernet cables must be arranged
    by the user, depending on the system configuration.
    1. Depending on your system configuration, connect the 10 BASE-T straight cable(s) between the
    HUB (PA-M96) and LANI (PZ-PC19) cards. Use the following cable, prepared by the user.
    UTP CTG5 ST CA-O: When the HUB and LANI are in the same IMG (IMG0)
    UTP CTG5 ST CA-X: When the HUB and LANI are in different IMGs
    When a single LANI is used for each CPR (Slot 00 only) and the HUB is in a dual configuration,
    connect HUB#0 and HUB#1 to LANI#1 using two 10 BASE-T cables. 
    						
    							ND-70185 (E) CHAPTER 4
    Page 47
    Revision 3.0
    INSTALLATION
    Connecting Cables
    When dual LANIs are used in both Slot 00 and 03 of CPR#0/CPR#1, be sure to use at least two
    HUB cards as separate 10 BASE-T connection terminals. Use one HUB for the internal LANI
    (LANI-A: in Slot 00 of each CPR) and use the other for the external LANI (LANI-B in Slot 03 of
    each CPR).
    2. When the HUB is in a dual configuration, connect the 10 BASE-T cross cable between the HUB
    cards. Use the following cables, which are provided by the user.
    UTP CTG5 CRS CA-F:When the HUB and HUB are in the same PIM
    UTP CTG5 CRS CA-O:When the HUB and HUB are in different PIMs but in the same IMG
    UTP CTG5 CRS CA-X:When the HUB and HUB are in different IMG stacks
    When using more than two HUB cards, also connect the cross cable(s) for the remaining HUB
    card(s), except the HUB for the MAT connection.
    This step is not necessary when your system uses dual LANIs for CPU#0/CPU#1 and FCH is also
    in a dual configuration.
    3. Connect the 10 BASE-T straight cable(s) between the HUB and FCH (PA-FCHA) cards. Use the
    following cable, which must be provided by the user.
    UTP CTG5 ST CA-F: When the HUB and FCH are in the same PIM
    UTP CTG5 ST CA-O: When the HUB and FCH are in different PIMs but in the same IMG
    UTP CTG5 ST CA-X:When the HUB and FCH are in different IMG stacks
    When FCH is in a dual configuration, connect FCH#0 to the HUB#0 side, and FCH#1 to the HUB#1
    side.
    4.3.5 Procedure for IMX-U System
    When your system is the IMX-U type (configured to a maximum of 4 Local Nodes + 1ISW), the pro-
    cedure for the 10 BASE-T connection is as follows. Because this system already has a Fusion Link via
    the HUB (PA-M96) cards, this section gives details related only to the connection between the HUB and
    FCH (PA-FCHA) cards.
    1. Refer to the NEAX2400 IMX Installation Manual (IMX-U Type) to make sure that the necessary
    10 BASE-T (both straight and cross) connections between the ISW and each LN (Local Node) are
    all securely provided.
    2. Connect the 10 BASE-T straight cable(s) between the HUB (PA-M96) and FCH (PA-FCHA) cards.
    Use the following cable, which must be provided by the user.
    UTP CTG5 ST CA-F: When the HUB and FCH are in the same PIM
    UTP CTG5 ST CA-O:When the HUB and FCH are in different PIMs but in the same IMG
    UTP CTG5 ST CA-X:When the HUB and FCH are in different IMG stacks but in the same LN
    UTP CTG5 ST CA-A0:When the HUB and FCH are in different LNs 
    						
    							CHAPTER 4 ND-70185 (E)
    Page 48
    Revision 3.0
    INSTALLATION
    Connecting Cables
    When dual FCH is provided for the HUB dedicated to each internal LANI card (LANI-A: in Slot
    00 of each CPR), connect FCH#0 to HUB#0 and FCH#1 to HUB#1.
    When your system also uses the external LANI cards (LANI-B in Slot 03 of each CPR), prepare
    another set of FCH cards for the HUB dedicated to the external LANI cards. Then, if the FCH is in
    dual configuration, connect one FCH to the HUB for No. 0 system of the external LANI, and the
    other to the HUB for the No. 1 system of the external LANI.
    Figure 4-12 shows an example of a HUB in a dual configuration and the FCH card mounted in PIM
    1 of the 1 IMG system.
    Figure 4-12   Connecting 10 BASE-T Cables (example)
    ATTENTIONContents
    Static Sensitive
    Handling
    Precautions Required
    DTI
    
    2
    3
    3
    Connect HUB and FCH using a
    10 BASE-T straight cable. 
    Refer to figures listed on the 
    following pages.
    DTI
    FCH
    This figure shows an example where HUB is provided in a dual configuration and FCH card is mounted in PIM1 of 1-IMG system.
    LANI
    LANI
    PIM 1
    PIM 0      
    HUB
    (PA-M96
    )
          HUB
    
    (PA-M96)
    GT
    GT
    2
    Connect two HUB cards using
    a 10 BASE-T cross cable. 
    (When HUB is in dual 
    configuration.) Note
    -
    1
    1
    Connect the LANI and the 
    HUB  card using a 10 BASE-T
    straight cable. Eight 
    10 BASE-T connectors
    (TP0-X  -  TP7-X) are
    furnished on the front edge
    of the HUB card. Use one of 
    the connectors.
    1
    Note
    Note
    Note:This step can be skipped when dual LANIs (LANI-A and LANI-B) are used for each CPU and FCH is
    provided in a dual configuration. 
    						
    							ND-70185 (E) CHAPTER 4
    Page 49
    Revision 3.0
    INSTALLATION
    Connecting Cables
    Figure 4-13 shows some typical examples, where 10 BASE-T cables are connected to the FCH card(s) mounted
    in PIM0 of 1-IMG system, under the following conditions:
    Note 1:Cables Contained in each cable unit are as follows.
    SR1201 ETIF CAU-A: UTP CTG5 ST CA-D, UTP CTG5 ST CA-J
    SR1201 ETIF CAU-DA: UTP CTG5 ST CA-D, UTP CTG5 ST CA-J, UTP CTG5 CRS CA-F
    Note 2:The cables cited in Figure 4-13 can be used in the 1-IMG system only. Refer to Page 45 through Pa g e  4 8
    for more details.
    Figure 4-13   Examples of Ethernet Cable Connection-FCH in PIM0 (1-IMG System) (1/2)Configuration
    of CPUConfiguration
    of LANUsed Cable Unit
    (Note 1, Note 2)Number of  HUB/
    FCH
    Pattern 1 Single Single SR1201 ETIF CAU-A × 1 HUB× 1, FCH× 1
    Pattern 2 Dual SingleSR1201 ETIF CAU-A × 1
    SR1201 ETIF CAU-DA × 1HUB× 2, FCH× 2
    Pattern 3 Single Dual SR1201 ETIF CAU-A × 2 HUB× 2, FCH× 2
    Pattern 4 Dual DualSR1201 ETIF CAU-A × 2
    SR1201 ETIF CAU-DA × 2HUB× 2, FCH× 2
    ATTENTIONContents
    Static Sensitive
    Handling
    Precautions Required
    BSCM
    06 04 05 03 02 01 0006 04 05 03 02 01 00
    CNCN
    HUB
    BASEU
    PIM 1
    PIM 2
    PIM 3
    UTP CTG5 ST CA-J
    PIM 0
    LPM FANU
    FCH
    CNCN
    UTP CTG5 ST CA-D
    TOPU
    FCH (PA-FCHA)HUB (PA-M96)
    TP0-X TP1-X
    TP2-X TP3-X TP4-X TP5-X TP6-X TP7-X
    10 BASE-T
    Connectors for 10 BASE-T
    FRONT VIEWFRONT VIEW
    CN= 10  BASE-T Connector
    Use 10 BASE-T connectors. 
    BSCM06 04 05 03 02 01 00
    06 04 05 03 02 01 00
    CN
    CN
    CN
    CN
    UTP CTG5 ST CA-J
    CNFCH
    HUB
    CN
    CNHUB
    BASEU
    PIM 1
    PIM 2
    PIM 3
    LPM
    CN
       
    PIM 0
    UTP CTG5 CRS CA-F
    CN
    FCHCN
    UTP CTG5 ST CA-D
    TOPU
    FANU 
    						
    							CHAPTER 4 ND-70185 (E)
    Page 50
    Revision 3.0
    INSTALLATION
    Connecting Cables
    Figure 4-13   Examples of Ethernet Cable Connection-FCH in PIM0 (1-IMG System) (2/2)
    ATTENTIONContents
    Static Sensitive
    Handling
    Precautions Required
    06 04 05 03 02 01 0006 04 05 03 02 01 00
    CN
    CNCN
    CN
    HUB
    CN
    CNHUB
    BASEU
    PIM 1
    PIM 2
    PIM 3
    UTP CTG5 ST CA-J
    PIM 0
    LPMTOPU
    FANU
    BSCM
    CN
    FCH
    CN
    UTP CTG5 ST CA-J
    FCH
    CNCN
    UTP CTG5 ST CA-D
       
    06 04 05 03 02 01 00
    06 04 05 03 02 01 00
    CN
    CN
    CN
    CN
    CNCN
    CNUTP CTG5 ST CA-J
    CN
    FCH
    HUB
    CN
    CNHUB
    BASEU
    PIM 1
    PIM 2
    PIM 3
    LPM
    CN
    CN
    TOPU
    FANU
    PIM 0CNFCHCN
    UTP CTG5 ST CA-D
    UTP CTG5 ST CA-J
    BSCM
    Note:  When dual LANIs are used in both slot 00 and 03 of CPR (Pattern 3 or 4), be sure to use at least two HUB cards: 
                One HUB for internal LANI (in slot 00) and the other for external LANI (in slot 03: available for Release 3 or 
                later software). However, if this is the case and FCH is also in a dual configuration, the 10 BASE-T “cross” 
                connection between the HUBs is not required.  
    						
    							ND-70185 (E) CHAPTER 4
    Page 51
    Revision 3.0
    INSTALLATION
    Connecting Cables
    Figure 4-14 shows some typical examples, where 10 BASE-T cables are connected to the FCH card(s) mounted
    in PIM1 of 1-IMG system, under the following conditions:
    Note 1:Cables contained in each cable unit are as follows.
    SR1201 ETIF CAU-B: UTP CTG5 ST CA-K, UTP CTG5 ST CA-J
    SR1201 ETIF CAU-DB: UTP CTG5 ST CA-I, UTP CTG5 ST CA-J, UTP CTG5 CRS CA-F
    Note 2:The cables cited in Figure 4-14 can be used in the 1-IMG system only. Refer to Page 45 through Pa g e  4 8
    for more details.
    Figure 4-14   Examples of Ethernet Cable Connection-FCH in PIM1 (1-IMG System)Configuration
    of CPUConfiguration
    of LANUsed Cable Unit
    (Note 1, Note 2)Number of  HUB/
    FCH
    Pattern 1 Single Single SR1201 ETIF CAU-B × 1 HUB× 1, FCH× 1
    Pattern 2 Dual SingleSR1201 ETIF CAU-B × 1
    SR1201 ETIF CAU-DB × 1HUB× 2, FCH× 2
    Pattern 3 Single Dual SR1201 ETIF CAU-B × 2 HUB× 2, FCH× 2
    Pattern 4 Dual DualSR1201 ETIF CAU-B × 2
    SR1201 ETIF CAU-DB × 2HUB× 2, FCH× 2
    ATTENTIONContents
    Static Sensitive
    Handling
    Precautions Required
    06 04 05 03 02 01 0006 04 05 03 02 01 00
    CNCN
    HUB
    BASEU
    PIM 1
    PIM 2
    PIM 3
    UTP CTG5 ST CA-J
    PIM 0
    LPM TOPU
    FANU
    BSCM
    FCH
    CN
    CN
    UTP CTG5 ST CA-K
    BSCM06 04 05 03 02 01 00
    06 04 05 03 02 01 00
    CN
    CN
    CN
    CN
    UTP CTG5 ST CA-J
    CNFCH
    HUB
    CN
    CN
    HUB
    BASEU
    PIM 1
    PIM 2
    PIM 3
    LPM
    CN
    TOPU
    FANU
    PIM 0
    UTP CTG5 CRS CA-F
    CNFCH
    CNUTP CTG5 ST CA-K
    UTP CTG5 ST CA-I
       
    FCH (PA-FCHA)HUB (PA-M96)
    TP0-X TP1-X
    TP2-X TP3-X TP4-X TP5-X TP6-X TP7-X
    10 BASE-T
    Connectors for 10 BASE-T
    FRONT VIEWFRONT VIEW
    CN= 10  BASE-T Connector
    Use 10 BASE-T connectors.  
    						
    							CHAPTER 4 ND-70185 (E)
    Page 52
    Revision 3.0
    INSTALLATION
    Connecting Cables
    Figure 4-15 shows some typical examples, where 10 BASE-T cables are connected to the FCH card(s) mounted
    in PIM2 of 1-IMG system, under the following conditions:
    Note 1:Cables contained in each cable unit are as follows.
    SR1201 ETIF CAU-C: UTP CTG5 ST CA-M, UTP CTG5 ST CA-J
    SR1201 ETIF CAU-DC: UTP CTG5 ST CA-K, UTP CTG5 ST CA-J, UTP CTG5 CRS CA-F
    Note 2:The cables cited in Figure 4-15 can be used in the 1-IMG system only. Refer to Page 45 through Pa g e  4 8
    for more details.
    Figure 4-15   Examples of Ethernet Cable Connection-FCH in PIM2 (1-IMG System) (1/2)Configuration
    of CPUConfiguration
    of LANUsed Cable Unit
    (Note 1, Note 2)Number of  HUB/
    FCH
    Pattern 1 Single Single SR1201 ETIF CAU-C × 1 HUB× 1, FCH× 1
    Pattern 2 Dual SingleSR1201 ETIF CAU-C × 1
    SR1201 ETIF CAU-DC × 1HUB× 2, FCH× 2
    Pattern 3 Single Dual SR1201 ETIF CAU-C × 2 HUB× 2, FCH× 2
    Pattern 4 Dual DualSR1201 ETIF CAU-C × 2
    SR1201 ETIF CAU-DC × 2HUB× 2, FCH× 2
    ATTENTIONContents
    Static Sensitive
    Handling
    Precautions Required
    06 04 05 03 02 01 0006 04 05 03 02 01 00
    CNCN
    HUB
    BASEU
    UTP CTG5 ST CA-J
    FANU
    BSCM
    FCH
    CN
    CN
    UTP CTG5 ST CA-M
    TOPU
    PIM 1
    PIM 2
    PIM 3
    PIM 0
    LPM
    06 04 05 03 02 01 00
    06 04 05 03 02 01 00
    CN
    CN
    CN
    CN
    UTP CTG5 ST CA-J
    CNFCH
    HUB
    CN
    CNHUB
    BASEU
    PIM 1
    PIM 2
    PIM 3
    LPM
    CN
    FANU
    PIM 0UTP CTG5 CRS CA-F
    CNFCH
    CN
    UTP CTG5 ST CA-M
    UTP CTG5 ST CA-K
    BSCM
    TOPU
       
    FCH (PA-FCHA)HUB (PA-M96)
    TP0-X TP1-X
    TP2-X TP3-X TP4-X TP5-X TP6-X TP7-X
    10 BASE-T
    Connectors for 10 BASE-T
    FRONT VIEWFRONT VIEW
    CN= 10  BASE-T Connector
    Use 10 BASE-T connectors.  
    						
    							ND-70185 (E) CHAPTER 4
    Page 53
    Revision 3.0
    INSTALLATION
    Connecting Cables
    Figure 4-15   Examples of Ethernet Cable Connection-FCH in PIM2 (1-IMG System) (2/2)
    ATTENTIO NContents
    Static Sensitive
    Handling
    Precautions Required
    06 04 05 03 02 01 00
    06 04 05 03 02 01 00
    CN
    CN
    CN
    CNCN
    CNUTP CTG5 ST CA-J
    CNFC H
    HUB
    CN
    HUB
    BASEU
    PIM 1
    PIM 2
    PIM  3
    LPM
    CN
    CN
    FANU
    PIM 0
    CN
    FCH
    CN
    UTP CTG5 ST CA-M
    UTP CTG5 ST CA-K
    UTP CTG5 ST CA-J
    TO PU
    06 04 05 03 02 01 0006 04 05 03 02 01 00
    CN
    CNCN
    CN
    HUB
    CN
    CNHUB
    BASEU
    PIM  1
    PIM 2
    PIM  3
    UTP CTG5 ST CA-J
    PIM 0
    LPMFANU
    BSCM BSCM
    CN
    FC H
    CN
    FCH
    CN
    CN
    UTP CTG5 ST CA-MUTP CTG5 ST CA-J
    TO PU
    < F C H  in P IM 2 (P attern 3)>   
    Note:When dual LANIs are used in both Slot 00 and 03 of CPR (Pattern 3 or 4), be sure to use at least 
    two HUB cards: One HUB for internal LANI (in Slot 00) and the other for external LANI (in Slot 
    03). However, if this is the case and FCH is also in a dual configuration, the 10 BASE-T “cross” 
    connection between the HUBs is not required.  
    						
    							CHAPTER 4 ND-70185 (E)
    Page 54
    Revision 3.0
    INSTALLATION
    Connecting Cables
    Figure 4-16 shows some typical examples, where 10 BASE-T cables are connected to the FCH card(s) mounted
    in PIM3 of 1-IMG system, under the following conditions:
    Note 1:Cables contained in each cable unit are as follows.
    SR1201 ETIF CAU-D: UTP CTG5 ST CA-N, UTP CTG5 ST CA-J
    SR1201 ETIF CAU-DD: UTP CTG5 ST CA-L, UTP CTG5 ST CA-J, UTP CTG5 CRS CA-F
    Note 2:The cables cited in Figure 4-16 can be used in the 1-IMG system only. Refer to Page 45 through Pa g e  4 8
    for more details.
    Figure 4-16   Examples of Ethernet Cable Connection-FCH in PIM3 (1-IMG System) (1/2)Configuration
    of CPUConfiguration
    of LANUsed Cable Unit
    (Note 1, Note 2)Number of  HUB/
    FCH
    Pattern 1 Single Single SR1201 ETIF CAU-D × 1 HUB× 1, FCH× 1
    Pattern 2 Dual SingleSR1201 ETIF CAU-D × 1
    SR1201 ETIF CAU-DD × 1HUB× 2, FCH× 2
    Pattern 3 Single Dual SR1201 ETIF CAU-D × 2 HUB× 2, FCH× 2
    Pattern 4 Dual DualSR1201 ETIF CAU-D × 2
    SR1201 ETIF CAU-DD × 2HUB× 2, FCH× 2
    ATTENTIONContents
    Static Sensitive
    Handling
    Precautions Required
    06 04 05 03 02 01 0006 04 05 03 02 01 00
    CNCN
    HUB
    BASEU
    UTP CTG5 ST CA-J
    FANU
    BSCM
    FCH
    CN
    CN
    UTP CTG5 ST CA-N
    PIM 1
    PIM 2
    PIM 3
    PIM 0
    LPM
    TOPU
       
    06 04 05 03 02 01 00
    06 04 05 03 02 01 00
    CN
    CN
    CN
    CN
    UTP CTG5 ST CA-J
    CNFCH
    HUB
    CN
    CN
    HUB
    BASEU
    PIM 1
    PIM 2
    PIM 3
    LPM
    CN
    TOPU
    FANU
    PIM 0
    BSCM
    UTP CTG5 CRS CA-F
    CNFCH
    CN
    UTP CTG5 ST CA-N
    UTP CTG5 ST CA-L
    FCH (PA-FCHA)HUB (PA-M96)
    TP0-X TP1-X
    TP2-X TP3-X TP4-X TP5-X TP6-X TP7-X
    10 BASE-T
    Connectors for 10 BASE-T
    FRONT VIEWFRONT VIEW
    CN= 10  BASE-T Connector
    Use 10 BASE-T connectors.  
    						
    							ND-70185 (E) CHAPTER 4
    Page 55
    Revision 3.0
    INSTALLATION
    Connecting Cables
    Figure 4-16   Examples of Ethernet Cable Connection-FCH in PIM3 (1-IMG System) (2/2)
    ATTENTIONContents
    Static Sensitive
    Handling
    Precautions Required
    06 04 05 03 02 01 0006 04 05 03 02 01 00
    CN
    CNCN
    CN
    HUB
    CN
    CNHUB
    BASEU
    PIM 1
    PIM 2
    PIM 3
    UTP CTG5 ST CA-J
    PIM 0
    LPMFANU
    BSCM BSCM
    CN
    FCH
    CN
    UTP CTG5 ST CA-J
    FCH
    CN
    CN
    UTP CTG5 ST CA-N
    TOPU
    06 04 05 03 02 01 00
    06 04 05 03 02 01 00
    CN
    CN
    CN
    CNCN
    CNUTP CTG5 ST CA-J
    CN
    FC H
    HUB
    CN
    HUB
    BASEU
    PIM 1
    PIM 2
    PIM 3
    LPM
    CN
    CN
    FANU
    PIM 0
    CN
    FCH
    CN
    UTP CTG5 ST CA-N
    UTP CTG5 ST CA-L
    UTP CTG5 ST CA-J
    TOPU
       
    Note:When dual LANIs are used in both Slot 00 and 03 of CPR (Pattern 3 or 4), be sure to use at least two
    HUB cards: One HUB for internal LANI (in Slot 00) and the other for external LANI (in Slot 03).
    However, if this is the case and FCH is also in a dual configuration, the 10 BASE-T ”cross”
    connection between the HUBs is not required.  
    						