CHAPTER 5 ND-70185 (E) Page 96 Revision 3.0 DATA PROGRAMMING Assignment of FCH Related Data STEP 8: AFPC Assign the FCCS routing data. FPC: 1 (FPC of the adjacent node)FCCH: 1 (with FCCH) CRT: 10 FCHN: 2 STEP 9: ACAN Assign the CIC number to the connection trunk. FPC: 1 FCIC: 1-664 CLENS: LEN of the connection trunk STEP 10: AFCD Assign NAILED DOWN CONNECTION for the connection link established between FCCH and SDT. LENS-A: LEN of SDT EAD-A: 07 (pad off) LENS-B: LEN of FCCH EAD-B: 07 (pad off)
ND-70185 (E) CHAPTER 5 Page 97 Revision 3.0 DATA PROGRAMMING Assignment of FCH Related Data 7.3 FCCS Link via Internet/Intranet The system can exchange FCCS data via the Internet/Intranet. As shown below, an FCCS Link can be es- tablished by using the following features: External Router Fusion over IP 7.3.1 External Router This feature allows the system to exchange the FCCS data via the Internet/Ethernet. For this feature, an FCCS link is connected to an external router. Figure 5-39 External Router - Overview Figure 5-40 Hardware Connections for External Router Fusion Network Internet/ Intranet FCCS link FCCS signaling is exchanged via the Internet/Intranet. POWERPOWER Speech Data for Fusion Router Router Node A Node B Signaling data for Fusion HUB Speech ROUTER signaling CPUPBX FCHFCH FGHDTI HUBDTI DTI LANI (slot 00 / 03) LoopBack Fusion Network Internet/ Intranet10BASE-T ACRD ACTK AFCH AFPC ACANACRD ACTK AGIP AETH DTI: Digital Trunk Interface FCH: Fusion Control Handler (PA-FCHA) FGH: Fusion Gateway Handler (PA-FCHA) LANI: LAN Interface (PZ-PC19) POWER 1. Using two DTI cards, make a loop connection. 2. Mount FCH, FGH cards. Then, connect the DTI and FCH/FGH cards, respectively, by using the front cable. 3. Connect two LANI cards and HUB cards, respectively.
CHAPTER 5 ND-70185 (E) Page 98 Revision 3.0 DATA PROGRAMMING Assignment of FCH Related Data STEP 1: ACRD Assign Route Class Data of Speech Route, FCH, FGH routes, respectively. A sample data assignment is shown below. See 6.1 Assignment of Connection Route/Trunk Data for more detailed information. Figure 5-41 Connection Route Class Data Sample FGHFCCH Speech 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16FGHTF TCL RLP SMDR LSG PA D TRKS TC/EC FINT FPEG TC MTC STSEQ MMN LKIND3 4 2 0 12 0(1) 0 0 0 0 2 03 4 2 0 13 0 0 0 03 4 2 0 13 0 0 0 0 0 0 0 0 0FCCH 3 4 2 0 13 0 0 0 0 0 0 0 00 0 0 1 RT 1011 1514 Sample Data Assignment CDNType ote: This data setting is an example. CPU PBX FCH FCH FGHDTI HUBHUB DTI DTI LANI Speech Signal ROUTER RT14 RT15 RT11 RT10 External LAN Internal LAN Fusion Network MDF
ND-70185 (E) CHAPTER 5 Page 99 Revision 3.0 DATA PROGRAMMING Assignment of FCH Related Data STEP 2: ACTK Assign the connection trunk data of DTI, FCH, and FGH cards, using the ACTK command. When assigning FCH, FGH trunk data, eight trunks must be set. A sample data assignment of FCH, FGH card is as follows. Figure 5-42 Sample Data Assignment (ACTK) PWR PWR FCH(RT14) FGH(RT15)C_RT C_TKC_LENS 14 14 14 14 14 14 14 14 (1-1023) (1-4095)MG U G L 00-07 0-3 00-23 0-7 0 1 2 3 4 5 6 7 1 2 3 4 5 6 7 803 000 03 000 03 000 03 000 03 000 03 000 03 000 03 000 15 15 15 15 15 15 15 150 1 2 3 4 5 6 7 1 2 3 4 5 6 7 815 001 15 001 15 001 15 001 15 001 15 001 15 001 15 001 When FCH and FGH cards are mounted in the following slots with the specified RT numbers, data setting is as follows. FCH(RT14) FGH(RT15) slot05 slot21 PWR PWR 00 0102 0304 0506 0708 0910 1112 13 14 1516 17 18 1920 21 22 2300 0102 0304 0506 0708 0910 1112 13 14 1516 17 18 1920 21 22 23 LV 0 slot05 slot21 LV 7
CHAPTER 5 ND-70185 (E) Page 100 Revision 3.0 DATA PROGRAMMING Assignment of FCH Related Data STEP 3: AFCH Assign FCH number on an FCH circuit card basis. In the following example, FCHN=1 is assigned for the FCH circuit card. For the FGH card, FCHN assignment is not necessary. Figure 5-43 Assignment of FCHN (Example) STEP 4: AGIP Assign IP addresses of FGH card and its connected router. FCHEN (FCH Equipment Number): Assign LV0 data of FGH LENs. FGH_IP (FGH IP Address): Assign IP address of the FGH card. DG_IP (Default Gateway IP address): Assign IP address of the router. ARP (ARP Frame Type): Assign 2 (=DIX spec.). CONTTYP (Voice Channel Control Type): Assign 1 (=Server). LINK_NUM (Qsig-Prime Link Number) : Assign the number (1-32) of interfaces for speech (=total DTI card number). CSLINK_NUM (Client /Server Connection Max. Number): Assign 0. FCHN 1 FCHEN 000030 AFCH command display Note 1 Note 1 : This setting is a sample. Note 2: This card cannot be used as a CCIS #7 signaling channel. CPU PBX LANIFCH FCH FGHDTI HUBHUB DTI DTI Signal ROUTER RT14 RT15 RT11 RT10 External LAN Internal LAN Fusion Network MDF Speech FCHN=1 FCHEN: 000030 IP address: aaa.aaa.aaa.a IP address: xxx.xxx.xxx.x Note 2
ND-70185 (E) CHAPTER 5 Page 101 Revision 3.0 DATA PROGRAMMING Assignment of FCH Related Data STEP 5: AFPC Assign internal LAN routing data. FPC (Fusion Point Code): Assign FPC number (1-253) of the Destination Node. FCCH: Assign 1. C_RT (Connection Router): 1-1023 FCHN/FPCN (FCH/FPC Number): Assign the FCH Number, specified in STEP 3. USE_GATE: Assign 1 (=Gateway function is used). P_ROUTE (Priority Route): 0/1 = FCH/FGH Example data assignment is shown in Figure 5-44 and Figure 5-45: Figure 5-44 Sample Data Assignment (AFPC) Figure 5-45 Internal LAN Routing Data Assignment Image (Example) FPC FCCH 1 C_RT FCHN (FCH Number) USE_GATE P_ROUTEFCCH USE_GATE P_ROUTE 12 CNT 10 10 1110 1 11 1111 11 FPC FCCH 1 C_RT FCHN (FCH Number) 12 CNT 10 1 A total of 8 routings (CNT=1 - 8) must be assigned. When alternative routing is not required, assign the same routing data for each CNT. 11 12 FPC=11FPC=10FPC=12 FCHFCHFCH Internet/ Intranet POWERPOWERPOWER Router RouterRouter FGH aaa.aaa.aaa.abbb.bbb.bbb.b FGH ccc.ccc.ccc.c FGH speech FCHN=1 self-Node C_RT=10
CHAPTER 5 ND-70185 (E) Page 102 Revision 3.0 DATA PROGRAMMING Assignment of FCH Related Data STEP 6: AETH Assign the external router routing data. FPC (Fusion Point Code): Assign FPC number (1-253) of the Destination Node. USE_GATE: Assign 1 (=use Gateway). FCHN (FCH Number): Assign the FCH Number, specified in STEP 3. C_RT (Connection Route): 1-1023 DST_IP (Destination IP Address): Assign FGH IP address of the Destination Node. NEXT_IP (Next IP Address): Assign FGH IP address of the Next Node (Node to be passed to). Example data assignment is shown in Figure 5-46 and Figure 5-47. Figure 5-46 Sample Data Assignment (AETH) Figure 5-47 How to Assign Destination IP and Next IP A maximum of 8 routings are available. FPCUSE_GATE 1 C_RT FCHN (FCH Number) DST_IP NEXT_IP 12 CNT bbb.bbb.bbb.b 10 1 bbb.bbb.bbb.b FPCUSE_GATE 1 C_RT FCHN (FCH Number) DST_IP NEXT_IP 12 CNT bbb.bbb.bbb.b 10 1 ccc.ccc.ccc.c 11 12 FPC=11FPC=10FPC=12 FCHFCHFCH C_RT=10 Internet/ Intranet POWERPOWERPOWER Router RouterRouter FGH aaa.aaa.aaa.abbb.bbb.bbb.b FGH ccc.ccc.ccc.c FGH NEXT_IPDST_IP Destination IP Next IP Destination Node does not change. Address of Node to be passed to. NEXT_IP NEXT_IP DST_IP DST_IP destintaion information embedded in the packet bbb.bbb.bbb.b ccc.ccc.ccc.c NEXT_IP DST_IP ccc.ccc.ccc.cccc.ccc.ccc.c speech FCH=1
ND-70185 (E) CHAPTER 5 Page 103 Revision 3.0 DATA PROGRAMMING Assignment of FCH Related Data STEP 7: ACAN Assign the Fusion Connection Index Code (FCIC) for the Next Node. FPC (Fusion Point Code): Assign FPC number of the Next Node (Node to be passed to). FCIC (Fusion Connection Index Code): Assign Fusion CIC of the Next Node (Node to be passed to). C_LENS (Connection_LENS): Assign DTI LENS data (Bch data), specified in STEP 2. Figure 5-48 Sample Data Assignment (ACAN) STEP 8: MBCT Unbusy the connection trunk data assigned in the previous steps, by using the MBCT command, This is required for FCH, FGH trunks as well as speech channels. FPC FCIC11 1 C_LENS 002010 Note ACAN command parameters Note: This setting is a sample. FPC (Next Node) CPU PBX FCH FCH FGHDTI HUBHUB DTI DTI LANI Signal ROUTER RT14 RT15 RT11 RT10 External LAN Internal LAN MDFFCHN=1 FCHEN: 000030 FCHN is not required for FGH speechFCIC1: 002010 FCIC2: 002011 FCIC3: 002012 FCIC10: 002022 SpeechFusion Network
CHAPTER 5 ND-70185 (E) Page 104 Revision 3.0 DATA PROGRAMMING Assignment of FCH Related Data 7.3.2 FCCS Networking over IP This feature allows the system to exchange both speech and FCCS signaling over Internet/Intranet. To establish/release a call, Q-sig is used between the system and the router. H.323 is used as a protocol be- tween routers. Figure 5-49 FCCS Networking over IP - Overview Figure 5-50 Hardware Connections for FCCS Networking over IP POWERInternet/ Intranet Speech Signaling PBXPBX RouterH.323 Router POWER Node ANode B Fusion network is realized via the Internet/Intranet. Speech Q-sig CPU PBX FCHFGHDTI LANIROUTER Nail Down Connection H.323 Protocol T1 signalingInternet/ Intranet The following circuit cards are required for this feature. DTI: Digital Trunk Interface FCH: Fusion Control Handler (PA-FCHA) FGH: Fusion Gateway Handler (PA-FCHA) LANI: LAN Interface (PZ-PC19)10 BASE-T (Slot 00/03)
ND-70185 (E) CHAPTER 5 Page 105 Revision 3.0 DATA PROGRAMMING Assignment of FCH Related Data STEP 1: ACRD Assign Route Class Data of Speech Route, FCH, FGH routes, respectively. A sample data assignment is shown below. Figure 5-51 Sample Data Assignment (ACRD) STEP 2: ACTK Assign the connection trunk data of DTI, FCH, and FGH cards, using the ACTK command. When assigning FCH, FGH trunk data, eight trunks must be set. A sample data assignment of FCH, FGH card is as follows. Figure 5-52 Sample Data Assignment (ACTK) Q-sig PBX FCH FGHDTI ROUTER Nail Down Connection T1 speech signaling FGHFCCH Speech 1 2 3 4 5 6 7 8 9 10 11 12 13 14 16 15FGHTF TCL RLP SMDR LSG PA D TRKS TC/EC FINT FPEG TC MTC STSEQ LKINDMMN3 4 2 0 12 0(1) 0 0 0 0 0 0 23 4 2 0 13 0 0 0 03 4 2 0 13 0 0 0 0 0 0 0 000 0 1 RT 113 14 CDNType RT13RT14RT1 to CPU Note: This data setting is an example. PWR PWR FCH(RT13) FGH(RT14)C_RT C_TKC_LENS 13 13 13 13 13 13 13 13 (1-1023) (1-4095)MG U G L 00-07 0-3 00-23 0-7 0 1 2 3 4 5 6 7 1 2 3 4 5 6 7 803 000 03 000 03 000 03 000 03 000 03 000 03 000 03 000 14 14 14 14 14 14 14 140 1 2 3 4 5 6 7 1 2 3 4 5 6 7 815 001 15 001 15 001 15 001 15 001 15 001 15 001 15 001 When FCH and FGH cards are mounted in the following slots with the specified RT numbers, data setteing is as follows: FCH(RT13) FGH(RT14) slot05 slot21 PWR PWR 00 0102 0304 0506 0708 0910 1112 13 14 1516 17 18 1920 21 22 2300 0102 0304 0506 0708 0910 1112 13 14 1516 17 18 1920 21 22 23 LV 0 slot05 slot21 LV 7