NEC Neax 2400 Imx Fusion Network System Manual
Have a look at the manual NEC Neax 2400 Imx Fusion Network System Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 1168 NEC manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
CHAPTER 7 ND-70185 (E) Page 156 Revision 3.0 TROUBLESHOOTING 23-S FCH Failure Notification (Detection) 7.1 Repair Procedure STEP 1: Make sure that the related Ethernet cables are securely inserted into the connectors. (See the example shown below.) If not, securely insert the cable. In this instance, confirm whether System Message 23- T FCH Fault Recovery Notification is displayed as the result of cable insertion. If no fault is found in this step, move to STEP 2. STEP 2: The following equipment is suspected to be faulty. Check for each item: Ethernet cables (10 BASE-T cables) ← See Figure 7-13 “How to Check 10 BASE-T cables.” HUB (PA-M96) ← See Figure 7-14 “How to Replace HUB (PA-M96) card.” FCH (PA-FCHA) ← See Figure 7-4 “How to Replace FCH (PA-FCHA) card.” Figure 7-12 10 BASE-T Cable Connection Check PIM 0 PIM 1 HUB ATTENTIONContents Static Sensitive Handling Precautions Required LANI DTI DTI (PA-M96) LANI FCH card indicated by system message (PA-M96)HUB FCH (PA-FCHA) Note: 10 BASE-T cable connections may differ depending on system configuration.: 10 BASE-T cable
ND-70185 (E) CHAPTER 7Page 157 Revision 3.0 TROUBLESHOOTING 23-S FCH Failure Notification (Detection) Figure 7-13 How to Check 10 BASE-T Cables WARNING: When a HUB card is placed in make-busy, all BASE-T interfaces connected to the HUB card become inoperative. ATTENTIONContents Static Sensitive Handling Precautions Required 2 MBOPE 10 BASE-T : 10 BASE-T cable Unplug and plug the modular connector MB MB HUB-HUB Cable Connection Test 1) Turn ON the MNT switch of the FCH cards which are connected to the both HUB cards. 2) Make sure that system message (23-W) FCH Alternate Routing (start) is displayed for each FCH. 3) Turn ON the MB key on the both HUB cards. 4) Unplug and plug the modular connector a few times at each conne- ctor since the connection may be a poor contact. 5) If the above procedure does not result in normal operation, perform \ the conductive test of the 10 BASE-T cable. HUB-LANI Cable Connection Test 1) Turn ON the MNT3 switch of the FCH cards which are connected to the both HUB cards. 2) Make sure that system message (23-W) FCH Alternate Routing (star\ t) is displayed for each FCH. 3) Turn ON the MB key on the HUB card. 4) Unplug and plug the modular connector a few times at each connector since the connection may be a poor contact. 5) If the above procedure does not result in normal operation, perform \ the conductive test of the 10 BASE-T cable. HUB - FCH Cable Connection Test 1) Turn ON the MNT 3 switch on the FCH card. (make-busy-request) 2) Make sure that system message (23-W) FCH Alternate Routing (start) is displayed. 3) Turn ON the MB key on the FCH card.(make-busy) 4) Turn ON the MB key on the HUB card.(make-busy) 5) Unplug and plug the modular connector a few times at each connector since the connection may be a poor contact. 6) If the above procedure does not result in normal operation, perform the conductive test of the 10 BASE-T cable. modular connector modular connector HUB (PA-M96) HUB (PA-M96) FCH (PA-FCHA)DTI(PA-24DTR)MNT 3 MNT to LANI (PZ-PC19) A B B C C A MB MB
CHAPTER 7 ND-70185 (E) Page 158 Revision 3.0 TROUBLESHOOTING 23-S FCH Failure Notification (Detection)Figure 7-14 How to Replace HUB (PA-M96) Card W ARNING: When a H UB ca rd is pl aced in make-bu sy, a ll BASE-T i nte rfaces conn ected to t he HUB card become inoperative. ATTENTIONContents Static Sensitive Handling Precautions Required 2 MB Anti-static Kit OPE 10 BASE-T HUB MB key operation 2 MBOPE 10 BASE-T HUB MB MB : 10 BASE-T cable When this MB key is set in up position (Make-busy), all 10 BASE-T interfaces connected to this card become inoperative. 10 BASE-T Cable Disconnection MNT 3HUB(PA-M96)HUB(PA-M96) FCH(PA-FCHA)DTI (PA-24DTR) to LANI (PZ-PC19) [How to Replace HUB card] 1) Provide anti-static kit. 2) Turn ON the MNT3 switch of the FCH cards which are connected to the HUB card to be replaced. 3) Make sure that system message (23-W) FCH Alternate Routing (start) is displayed for the FCH cards. 4) Turn ON the MB key on the HUB card. (make-busy) 5) Disconnect the 10 BASE-T cables from the card. 6) Extract the HUB card from the slot. 7) Set key settings on the new HUB card. 8) Turn ON the MB key on the new HUB card. 9) Mount the new HUB card in the slot. 10) Turn OFF the MB key on the card.
ND-70185 (E) CHAPTER 7 Page 159 Revision 3.0 TROUBLESHOOTING 23-T FCH Fault Notification (Recovery) 8. 23-T FCH Fault Notification (Recovery) This message is displayed when the FCH (PA-FCHA) card that was detected as faulty is recovered. The message is displayed in the following format. Figure 7-15 23-T FCCH Fault Recovery Notification 1. xx0x xx00 0000 0000 2. 0000 0000 0000 0000......... MG UG FCH Mounting Location FCH Mounting Location MG: Module Group U: Unit (0-3) G: Group (00-23)FCH CKT No. Circuit Number of FCH (0 - 7) FLTINF: Fault Information FLTINF FLTINF = 01H: ETHER Controller Initial NG FLTINF = 02H: ETHER Link Failure Note: Note
CHAPTER 7 ND-70185 (E) Page 160 Revision 3.0 TROUBLESHOOTING 23-U FCH Status Information 9. 23-U FCH Status Information This message is displayed when the status change of FCH (PA-FCHA) card is detected, which includes “FCH Initial Setting Failure,” “ETHER Transfer Failure.” When this message is displayed, follow the procedure ex- plained on a fault information basis. The figure below shows the general format of this message. Figure 7-16 23-U FCCH Status Information 1. xx0x xxxx xxxx xxxx 2. xxxx xxxx xxxx xxxx......... MG U G FCH Mounting Location FCH Mounting Location MG: Module Group U: Unit (0-3) G: Group (00-23) FCH CKT No. Circuit Number of FCH (0 - 7) FLTINF: Fault Information FLTINF TRC RS b0 b7b0 b7b0 b7b0 b7b0 b7 : : : : DATA* DATA* * The contents vary depending on FLTINF. 0 Note 2 Note 1 Note 1:FLTINF (Fault Information) consists of the following: OOH: Initial Setting Failure Notification 18H Spanning Tree Abnormal Answer Notification 1DH ETHER Transfer Failure Notification 1EH Spanning Tree Generation End Notification 1FH Spanning Tree Generation Start Notification 85H Check Sum Verify Failure Notification Note 2:When TRC = 1, the subsequent data indicates “Date Information” + “Primitive Contents” * The detailed fault information is explained on the following pages.
ND-70185 (E) CHAPTER 7 Page 161 Revision 3.0 TROUBLESHOOTING 23-U FCH Status Information 9.1 FLTINF = 00H Initial Setting Failure This message is displayed when the Ethernet Controller Initial Setting ends in failure. The detailed information is indicated in the following format. Figure 7-17 23-U FCCH Status Notification - Initial Setting Failure ETHER Results 00H: Normal 01H: ETHER Controller Reset Impossible 03H: ETHER Controller Initial NG 02H: Configuration Error 04H: ETHER Controller Initial NG 1. xx 0x 00 xx xx xx xx xx 2. xx xx xx xx 0000 0000......... MG UG FCH Mounting Location FCH CKT No.TRC RS 00 MG: Module Group U: Unit (0-3) G: Group (0-23)TRC: Trace Confirmation Bit (0/1 = Status Notification / Primitive Trace) RS: Receive / Send Primitive Trace (not effective) FCH CKT No. = Circuit No. of FCH 00FLTINF: 00H = Initial Setting Failure HDLC ResultsHDLC Results: 00H = Normal ETHER ResultsETHER Results: See below. b7 b0b7 b0b7 b0b7 b0b7 b0 b7 b0 MAC Address of FCH b7 b0 b7 b0 Other Results: 00H = Normal Other Results : : : :6 Bytes Initial Setting Failure
CHAPTER 7 ND-70185 (E) Page 162 Revision 3.0 TROUBLESHOOTING 23-U FCH Status Information 9.2 FLTINF = 18H Spanning Tree Abnormal Answer This message is displayed when Spanning Tree Abnormal Answer is detected. The detailed information is indi- cated in the following format. Figure 7-18 23-U FCCH Status Notification - Spanning Tree Abnormal Answer MG UG FCH Mounting Location FCH CKT No.TRC RS 00 MG: Module Group U: Unit (0-3) G: Group (0-23)TRC: Trace Confirmation Bit (0/1 = Status Notification / Primitive Trace) RS: Receive / Send Primitive Trace (not effective) FCH CKT No. = Circuit No. of FCH 18FLTINF: 18H = Spanning Tree Abnormal Answer Notification b7 b0b7 b0b7 b0 b7 b0 b7 b0 : : : :32 Bytes Spanning Tree Abnormal Answer b7 b0 - 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 255 254 253 252 251 250 249 248 247 246 245 244 243 242 241 240 239 238 237 236 235 234 233 232........ ........ * Each bit represents abnormal FPC (Fusion Point Code). When 1 is set, the FPC has not been assigned. (Use the AFPC command.) Abnormal FPC Information 1. xx 0x 18 xx xx xx xx xx 2. xx xx xx xx xx xx xx xx 3. xx xx xx xx xx xx xx xx 4. xx xx xx xx xx xx xx xx 5. xx xx xx 00 0000 0000 6. 00 00 00 00 00 00 00 00
ND-70185 (E) CHAPTER 7 Page 163 Revision 3.0 TROUBLESHOOTING 23-U FCH Status Information 9.2.1 Repair Procedure A Fusion Point Code (FPC) is assigned using the AFPC command. If any FPC data has not been assigned properly, this message is displayed. Make sure that the indicated FPC data is properly assigned. See the sample below. Figure 7-19 Spanning Tree Abnormal Answer 12 self-Node Node B Node C Node D Node E Node F MAT Assign all nodes FPCs including nodes which are not directly connected. Node GNode H 11 Node I 222 2324 21 101 This FPC has not been assigned. Spanning Tree Abnormal FPC = 2l
CHAPTER 7 ND-70185 (E) Page 164 Revision 3.0 TROUBLESHOOTING 23-U FCH Status Information 9.3 FLTINF = 1DH ETHER Transfer Failure This message is displayed when an FCH card discards an abnormal Ethernet packet (i.e. abnormal IP address destination) that was received from other node on the network. Figure 7-20 23-U ETHER Transfer Failure 1. xx 0x 1D xx xx xx xx xx 2. xx xx xx xx xx xx xx xx 3. xx xx xx xx xx xx xx xx 4. xx xx xx xx xx xx xx xx 5. xx xx xx xx xx xx xx xx 6. xx xx xx xx xx xx xx xx 7. xx xx xx xx xx xx xx xx 8. xx 00 00 00 00 00 00 00 9. 00 00 00 00 00 00 00 00 MG UG FCH Mounting Location FCH CKT No.TRC RS 00 MG: Module Group U: Unit (0-3) G: Group (0-23)TRC: Trace Confirmation Bit (0/1 = Status Notification / Primitive Trace) RS: Receive / Send Primitive Trace (not effective) FCH CKT No. = Circuit No. of FCH 1DFLTINF: 1D H = ETHER Transfer Failure Notification Transfer Failure Status b7 b0b7 b0b7 b0b7 b0 Discarded IP Packet Information b7 b0 b7 b0 : : : :53 Bytes ETHER Transfer Failure IP Header Part: 42 Bytes IP User Part: 11 Bytes
ND-70185 (E) CHAPTER 7 Page 165 Revision 3.0 TROUBLESHOOTING 23-U FCH Status Information 9.4 FLTINF = 1EH Spanning Tree Generation End This message is displayed when Spanning Tree Generation is complete. The detailed information is indicated in the following format. Figure 7-21 23-U FCCH Status Notification - Spanning Tree Generation End 1. xx 0x 1E xx xx xx xx xx 2. xx xx xx xx xx xx xx xx 3. xx xx xx xx xx xx xx xx 4. xx xx xx xx xx xx xx xx 5. xx xx xx 00 0000 0000 6. 00 00 00 00 00 00 00 00 MG UG FCH Mounting Location FCH CKT No.TRC RS 00 MG: Module Group U: Unit (0-3) G: Group (0-23)TRC: Trace Confirmation Bit (0/1 = Status Notification / Primitive Trace) RS: Receive / Send Primitive Trace (not effective) FCH CKT No. = Circuit No. of FCH 1EFLTINF: 1EH = Spanning Tree Generation End Notification b7 b0b7 b0b7 b0 b7 b0 b7 b0 : : : :32 Bytes Spanning Tree Generation End b7b0 - 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 255 254 253 252 251 250 249 248 247 246 245 244 243 242 241 240 239 238 237 236 235 234 233 232 .............. ........ * Each bit represents FPC (Fusion Point Code). When 1 is set, the FPC has joined the spanning tree configuration. Spanning Tree Configuration Results