    							CHAPTER 7 ND-70185 (E)
    Page 156
    Revision 3.0
    TROUBLESHOOTING
    23-S FCH Failure Notification (Detection)
    7.1 Repair Procedure
    STEP 1: Make sure that the related Ethernet cables are securely inserted into the connectors. (See the example
    shown below.) If not, securely insert the cable. In this instance, confirm whether System Message 23-
    T FCH Fault Recovery Notification is displayed as the result of cable insertion. If no fault is found
    in this step, move to STEP 2.
    STEP 2: The following equipment is suspected to be faulty. Check for each item:
     Ethernet cables (10 BASE-T cables)
     ← See Figure 7-13 “How to Check 10 BASE-T cables.”
     HUB (PA-M96) 
    ← See Figure 7-14 “How to Replace HUB (PA-M96) card.”
     FCH (PA-FCHA) 
    ← See Figure 7-4 “How to Replace FCH (PA-FCHA) card.”
    Figure 7-12   10 BASE-T Cable Connection Check
    PIM 0 PIM 1
    HUB
    ATTENTIONContents
    Static Sensitive
    Handling
    Precautions Required
    LANI
    DTI
    
    DTI
    (PA-M96)
    LANI
    FCH card indicated 
    by system message
    (PA-M96)HUB
    FCH (PA-FCHA)
    Note:   10 BASE-T cable connections may differ depending on system configuration.: 10 BASE-T cable 
    						
    							ND-70185 (E) CHAPTER 7Page 157
    Revision 3.0
    TROUBLESHOOTING
    23-S FCH Failure Notification (Detection)
    Figure 7-13   How to Check 10 BASE-T Cables
    WARNING:
    When a HUB card is placed in make-busy, all BASE-T interfaces connected to the 
    HUB card become inoperative.
    ATTENTIONContents 
    Static Sensitive
    Handling
    Precautions  Required
    2
    MBOPE
    10 BASE-T
    : 10 BASE-T cable
    Unplug and plug the  modular connector
    MB MB
             HUB-HUB Cable Connection Test
    
    
     
    1) Turn ON the MNT switch of the FCH cards which are connected 
         to the both HUB cards. 
    
    2) Make sure that system message (23-W) FCH Alternate Routing  
        (start) is displayed for each FCH. 
    
    3) Turn ON the MB key on the both HUB cards. 
    
    4) Unplug and plug the modular connector a few times at each conne- 
        ctor since the connection may be a poor contact. 
    
    5) If the above procedure does not result in normal operation, perform \
     
        the conductive test of the 10 BASE-T cable. 
                  HUB-LANI Cable Connection Test 
    
     
    1) Turn ON the MNT3 switch of the FCH cards which are connected 
         to the both HUB cards. 
    
    2) Make sure that system message (23-W) FCH Alternate Routing (star\
    t) 
        is displayed for each FCH. 
    
    3) Turn ON the MB key on the HUB card. 
    
    4) Unplug and plug the modular connector a few times at each connector 
         since the connection may be a poor contact. 
    
    5) If the above procedure does not result in normal operation, perform \
    the  
         conductive test of the 10 BASE-T cable. 
                  HUB - FCH Cable Connection Test 
    
     
    1) Turn ON the MNT 3 switch on the FCH card. (make-busy-request)  
    2) Make sure that system message (23-W) FCH 
        Alternate Routing (start) is displayed. 
    3) Turn ON the MB key on the FCH card.(make-busy) 
    4) Turn ON the MB key on the HUB card.(make-busy) 
    5) Unplug and plug the modular connector a few 
        times at each connector since the connection may 
        be a poor contact.  
    6) If the above procedure does not result in normal operation, 
        perform the conductive test of  the 10 BASE-T cable.  
        
    
    modular 
    connector
    modular 
    
    connector
    HUB (PA-M96)
    HUB (PA-M96) FCH (PA-FCHA)DTI(PA-24DTR)MNT 3
    MNT
     to LANI 
    (PZ-PC19)
    A
    B
    B
    C
    C A
    MB
    MB 
    						
    							CHAPTER 7 ND-70185 (E) 
    Page 158
    Revision 3.0
    TROUBLESHOOTING 
    23-S FCH Failure Notification (Detection)Figure 7-14   How to Replace HUB (PA-M96) Card
    W ARNING:  
    When a H UB ca rd  is pl aced in make-bu sy, a ll BASE-T i nte rfaces conn ected  to  t he
    HUB card become inoperative.
    ATTENTIONContents 
    Static Sensitive
    Handling
    Precautions  Required
    2
    MB
    Anti-static Kit
    OPE
    10 BASE-T
    HUB
    MB key operation
    2
    MBOPE
    10 BASE-T HUB
    MB
    MB
    : 10 BASE-T cable
    When this MB key is set in up position 
    (Make-busy), all 10 BASE-T interfaces 
    connected to this card become  
    inoperative.
    10 BASE-T Cable Disconnection
    MNT 3HUB(PA-M96)HUB(PA-M96) FCH(PA-FCHA)DTI (PA-24DTR)
     to LANI  
    (PZ-PC19)
    [How to Replace HUB card]
    
    
     
    1) Provide anti-static kit. 
    2) Turn ON the MNT3 switch of the FCH cards which are connected 
         to the HUB card to be replaced. 
    3) Make sure that system message (23-W) FCH Alternate Routing 
        (start) is displayed for the FCH cards. 
    4) Turn ON the MB key on the HUB card. (make-busy) 
    5) Disconnect the 10 BASE-T cables from the card. 
    6) Extract the HUB card from the slot. 
    7) Set key settings on the new HUB card. 
    8) Turn ON the MB key on the new HUB card. 
    9) Mount the new HUB card in the slot. 
    10) Turn OFF the MB key on the card.  
    						
    							ND-70185 (E) CHAPTER 7
    Page 159
    Revision 3.0
    TROUBLESHOOTING
    23-T FCH Fault Notification (Recovery)
    8. 23-T FCH Fault Notification (Recovery)
    This message is displayed when the FCH (PA-FCHA) card that was detected as faulty is recovered. The message
    is displayed in the following format.
    Figure 7-15   23-T FCCH Fault Recovery Notification
    1. xx0x  xx00  0000  0000           2. 0000  0000  0000  0000.........
    MG
    UG
    FCH Mounting Location
    FCH Mounting Location
    MG: Module Group 
    U: Unit (0-3)
    G: Group (00-23)FCH CKT No.
    Circuit Number of FCH (0 - 7) FLTINF: Fault Information
    FLTINF
    FLTINF = 01H: ETHER Controller Initial NG
    FLTINF = 02H: ETHER Link Failure  Note:
    Note 
    						
    							CHAPTER 7 ND-70185 (E)
    Page 160
    Revision 3.0
    TROUBLESHOOTING
    23-U FCH Status Information
    9. 23-U FCH Status Information
    This message is displayed when the status change of FCH (PA-FCHA) card is detected, which includes “FCH
    Initial Setting Failure,” “ETHER Transfer Failure.” When this message is displayed, follow the procedure ex-
    plained on a fault information basis. The figure below shows the general format of this message.
    Figure 7-16   23-U FCCH Status Information
    1. xx0x  xxxx  xxxx  xxxx           2. xxxx  xxxx  xxxx  xxxx.........
    MG
    U
    G
    FCH Mounting Location
    FCH Mounting Location
    MG: Module Group 
    U: Unit (0-3)
    G: Group (00-23)
    FCH CKT No.
    Circuit Number of FCH (0 - 7) FLTINF: Fault Information
    FLTINF
    TRC RS
    b0 b7b0 b7b0 b7b0 b7b0 b7
    :
    :
    : :
    DATA* DATA*
    * The contents vary depending on FLTINF.
    0
    Note 2
      Note 1
    Note 1:FLTINF (Fault Information) consists of the following:
    OOH: Initial Setting Failure Notification
    18H Spanning Tree Abnormal Answer Notification
    1DH ETHER Transfer Failure Notification
    1EH Spanning Tree Generation End Notification
    1FH Spanning Tree Generation Start Notification
    85H Check Sum Verify Failure Notification
    Note 2:When TRC = 1, the subsequent data indicates “Date Information” + “Primitive Contents”
    * The detailed fault information is explained on the following pages. 
    						
    							ND-70185 (E) CHAPTER 7
    Page 161
    Revision 3.0
    TROUBLESHOOTING
    23-U FCH Status Information
    9.1 FLTINF = 00H Initial Setting Failure
    This message is displayed when the Ethernet Controller Initial Setting ends in failure. The detailed information
    is indicated in the following format.
    Figure 7-17   23-U FCCH Status Notification - Initial Setting Failure
    ETHER Results
    00H: Normal
    01H: ETHER Controller Reset Impossible 03H: ETHER Controller Initial NG
    02H: Configuration Error 04H: ETHER Controller Initial NG
    1. xx 0x  00 xx  xx xx  xx xx           2. xx xx    xx xx  0000  0000.........
    MG
    UG
    FCH Mounting Location
    FCH CKT No.TRC
    RS
    00
    MG: Module Group 
    U: Unit (0-3)
    G: Group (0-23)TRC: Trace Confirmation Bit
    (0/1 = Status Notification / Primitive Trace)
    RS: Receive / Send Primitive Trace (not effective)
    FCH CKT No. = Circuit No. of FCH
    
     00FLTINF: 00H = Initial Setting Failure
    HDLC ResultsHDLC Results: 00H = Normal
    ETHER ResultsETHER  Results:  See below.
    b7 b0b7 b0b7 b0b7 b0b7 b0
    b7 b0
    MAC Address of FCH
    b7 b0
    b7 b0
    Other Results: 00H = Normal
    Other Results
    : :
    : :6 Bytes
    Initial Setting Failure 
    						
    							CHAPTER 7 ND-70185 (E)
    Page 162
    Revision 3.0
    TROUBLESHOOTING
    23-U FCH Status Information
    9.2 FLTINF = 18H Spanning Tree Abnormal Answer
    This message is displayed when Spanning Tree Abnormal Answer is detected. The detailed information is indi-
    cated in the following format.
    Figure 7-18   23-U FCCH Status Notification - Spanning Tree Abnormal Answer
    MG
    UG
    FCH Mounting Location
    FCH CKT No.TRC
    RS
    00
    MG: Module Group 
    U: Unit (0-3)
    G: Group (0-23)TRC: Trace Confirmation Bit
    (0/1 = Status Notification / Primitive Trace)
    RS: Receive / Send Primitive Trace (not effective)
    FCH CKT No. = Circuit No. of FCH
    
     18FLTINF: 18H = Spanning Tree Abnormal
                             Answer Notification
    b7 b0b7 b0b7 b0
    b7 b0
    b7 b0
    : :
    : :32 Bytes
    Spanning Tree Abnormal Answer
    b7 b0
    - 1 2 3
    4 5 6 7
    8 9 10 11 12 13 14 15
    16 17 18 19 20 21 22 23
    255 254 253 252 251 250 249 248 247 246 245 244 243 242 241 240 239 238 237 236 235 234 233 232........
    ........
    * Each bit represents abnormal FPC (Fusion Point Code).  When 1 is set, 
       the FPC has not been assigned. (Use the AFPC command.)
    Abnormal FPC Information
    1. xx 0x  18 xx  xx xx  xx xx           2. xx xx    xx xx  xx xx  xx xx       3. xx xx   xx xx   xx xx     xx xx
    4. xx xx  xx xx   xx xx  xx xx           5. xx xx   xx 00  0000   0000       6. 00 00  00 00  00 00    00 00  
    						
    							ND-70185 (E) CHAPTER 7
    Page 163
    Revision 3.0
    TROUBLESHOOTING
    23-U FCH Status Information
    9.2.1 Repair Procedure
    A Fusion Point Code (FPC) is assigned using the AFPC command. If any FPC data has not been assigned
    properly, this message is displayed. Make sure that the indicated FPC data is properly assigned. See the
    sample below.
    Figure 7-19   Spanning Tree Abnormal Answer
    12
    
    
    
    self-Node
    Node B Node C
    Node D
    Node E
    Node F
    MAT Assign all nodes FPCs including nodes which are not directly connected.
    Node GNode H
    11
    Node I
    222
    2324
    21
    101
    This FPC has not
    been assigned.
    Spanning Tree 
    Abnormal FPC = 2l 
    						
    							CHAPTER 7 ND-70185 (E)
    Page 164
    Revision 3.0
    TROUBLESHOOTING
    23-U FCH Status Information
    9.3 FLTINF = 1DH ETHER Transfer Failure
    This message is displayed when an FCH card discards an abnormal Ethernet packet (i.e. abnormal IP address
    destination) that was received from other node on the network.
    Figure 7-20   23-U ETHER Transfer Failure
    1. xx 0x  1D xx  xx xx  xx xx           2. xx xx    xx xx    xx xx   xx xx     3. xx xx   xx xx    xx xx    xx xx
    4. xx xx  xx  xx  xx xx  xx xx           5. xx xx    xx xx    xx xx   xx xx     6. xx xx   xx xx    xx xx    xx xx
    7. xx xx  xx  xx  xx xx  xx xx           8. xx 00    00 00   00 00  00 00    9. 00 00  00 00   00 00    00 00
    MG
    UG
    FCH Mounting Location
    FCH CKT No.TRC
    RS
    00
    MG: Module Group 
    U: Unit (0-3)
    G: Group (0-23)TRC: Trace Confirmation Bit
    (0/1 = Status Notification / Primitive Trace)
    RS: Receive / Send Primitive Trace (not effective)
    FCH CKT No. = Circuit No. of FCH
    
     1DFLTINF: 1D H = ETHER Transfer Failure Notification
    Transfer Failure Status
    b7 b0b7 b0b7 b0b7 b0
    Discarded IP Packet Information
    b7 b0
    b7 b0
    : :
    : :53 Bytes
    ETHER Transfer Failure
    IP Header Part: 42 Bytes
    IP User Part:     11 Bytes 
    						
    							ND-70185 (E) CHAPTER 7
    Page 165
    Revision 3.0
    TROUBLESHOOTING
    23-U FCH Status Information
    9.4 FLTINF = 1EH Spanning Tree Generation End
    This message is displayed when Spanning Tree Generation is complete. The detailed information is indicated
    in the following format.
    Figure 7-21   23-U FCCH Status Notification - Spanning Tree Generation End
    1. xx 0x  1E xx  xx xx  xx xx           2. xx xx    xx xx  xx xx  xx xx       3. xx xx   xx xx   xx xx     xx xx
    4. xx xx  xx xx   xx xx  xx xx           5. xx xx   xx 00  0000   0000       6. 00 00  00 00  00 00    00 00 
    MG
    UG
    FCH Mounting Location
    FCH CKT No.TRC
    RS
    00
    MG: Module Group 
    U: Unit (0-3)
    G: Group (0-23)TRC: Trace Confirmation Bit
    (0/1 = Status Notification / Primitive Trace)
    RS: Receive / Send Primitive Trace (not effective)
    FCH CKT No. = Circuit No. of FCH
    
     1EFLTINF: 1EH = Spanning Tree Generation          
                              End Notification
    b7 b0b7 b0b7 b0
    b7 b0
    b7 b0
    : :
    : :32 Bytes
    Spanning Tree  Generation End
    b7b0
    - 1 2 3 4 5 6 7
    8 9 10 11 12 13 14 15
    16  17 18 19 20 21 22 23
    255 254 253 252 251 250 249 248 247 246 245 244 243 242 241 240 239 238 237 236 235 234 233 232 ..............
    ........
    * Each bit represents FPC (Fusion Point Code).  When 1 is set, 
       the FPC has joined the spanning tree configuration.
    Spanning Tree Configuration Results 
    						