Home > NEC > Communications System > NEC Neax 2400 Imx Fusion Network System Manual

NEC Neax 2400 Imx Fusion Network System Manual

    Download as PDF Print this page Share this page

    Have a look at the manual NEC Neax 2400 Imx Fusion Network System Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 1168 NEC manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							CHAPTER 8 ND-70185 (E)
    Page 196
    Revision 3.0
    EX- FCCS
    Data Programming
    2. To Access EX-FCCS Trunk via EX-FCCS Telephone Number
    Assign the following data at NCN of the FUG.
    STEP 1: AEADN
    Assign the ADC (Abbreviate Digit Code) for connection Fusion Group. Enter the FUG Number as-
    signed by AFUGN command, TN, and ADC to be assigned.
    STEP 2: AELGN
    Telephone Numbers must be assigned for all the station within the network uniquely. Use AELGN
    command to allocate EX-FCCS Telephone Number. FUG data must be assigned previously by
    AFUGN command to activate this command.
    Only readout function can be used by this command in case both the Self FUG Number and the Con-
    nection FUG Number are assigned, if the Self FUG is not the Center FUG.
    Note 1:Check whether the trunk originating call via CCIS can be executed by dialing EX-FCCS Telephone Number
    here. Reexamine the assigned data if the call cannot be connected. There may be some error in data setting
    so far.
    Note 2:Refer to the service feature manual for NEAX2000 IVS2 system as to the data programming on NEAX2000
    IVS2 side.
    4.2.3 Upgrading CCIS Network including IVS2 System to EX-FCCS Network
    Enhanced
    FUG1 FUG2
    FUG3
    CCIS
    CCISCCISCCISIVS   System
    IVS   System PC1 PC2
    PC3
    PC4
    PC5 IMX
    IMXIMX
    NCN1 NCN2
    NCN3(Center FUG)
    2
    2
    CCIS
    Enhanced
    CCISEnhanced
    CCIS
    Enhanced
    CCIS 
    						
    							ND-70185 (E) CHAPTER 8
    Page 197
    Revision 3.0
    EX- FCCS
    Data Programming
    1. To Log-in to All Nodes in EX-FCCS Network
    To upgrade CCIS network to EX-FCCS Network as shown in the figure on the previous page, all the IMX sys-
    tems are set as NCNs respectively. To construct a EX-FCCS Network including stand-alone IMX system, the
    node must be assigned as a Fusion Network configured by the NCN only, and handled by the NDM data. Assign
    the following data at all the NCNs (that is, all the IMX systems of each node) within the EX-FCCS Network.
    STEP 1: AFUGN
    Assign EX-FCCS Fusion Group data such as Self FUG Number and connection FUG Number des-
    ignating Fusion Point Code of the NCN within FUG. Assign one of the IMX systems as the Center
    Fusion Group by clicking the check box in the “CENTER” parameter.
    STEP 2: AEXFN
    Assign the CCH Selection Data by designating all the Fusion Point Code (FPC) and the Point Code
    (PC) in the connected Fusion Group.
    Note:Confirm the Centralized MAT can log in to each node here. Reexamine the assigned data if log-in can not
    be executed. There may be some error in data setting so far.
    2. To Access to EX-FCCS Trunk via EX-FCCS Telephone Number
    Assign the following data to activate originating calls via EX-FCCS trunk. EX-FCCS Abbreviated Digit Code
    (ADC) must be assigned by using AEADN command at all the IMX nodes in the network. Only at the NCN of
    the Center Fusion Group, allocate EX-FCCS Telephone Numbers for all the stations in the network uniquely.
    AEADN: Assign the ADC (Abbreviate Digit Code) for connection Fusion Group. Enter the FUG Number as-
    signed by AFUGN command, TN, and ADC to be assigned.
    AELGN: Telephone Numbers must be assigned for all the station within the network uniquely. Use AELGN
    command to allocate EX-FCCS Telephone Number. FUG data must be assigned previously by
    AFUGN command to activate this command.
    Only readout function can be used by this command in case both the Self FUG Number and the Con-
    nection FUG Number are assigned, if the Self FUG is not the Center FUG.
    Note 1:Refer to the service feature manual for NEAX2000 IVS2 system as to the data programming on NEAX2000
    IVS2 side.
    Note 2:Check whether the trunk originating call via CCIS can be executed by dialing EX-FCCS Telephone Number
    here. Reexamine the assigned numbering plan data if the call cannot be connected. There may be some er-
    ror in the data setting so far.
    
     
    						
    							CHAPTER 8 ND-70185 (E)
    Page 198
    Revision 3.0
    This page is for your notes. 
    						
    All NEC manuals Comments (0)

    Related Manuals for NEC Neax 2400 Imx Fusion Network System Manual