    							CHAPTER 5 ND-70185 (E)
    Page 126
    Revision 3.0
    DATA PROGRAMMING
    Office Data Sheets
    FUSION POINT CODE 
    (FPC)
    1-253FCCH USE OR
    NOT USE (FCCH)
    0/1
    12345678
    CONNECTION ROUTE
    (C_RT)
    1-1023
    FCCH NUMBER/FUSION
    POINT CODE NUMBER
    (FCHN/FPCN) 1-255/1-253 
    						
    							ND-70185 (E) CHAPTER 5
    Page 127
    Revision 3.0
    DATA PROGRAMMING
    Office Data Sheets
    8.13 Data Sheet for ACAN
    FUSION POINT CODE 
    (FPC)
    1-253FUSION CIC NUMBER 
    (FCIC)
    1-4095CONNECTION EQUIPMENT 
    NUMBER 
    (C_LENS)REMARKS 
    						
    							CHAPTER 5 ND-70185 (E)
    Page 128
    Revision 3.0
    DATA PROGRAMMING
    Office Data Sheets
    8.14 Data Sheet for AFRT
    FCCH NUMBER 
    (FCHN)
    1-255CONNECTION ROUTE (C_RT) 1-1023
    12345678 
    						
    							ND-70185 (E) CHAPTER 5
    Page 129
    Revision 3.0
    DATA PROGRAMMING
    Office Data Sheets
    8.15 Data Sheet for AETH
    DESTINATION 
    FPC
    (FPC)
    1-253GATEWAY
    USING FLAG
    (USE_GATE)
    0/1FCCH
    NUMBER
    (FCHN)
    1-255CONNECTION 
    ROUTE
    (C_RT)
    1-1023DESTINATION
    IP ADDRESS
    (DST_IP)NEXT IP
    ADDRESS
    (NEXT_IP) 
    						
    							CHAPTER 5 ND-70185 (E)
    Page 130
    Revision 3.0
    DATA PROGRAMMING
    Office Data Sheets
    8.16 Data Sheet for AGIP
    LINE EQUIPMENT
    NUMBER OF FCCH
    (FCHEN)FGH IP
    ADDRESS
    (FGH_IP)IP ADDRESS
    FOR DEFAULT
    GATEWAY
    (DG_IP)FRAME
    TYPE OF
    ARP
    (ARP)
    1/2VO I C E  
    CHANNEL
    CONTROL
    TYPE
    (CONTTYP)
    0/1QSIG-PRIME
    LINK NUMBER
    (LINK_NUM)
    0-32CLIENT/
    SERVER
    CONNECTION
    MAX. NUMBER
    (CSLINK_NUM)
    0-15 MG U G LV 
    						
    							ND-70185 (E) CHAPTER 5
    Page 131
    Revision 3.0
    DATA PROGRAMMING
    Office Data Sheets
    8.17 Data Sheet for AFIP
    FCH
    NUMBER
    (FCHN)LINE EQUIPMENT
    NUMBER OF FGH
    (FGHEN)LINE EQUIPMENT
    NUMBER OF
    QSIG-PRIME Bch
    (LENS)ROUTER ACCESS NUMBER
    (RT_ACC)
    Max. 16 digits
    MG U G LV MG U G LV 
    						
    							CHAPTER 5 ND-70185 (E)
    Page 132
    Revision 3.0
    DATA PROGRAMMING
    Office Data Sheets
    8.18 Data Sheet for AFRFL
    TN FPC (1-253)AC C
    MAX. 24 digits 
    						
    							ND-70185 (E) CHAPTER 6
    Page 133
    Revision 3.0
    CHAPTER 6 POST INSTALLATION TEST
    This chapter covers how to perform installation tests focusing on the Fusion Call Control Signal (denoted in the
    remainder of this manual as FCCS) connections, after hardware installation and data assignment. This chapter
    describes the following tests:
     How to Check Fusion Link by LEDs on an FCH Card
     Repair Procedure When LED Indicates Abnormality
     FCCS Network Connection Test
     FCCS Alternate Routing Test
     Fusion and Non-Fusion Connection Test
    At the end of this chapter, the Fusion Link Test Sheet is attached. Make photo-copies of the sheet to record the
    test results. 
    In this chapter, explanations are given using the following network numbering as an example.
    Figure 6-1   Fusion Network
    Note:
    The Individual Trunk Access feature is not available for Fusion Trunks. To seize a specific Fusion Trunk,
    use the MBCT command to make busy trunks which are not being tested. This command leaves the Fusion
    trunk to be tested in an idle state.
    1. How to Check Fusion Link by LEDs on FCH Card
    Before performing the Fusion link test, be sure to check the Fusion Link LEDs. Refer to Figure 6-2. When the
    Fusion link is established, the LYR lamp lights green on the FCH (PA-FCHA) circuit card. However, if it re-
    mains off, the layer 2 (Link Layer) is not established. If this is the case, follow the repair procedure listed here.
    
    
    ............................................................
    
    
    ............................................................FCCS
    TELN: 410000
    STN: 2000
    
    FCCS: Fusion Call Control Signal     STN: Physical Station Number    TELN: Telephone Number
    TELN: 420000
    STN: 2000
    Fusion Link
    FUSION Network NodeA
    (self-Node)STNB NodeB
    (other Node)
    STNA
    Node A
    Node B 
    						
    							CHAPTER 6 ND-70185 (E)
    Page 134
    Revision 3.0
    POST INSTALLATION TEST
    Repair Procedure When LED Indicates Abnormality
    1.1 How to check LYR LED
    1. Confirm the LYR LED lights green on the front edge of the FCH (PA-FCHA) circuit card. (See “LED
    Indication (A)” in Figure 6-2.) When the LED lights green, the fusion link is established.
    2. Make sure that any alarm LED is not ON (red/yellow). (See LED Indication (B) in Figure 6-2.)
    When all alarm LEDs are OFF, the DTI (PA-24DTR) card is in normal operation.
    If any abnormal state is detected, please see the NEAX2400 IMX Circuit Card Manual.
    Figure 6-2   LED Indications on Fusion Link Related Circuit Cards
    2. Repair Procedure When LED Indicates Abnormality
    If the LED indication appears abnormal, check the following items again:
    2.1 Front Cable
    Make sure that front cable 10AL (10) FLT CA is securely inserted into the connectors.
    LYR
    LB
    LOADEST3
    EST2
    EST1
    EST0
    Payload
    Line
    Internal
    ON
    8
    OPEOPE
    Mode
    PCM
    FRM
    BER
    RMT
    AIS
    LED Indication  (A)
    LED Indication (B)
    DTI
    FCH
    
    Front Cable
    LYR
    LB
    LOAD
    EST3
    EST2
    EST1
    EST0Remains ON
    when available
    for Ethernet
    Remains ON
    when ready to broadcast
    data packets     
    Note
    Link is
    established Receive Receive Polarity of
    pairwire is normalSend
    PA-FCHA
    DTI
    PA-24DTR
    Remains ON
    when Fusion Link 
    is established
    PCM : On when PCM loss occurs.
    FRM : On when Frame Loss occurs.
    BER  : On when Bit Error occurs.
    RMT : On when Remote Alarm is received.
    AIS   : On when AIS signal is detected.
    
    If any LED is ON, refer to the Circuit
    Card Manual.
    FCH
    FRONT
    Note:When the FCH is a Root Bridge, the LOAD LED remains ON.
    When the FCH is Backup Bridge, the LOAD LED flashes (60INT). 
    						
    							ND-70185 (E) CHAPTER 6
    Page 135
    Revision 3.0
    POST INSTALLATION TEST
    Repair Procedure When LED Indicates Abnormality
     FCH (PA-FCHA) switch setting
    Make sure that the following keys are set properly:
     Dch TS designation (0ch - 23ch: SW11, SW12, SW13)
     Data Link Signal Logic (positive/negative: SW14-1)
     Fusion Data Link Speed (48/56/64 kbps: SW14-2, 3)
     LAPD Signal Link (user/network: SW14-4)
     24DTI (PA-24DTR) switch setting
    Make sure that the keys are properly set on the card. See the NEAX2400 IMX Circuit Card Manual.
    If the Fusion link is not established using this repair procedure, perform the Fusion Link Test.
    2.2 How to Perform the Fusion Link Test
    2.2.1 Fusion Link Test Mode Setting
    To set the FCH card in Fusion Link Test Mode, set the Mode Switch to 9. Initialize the FCH card using
    the MB key. When the Mode is 9, the Fusion Link Controller on the FCH card sends a test data pattern.
    When the same pattern is received again the PM activates the LYR LED, flashing the LED at 60-INT,
    which means the test result is OK.
    Figure 6-3   Fusion Link Test Mode
    Note:
    Be sure to initialize the FCH (PA-FCHA) card, after changing the setting of the Mode Switch.
    2.2.2 Loopback Point Designation
    The DTI card can be set at one of the following loopback points:
    1. Internal Loopback
    Note:Loopback points are set by a DTI card.
    9Mode LYR9: Fusion Link Test Mode
    8: Standard SettingFCH cardto DTI cardTest is OKLYR LED flashes.
    FCH
    front cable
    Flow of TestPA-
    FCHA
      Send Test 
    Data Pattern
    Receive Test 
    Data Pattern
    FRONT VIEW
    Fusion Link Controller sends test data pattern.
    DTI Interface
    D/I
    Fusion Link 
     Controller
    LoopbackNote To perform a Fusion link test, set the Mode switch to 9. 
    						