Page 91
CHAPTER 5 ND-70185 (E) Page 76 Revision 3.0 DATA PROGRAMMING Assignment of Telephone Numbers STEP 2: ACTK Assign the connection trunk data of both B-channel and D-channel using the ACTK command. As- sign the Connection Equipment Number (C_LENS) referring to Figure 5-22 through Figure 5-25. The ACTK command display should look similar to the following. Figure 5-22 ACTK Command Display (example) The mounting location of the FCH, DTI cards can be classified into the following two types. Regular Density...
Page 92
ND-70185 (E) CHAPTER 5 Page 77 Revision 3.0 DATA PROGRAMMING Assignment of Telephone Numbers Table 5-2 Data Programming Sheet for Regular Density Slot C_RT (1-1023)C_TK(1-4095)C_LENS Time Slot Allocation MG U G LV 10 (B-ch)1 000010 2000011 3000012 4000013 5000014 6000015 7000016 8000017 9000020 10000021 11000022 12000023 13000024 14000025 15000026 16000027 17000030 18000031 19000032 20000033 21000034 22000035 23000036 11 (D-ch)1000037 2000270 0405 01 2703 00 02Dch (TK1) Bch (TK23) Bch (TK1) Dch (TK2) Bch...
Page 93
CHAPTER 5 ND-70185 (E) Page 78 Revision 3.0 DATA PROGRAMMING Assignment of Telephone Numbers 6.1.2 When FCH is Mounted in a High Density Slot If the FCH is to be mounted in the High Density Slot, the connection trunk data should be assigned as shown in the figures below. Figure 5-24 shows an example where these cards are mounted in Slots 11 and 12. Figure 5-24 Mounting FCH and DTI Cards in High-Density Slots 00 02 04 05 06 07 08 09 10 13 14 15 16 17 18 19 20 21 22 23 12 13 1415 0001 02 0001 02 0404...
Page 94
ND-70185 (E) CHAPTER 5 Page 79 Revision 3.0 DATA PROGRAMMING Assignment of Telephone Numbers When the DTI cards is mounted in a double density slot, the C_LEN data for the FCH and DTI cards are as follows. Figure 5-25 How to Assign C_LEN Data (Type 2) 0002 04 05 06 0708 09 1011 12 1314 1516 1718 1920 2122 23 04 02 00 06 1005 07 11 12 131415 161718 0001 02 04 06 08 10 03 05 07 09 11 1213 14 15 1617 18 19 20 21 22 23 08 09 PIM Universal SlotsUniversal Slots PWR DPWR TSW/MUX TSW/MUX03 01 FCH DTI DTI...
Page 95
CHAPTER 5 ND-70185 (E) Page 80 Revision 3.0 DATA PROGRAMMING Assignment of Telephone Numbers Table 5-3 Data Programming Sheet for High Density Slot C_RT (1-1023)C_TK (1-4095)C_LENS Time Slot Allocation MG U G LV 10 (B-ch)1 000210 2 000211 3 000212 4 000213 5 000214 6 000215 7 000216 8 000217 9 000220 10 000221 11 000222 12 000223 13 000224 14 000225 15 000226 16 000227 17 000230 18 000231 19 000232 20 000233 21 000234 22 000235 23 000236 11 (D-ch)1 000237 2 000190 1112 19 23 22 21Dch (TK1) Bch (TK23) Bch...
Page 96
ND-70185 (E) CHAPTER 5 Page 81 Revision 3.0 DATA PROGRAMMING Assignment of FCH Related Data STEP 4: MBCT Unbusy the connection trunk data assigned in the previous step using MBCT (Make Busy of Connec- tion Trunk) command. This step is required for both B-channel and D-channel trunk. The MBCT command should look similar to the following. Figure 5-26 MBCT Command Display 7. Assignment of FCH Related Data STEP 1: For Fusion with FCH only: Assign FCH Number on an FCH (PA-FCHA) circuit card basis. The...
Page 97
CHAPTER 5 ND-70185 (E) Page 82 Revision 3.0 DATA PROGRAMMING Assignment of FCH Related Data Figure 5-29 shows a sample data assignment when FCH cards are located in the PIM 0 slot 4 and PIM 2 slot 11. Figure 5-27 Assignment of FCH Number The AFCH command display should look similar to the following: Figure 5-28 AFCH Command Display (example) NECNEAX 2400 IMS FCHN=2 LENS: 000270FCHN=1 As an example, data assignment when FCH cards are accommodated in the following slots is shown here. PIM 0, slot 4 and...
Page 98
ND-70185 (E) CHAPTER 5 Page 83 Revision 3.0 DATA PROGRAMMING Assignment of FCH Related Data STEP 2: AFRT (Fusion with FCH only) Assign connection route numbers as shown below using the AFRT command. Figure 5-29 AFRT Sample Data Sheet The AFRT command display should look similar to Figure 5-30. Figure 5-30 AFRT Command Display FCHN = 1 CNT = 1 C_RT : 10 LN LN LN LN LN LN NCN1 2 C_RT=10 Node A Node BFCIC=1 FCHN=1 FCIC=1FCIC=2 FCIC=n FCIC=2 FCIC=n TRK 1 TRK 10TRK 3TRK 31 TRK 32 TRK 40 : ::...
Page 99
CHAPTER 5 ND-70185 (E) Page 84 Revision 3.0 DATA PROGRAMMING Assignment of FCH Related Data STEP 3: AFPCAssign FCH routing data using the AFPC command. A maximum of 8 connection routes and FCHN/ FPCN can be assigned on a node basis. FCHN is used for Fusion System with FCH. FPCN is used for Fusion System without FCH. The list box labeled FCH on the AFPC command determines the system type. Assign “0” for Fusion System without FCH and “1” for Fusion System with FCH. In this step, the explanation is...
Page 100
ND-70185 (E) CHAPTER 5 Page 85 Revision 3.0 DATA PROGRAMMING Assignment of FCH Related Data The table in Figure 5-33 shows a sample data sheet for Node A on a Fusion network with FCH. Assign the data for all nodes including the nodes which are not directly connected on the network. For example, in this figure Node C and Node D are not directly connected to the network. Figure 5-33 AFPC Sample Data Sheet FPC 2(to Node B) FCCH 1(with FCH) CNT C_RT FCHN 1 10 1 FPC 21(to Node...