Key Setting on Circuit Cards
SW4D1ON Transmission Signal A Logic: Negative
OFF×Transmission Signal A Logic: Positive
2ON Receiving Signal A Logic: Negative
OFF×Receiving Signal A Logic: Positive
3ON RMT Alarm Sending: Not to be sent out
OFF×RMT Alarm Sending: To be sent out
4ON×Simultaneous Seizure Supervision: Not to be 
controlled
OFFSimultaneous Seizure Supervision: To be con-
trolled
5ON Data Link Control: MOS
OFF×Data Link Control: BOS
6ON...

Page 52

ND-70185 (E) CHAPTER 4
Page 37
Revision 3.0
INSTALLATION
Key Setting on Circuit Cards
SW391ON
OFF×
2ON×
OFF
3ON×
OFF
4ON×
OFF
5ON×
OFF
6ON
OFF×
7ON×
OFF
8ON
OFF× Table 4-4 Switch Setting Patterns for the DTI Card (Continued)
SWITCH NAMESWITCH 
NUMBERSETTINGSTANDARD 
SETTINGMEANING
1
234
5
678
OFF
SW39-1 SW39-2 PAD CONTROL
ON ON Both directions 
OFF ON Receiving only
ON OFF Sending only
OFF OFF ARTD is fixed
SW39-3 SW39-4 DATA PAD
ON ON 64K
OFF ON 56K
ON OFF 48K
OFF OFF 64K INV.
SW39-5 SW39-6 T SIG...

Page 53

CHAPTER 4 ND-70185 (E)
Page 38
Revision 3.0
INSTALLATION
Key Setting on Circuit Cards
SW6C1ON×Fixed
2ON×Fixed
3ON×Fixed
4ON×Fixed
5ON×Fixed
6ON×Fixed
7ON×Fixed
8ON×Fixed
SW581ON Equalizer Setting
OFF
2ON
OFF
3ON
OFF
4ONPAD Pattern Selection
Note:When setting this key, refer to Digital
PAD Setting Table (Table 4-5). OFF×
5ON×
OFF
6ON×
OFF
7ON
Alarm Sending when this circuit card is in N-
OPE state. OFF×
8ON×
OFF Table 4-4 Switch Setting Patterns for the DTI Card (Continued)
SWITCH NAMESWITCH...

Page 54

ND-70185 (E) CHAPTER 4
Page 39
Revision 3.0
INSTALLATION
Key Setting on Circuit Cards
Note:
This switch setting is applicable for a system which adopts Associated Channel Interoffice Signalling
(ACIS).
2.4 Digital PAD Setting
The PA-24DTR card is equipped with a mask ROM in which the following typical PAD patterns have been
already written. PAD value is determined by selecting a desired PAD pattern, which can be done by key
setting of the SW 58 (elements 4, 5, 6) on the card, and programming of the PAD...

Page 55

CHAPTER 4 ND-70185 (E)
Page 40
Revision 3.0
INSTALLATION
Mounting Circuit Cards in PIM
3. Mounting Circuit Cards in PIM
3.1 Mounting HUB (PA-M96) in a PIM
Mount the HUB (PA-M96) card in an appropriate slot of a PIM as shown below. When the MAT is con-
nected via a HUB card, be sure to use a dedicated HUB for the Fusion link.
Note:HUB (PA-M96) can be mounted wherever in a PIM of any IMG stack. However, if your system is 1-IMG
type, mount the HUB in PIM0.
Figure 4-7   Mounting HUB Card in PIM 0...

Page 56

ND-70185 (E) CHAPTER 4
Page 41
Revision 3.0
INSTALLATION
Mounting Circuit Cards in PIM
3.2 Mounting FCH (PA-FCHA) and DTI (PA-24DTR) Cards
Mount the FCH (PA-FCHA) and the DTI (PA-24DTR) card in appropriate slots in a PIM. Mount the two
cards in adjacent slots since these cards must be connected on the front connectors. Figure 4-8 shows an
example with the FCH and DTI cards mounted in PIM 1.
Figure 4-8   Mounting FCH and DTI Cards
ATTENTIONContents
Static Sensitive
Handling
Precautions Required
This...

Page 57

CHAPTER 4 ND-70185 (E)
Page 42
Revision 3.0
INSTALLATION
Connecting Cables
4. Connecting Cables
4.1 Connecting DTI-FCH Front Cables
Connect the furnished front cable to the connectors on the DTI and FCH cards. Use DTI and CN2 connec-
tors on the FCH and DTI cards respectively. Since an FCH card is equipped with one Handler circuit, a
maximum of five FCH cards can be connected to a DTI card. (See Figure 4-10.) However, if a DCH card
is also cascaded, a maximum of three FCH cards can be added to the DTI...

Page 58

ND-70185 (E) CHAPTER 4
Page 43
Revision 3.0
INSTALLATION
Connecting Cables
Since a maximum of five Handler circuits can be used, five FCH cards can be cascaded. Figure 4-10 shows an 
example where three FCH cards are cascaded.
Figure 4-10   FCH Cascade Connections
ATTENTIONContents
Static Sensitive
Handling
Precautions Required
Since a maximum of five  Handler circuits can be used, five FCH cards can be cascaded.  This figure shows an example where three 
FCH cards are cascaded.  

222
DTI
CN2
FCH...

Page 59

CHAPTER 4 ND-70185 (E)
Page 44
Revision 3.0
INSTALLATION
Connecting Cables
4.2 Connecting 10 BASE-T Cables
Figure 4-11 shows sample cable connections, where HUB (PA-M96) cards are provided in a dual configu-
ration and the FCH (PA-FCHA) card is located in PIM 1 (1-IMG system/IMG0). When HUB cards are pro-
vided in a dual configuration, the two HUB cards must be connected on each front edge connector using a
10 BASE-T cross cable. However, when dual LANIs (LANI-A and LANI-B) are used for each CPU, the...

Page 60

ND-70185 (E) CHAPTER 4
Page 45
Revision 3.0
INSTALLATION
Connecting Cables
4.3 10 BASE-T Connection Procedure
The pattern for 10 BASE-T cable connections may vary, depending on the system configuration (such as
number of IMG stacks or the mounting location/number of the FCH/HUB cards, etc.). According to your
system configuration, connect necessary Ethernet cables:
4.3.1 Procedure for 1-IMG System
If your system is 1-IMG type, the 10 BASE-T connection should use either of the following cables:
1. Cable...