Page 41

CHAPTER 3 ND-70185 (E)
Page 26
Revision 3.0
SYSTEM CONFIGURATION
System Considerations
3.4.2 Central Office Incoming Call (Ring Down)
Each node can specify a terminating node for Ring Down calls using the system data. In this example,
Node A and Node D specify Node C and Node E as the terminating node respectively. The terminating
node is assigned using the ASYDL command (SYS 1,  Index 640). Note that self-FPC is assigned at the
terminating node.
Note 1:When assigning the data regarding the call...

Page 42

ND-70185 (E) CHAPTER 3
Page 27
Revision 3.0
SYSTEM CONFIGURATION
System Considerations
3.4.3 Day/Night Change
Day/Night information is transferred from an ATTCON/DESKCON to predetermined nodes.  In this example,
Node C specifies Node A and Node B as destination nodes by assigning FPCs 1 and 2 in Indexes 704-735. Node
A and Node B specifies Node C as a terminating node for Ring Down calls from PSTN by assigning FPC 3 in
Index 640. Node E specifies Node D as a destination.
Note 1:When assigning...

Page 43

CHAPTER 3 ND-70185 (E)
Page 28
Revision 3.0
This page is for your notes. 

Page 44

ND-70185 (E) CHAPTER 4Page 29
Revision 3.0
CHAPTER 4 INSTALLATION
This chapter covers the installation of the Fusion system. The following topics are covered: 
 How to set switches on the following circuit cards:
PA-M96 (HUB)
PA-FCHA (FCH)
PA-24DTR (DTI)
 How to mount the circuit cards
 How to run the 10 BASE-T cables
1. Anti-Static Caution
This manual provides Static Caution indicators on pages where work involving static-sensitive components is 
described. When performing work accompanied by this...

Page 45

CHAPTER 4 ND-70185 (E)
Page 30
Revision 3.0
INSTALLATION
Anti-Static Caution
Figure 4-2 shows the anti-static kit that is provided. Use the kit as shown below when handling static-sensitive
components such as circuit cards and cables.
Figure 4-2   How to Use the Anti-static Kit


PBX

 Connect the ground wire to the earth terminal of the frame.
Earth Terminal
Ground Wire
Conductive SheetWrist Strap
Ground Cable 

Page 46

ND-70185 (E) CHAPTER 4
Page 31
Revision 3.0
INSTALLATION
Anti-Static Caution
1.1 Circuit Cards Required
Depending on the system type, the following circuit cards are required to install the Fusion system:
 Fusion with FCH
HUB (PA-M96)
FCH (PA-FCHA)
DTI (PA-24DTR)
 Fusion without FCH
DTI (PA-24DTR)
HUB (PA-M96)
Before starting installation, make sure that all necessary cards are at your site.
Figure 4-3   Circuit Cards for Fusion
4C026A12
34
OFF
12
34
567
8
OFF
12
34
5
67
8
OFF
12
34
567
8
OFF
1
234...

Page 47

CHAPTER 4 ND-70185 (E)
Page 32
Revision 3.0
INSTALLATION
Key Setting on Circuit Cards
2. Key Setting on Circuit Cards
2.1 PA-M96 (HUB)
Set the SEL switch on the HUB (PA-M96) card(s), after referring to Figure 4-4 and Ta b l e  4 - 1.
Figure 4-4   Switch Setting on HUB (PA-M96) Card
Table 4-1 SENSE Switch Setting
SWITCH NAME SETTINGSTANDARD 
SETTINGDESCRIPTION
SENSE0 Polarity indication on the STn lamps for TPn-Xports.
1 Not used.
2×TPn-X ports operate as a repeater HUB. (Standard setting)...

Page 48

ND-70185 (E) CHAPTER 4
Page 33
Revision 3.0
INSTALLATION
Key Setting on Circuit Cards
2.2 PA-FCHA (FCH)
Set the switches on the FCH (PA-FCHA) card(s) as shown below. This card has DIP switches, whose key
settings determine the time slots of the Fusion link. In Figure 4-5, CH3 is designated as the D/I channel in
an example.
Figure 4-5   Switch Setting on FCH (PA-FCHA) Card
4C026AE

12
34
OFF
12
34
567
8
OFF
12
34
5
67
8
OFF
12
34
567
8
OFF
1
234
567
8
OFF

12
34
OFF
12
34
567
8
OFF
12
34
5
67
8
OFF
12...

Page 49

CHAPTER 4 ND-70185 (E)
Page 34
Revision 3.0
INSTALLATION
Key Setting on Circuit Cards
Note 1:
64Kbps is used for T1 or E1 interface.
56Kbps is used for T1 interface with bit stealing.
48Kbps is used for T1 interface with both bit stealing and Zero Code Suppression (or Bit 7 Stuffing).
Note 2:When n is bigger than 1, Time Slot Sequence Integrity (TSSI) must be guaranteed at the network side.
Note 3:The following is an example key setting when n = 2.
SW11-1 = ON
SW11-2 = ON
Table 4-2 MODE Switch Setting...

Page 50

ND-70185 (E) CHAPTER 4
Page 35
Revision 3.0
INSTALLATION
Key Setting on Circuit Cards
2.3 PA-24DTR (DTI)
There are two types of the PA-24DTR (DTI) card as shown below. Refer to Figure 4-6 and Table 4-4 to set
each switch to the proper positions.
Figure 4-6   Switch Locations on DTI (PA-24DTR) Card
Table 4-4 Switch Setting Patterns for the DTI Card
SWITCH NAMESWITCH 
NUMBERSETTINGSTANDARD 
SETTINGMEANING
MB
UP Circuit card make busy
DOWN×Circuit card make busy cancel
SW13B0ON Internal Loopback: Set...