Page 41
CHAPTER 3 ND-70185 (E) Page 26 Revision 3.0 SYSTEM CONFIGURATION System Considerations 3.4.2 Central Office Incoming Call (Ring Down) Each node can specify a terminating node for Ring Down calls using the system data. In this example, Node A and Node D specify Node C and Node E as the terminating node respectively. The terminating node is assigned using the ASYDL command (SYS 1, Index 640). Note that self-FPC is assigned at the terminating node. Note 1:When assigning the data regarding the call...
Page 42
ND-70185 (E) CHAPTER 3 Page 27 Revision 3.0 SYSTEM CONFIGURATION System Considerations 3.4.3 Day/Night Change Day/Night information is transferred from an ATTCON/DESKCON to predetermined nodes. In this example, Node C specifies Node A and Node B as destination nodes by assigning FPCs 1 and 2 in Indexes 704-735. Node A and Node B specifies Node C as a terminating node for Ring Down calls from PSTN by assigning FPC 3 in Index 640. Node E specifies Node D as a destination. Note 1:When assigning...
Page 44
ND-70185 (E) CHAPTER 4Page 29 Revision 3.0 CHAPTER 4 INSTALLATION This chapter covers the installation of the Fusion system. The following topics are covered: How to set switches on the following circuit cards: PA-M96 (HUB) PA-FCHA (FCH) PA-24DTR (DTI) How to mount the circuit cards How to run the 10 BASE-T cables 1. Anti-Static Caution This manual provides Static Caution indicators on pages where work involving static-sensitive components is described. When performing work accompanied by this...
Page 45
CHAPTER 4 ND-70185 (E) Page 30 Revision 3.0 INSTALLATION Anti-Static Caution Figure 4-2 shows the anti-static kit that is provided. Use the kit as shown below when handling static-sensitive components such as circuit cards and cables. Figure 4-2 How to Use the Anti-static Kit PBX Connect the ground wire to the earth terminal of the frame. Earth Terminal Ground Wire Conductive SheetWrist Strap Ground Cable
Page 46
ND-70185 (E) CHAPTER 4 Page 31 Revision 3.0 INSTALLATION Anti-Static Caution 1.1 Circuit Cards Required Depending on the system type, the following circuit cards are required to install the Fusion system: Fusion with FCH HUB (PA-M96) FCH (PA-FCHA) DTI (PA-24DTR) Fusion without FCH DTI (PA-24DTR) HUB (PA-M96) Before starting installation, make sure that all necessary cards are at your site. Figure 4-3 Circuit Cards for Fusion 4C026A12 34 OFF 12 34 567 8 OFF 12 34 5 67 8 OFF 12 34 567 8 OFF 1 234...
Page 47
CHAPTER 4 ND-70185 (E) Page 32 Revision 3.0 INSTALLATION Key Setting on Circuit Cards 2. Key Setting on Circuit Cards 2.1 PA-M96 (HUB) Set the SEL switch on the HUB (PA-M96) card(s), after referring to Figure 4-4 and Ta b l e 4 - 1. Figure 4-4 Switch Setting on HUB (PA-M96) Card Table 4-1 SENSE Switch Setting SWITCH NAME SETTINGSTANDARD SETTINGDESCRIPTION SENSE0 Polarity indication on the STn lamps for TPn-Xports. 1 Not used. 2×TPn-X ports operate as a repeater HUB. (Standard setting)...
Page 48
ND-70185 (E) CHAPTER 4 Page 33 Revision 3.0 INSTALLATION Key Setting on Circuit Cards 2.2 PA-FCHA (FCH) Set the switches on the FCH (PA-FCHA) card(s) as shown below. This card has DIP switches, whose key settings determine the time slots of the Fusion link. In Figure 4-5, CH3 is designated as the D/I channel in an example. Figure 4-5 Switch Setting on FCH (PA-FCHA) Card 4C026AE 12 34 OFF 12 34 567 8 OFF 12 34 5 67 8 OFF 12 34 567 8 OFF 1 234 567 8 OFF 12 34 OFF 12 34 567 8 OFF 12 34 5 67 8 OFF 12...
Page 49
CHAPTER 4 ND-70185 (E) Page 34 Revision 3.0 INSTALLATION Key Setting on Circuit Cards Note 1: 64Kbps is used for T1 or E1 interface. 56Kbps is used for T1 interface with bit stealing. 48Kbps is used for T1 interface with both bit stealing and Zero Code Suppression (or Bit 7 Stuffing). Note 2:When n is bigger than 1, Time Slot Sequence Integrity (TSSI) must be guaranteed at the network side. Note 3:The following is an example key setting when n = 2. SW11-1 = ON SW11-2 = ON Table 4-2 MODE Switch Setting...
Page 50
ND-70185 (E) CHAPTER 4 Page 35 Revision 3.0 INSTALLATION Key Setting on Circuit Cards 2.3 PA-24DTR (DTI) There are two types of the PA-24DTR (DTI) card as shown below. Refer to Figure 4-6 and Table 4-4 to set each switch to the proper positions. Figure 4-6 Switch Locations on DTI (PA-24DTR) Card Table 4-4 Switch Setting Patterns for the DTI Card SWITCH NAMESWITCH NUMBERSETTINGSTANDARD SETTINGMEANING MB UP Circuit card make busy DOWN×Circuit card make busy cancel SW13B0ON Internal Loopback: Set...