Page 111

CHAPTER 5 ND-70185 (E)
Page 96
Revision 3.0
DATA PROGRAMMING
Assignment of FCH Related Data
STEP 8: AFPC
Assign the FCCS routing data.
FPC: 1 (FPC of the adjacent node)FCCH: 1 (with FCCH)
CRT: 10 FCHN: 2
STEP 9: ACAN
Assign the CIC number to the connection trunk.
FPC: 1 FCIC: 1-664 CLENS: LEN of the connection trunk
STEP 10: AFCD
Assign NAILED DOWN CONNECTION for the connection link established between FCCH and
SDT.
LENS-A: LEN of SDT EAD-A: 07 (pad off)
LENS-B: LEN of FCCH EAD-B: 07 (pad off) 

Page 112

ND-70185 (E) CHAPTER 5
Page 97
Revision 3.0
DATA PROGRAMMING
Assignment of FCH Related Data
7.3 FCCS Link via Internet/Intranet
The system can exchange FCCS data via the Internet/Intranet. As shown below, an FCCS Link can be es-
tablished by using the following features:
 External Router
 Fusion over IP
7.3.1 External Router
This feature allows the system to exchange the FCCS data via the Internet/Ethernet. For this feature, an
FCCS link is connected to an external router.
Figure 5-39   External Router...

Page 113

CHAPTER 5 ND-70185 (E)
Page 98
Revision 3.0
DATA PROGRAMMING
Assignment of FCH Related Data
STEP 1: ACRD
Assign Route Class Data of Speech Route, FCH, FGH routes, respectively. A sample data assignment
is shown below.
See 6.1 Assignment of Connection Route/Trunk Data for more detailed information.
Figure 5-41   Connection Route Class Data Sample
FGHFCCH Speech
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16FGHTF
TCL
RLP
SMDR
LSG
PA D
TRKS
TC/EC
FINT
FPEG
TC
MTC
STSEQ
MMN
LKIND3
4
2
0
12
0(1)
0
0
0
0
2 03
4
2
0...

Page 114

ND-70185 (E) CHAPTER 5
Page 99
Revision 3.0
DATA PROGRAMMING
Assignment of FCH Related Data
STEP 2: ACTK
Assign the connection trunk data of DTI, FCH, and FGH cards, using the ACTK command. When
assigning FCH, FGH trunk data, eight trunks must be set. A sample data assignment of FCH, FGH
card is as follows.
Figure 5-42   Sample Data Assignment (ACTK)
PWR PWR
FCH(RT14)
FGH(RT15)C_RT
C_TKC_LENS
14
14
14
14
14
14 14 14 (1-1023)
(1-4095)MG U G L
00-07 0-3 00-23 0-7
0
1
2
3
4
5
6
7 1
2
3
4
5
6
7
803 000
03...

Page 115

CHAPTER 5 ND-70185 (E)
Page 100
Revision 3.0
DATA PROGRAMMING
Assignment of FCH Related Data
STEP 3: AFCH
Assign FCH number on an FCH circuit card basis. In the following example, FCHN=1 is assigned
for the FCH circuit card. For the FGH card, FCHN assignment is not necessary.
Figure 5-43   Assignment of FCHN (Example)
STEP 4: AGIP
Assign IP addresses of FGH card and its connected router.
FCHEN (FCH Equipment Number): Assign LV0 data of FGH LENs.
FGH_IP (FGH IP Address): Assign IP address of the FGH...

Page 116

ND-70185 (E) CHAPTER 5
Page 101
Revision 3.0
DATA PROGRAMMING
Assignment of FCH Related Data
STEP 5: AFPC
Assign internal LAN routing data.
FPC (Fusion Point Code): Assign FPC number (1-253) of the Destination Node.
FCCH: Assign 1.
C_RT (Connection Router): 1-1023
FCHN/FPCN (FCH/FPC Number): Assign the FCH Number, specified in STEP 3.
USE_GATE: Assign 1 (=Gateway function is used).
P_ROUTE (Priority Route): 0/1 = FCH/FGH
Example data assignment is shown in Figure 5-44 and Figure 5-45:
Figure 5-44...

Page 117

CHAPTER 5 ND-70185 (E)
Page 102
Revision 3.0
DATA PROGRAMMING
Assignment of FCH Related Data
STEP 6: AETH
Assign the external router routing data.
FPC (Fusion Point Code): Assign FPC number (1-253) of the Destination Node.
USE_GATE: Assign 1 (=use Gateway).
FCHN (FCH Number): Assign the FCH Number, specified in STEP 3.
C_RT (Connection Route): 1-1023
DST_IP (Destination IP Address): Assign FGH IP address of the Destination Node.
NEXT_IP (Next IP Address): Assign FGH IP address of the Next Node (Node to...

Page 118

ND-70185 (E) CHAPTER 5
Page 103
Revision 3.0
DATA PROGRAMMING
Assignment of FCH Related Data
STEP 7: ACAN
Assign the Fusion Connection Index Code (FCIC) for the Next Node.
FPC (Fusion Point Code): Assign FPC number of the Next Node (Node to be passed to).
FCIC (Fusion Connection Index Code): Assign Fusion CIC of the Next Node (Node to be passed to).
C_LENS (Connection_LENS): Assign DTI LENS data (Bch data), specified in STEP 2.
Figure 5-48   Sample Data Assignment (ACAN)
STEP 8: MBCT
Unbusy the...

Page 119

CHAPTER 5 ND-70185 (E)
Page 104
Revision 3.0
DATA PROGRAMMING
Assignment of FCH Related Data
7.3.2 FCCS Networking over IP
This feature allows the system to exchange both speech and FCCS signaling over Internet/Intranet. To
establish/release a call, Q-sig is used between the system and the router. H.323 is used as a protocol be-
tween routers.
Figure 5-49   FCCS Networking over IP - Overview
 
Figure 5-50   Hardware Connections for FCCS Networking over IP
POWERInternet/
Intranet
Speech
Signaling
PBXPBX...

Page 120

ND-70185 (E) CHAPTER 5
Page 105
Revision 3.0
DATA PROGRAMMING
Assignment of FCH Related Data
STEP 1: ACRD
Assign Route Class Data of Speech Route, FCH, FGH routes, respectively. A sample data assignment
is shown below.
Figure 5-51   Sample Data Assignment (ACRD)
STEP 2: ACTK
Assign the connection trunk data of DTI, FCH, and FGH cards, using the ACTK command. When
assigning FCH, FGH trunk data, eight trunks must be set. A sample data assignment of FCH, FGH
card is as follows.
Figure 5-52   Sample Data...