Page 791
NEAX2400 IMX Feature Programming Manual ND-70184 (E), Issue 3 Page 747 Variable Timing Parameters V-1 V-1 Variable Timing Parameters General Description The Variable Timing Parameters feature gives the PBX the versatility to change timing parameters, using the MAINTENANCE ADMINISTRATION TERMINAL (MAT) [M-18]. All timing parameters for a specific timing sequence are set initially within the generic program. These timing parameters can be changed to accommodate user requirements. Operating Procedure No...
Page 792
NEAX2400 IMX Feature Programming Manual Page 748ND-70184 (E), Issue 3 V-1 Variable Timing Parameters Interactions 1. To calculate VARIABLE TIMING PARAMETERS, multiply the Timer Class by the Miscellaneous Timer Class, TC x MTC = VARIABLE TIMING PARAMETER. TC is a set value. MTC is any value from 1-15, assigned in hexadecimal. For the PERIODIC TIME INDICATION TONE Timer, a TC of 3 equaling 2 seconds is not available, but a TC of 4 equaling 30 seconds is available. Timer Index: TC values for Indexes 136,...
Page 793
NEAX2400 IMX Feature Programming Manual ND-70184 (E), Issue 3 Page 749 Variable Timing Parameters V-1 Interactions (cont’d) TC values for Indexes 142, 143, 144 TC 0 = - 1 = - 2 = - 3 = 2 seconds 4 = 30 seconds 7 = 8 seconds. TC values for Indexes 135 TC 0 = - 1 = 64 msec. TC values for Indexes 149 TC 0 = - 1 = - 2 = - 3 = 2 seconds 4 = 30 seconds. TC values for Indexes 145 TC 0 = - 1 = 2 seconds. Programming ASYD - System Data 1. All VARIABLE TIMING PARAMETERS are located between Indexes 128 and...
Page 794
NEAX2400 IMX Feature Programming Manual Page 750ND-70184 (E), Issue 3 V-2 Voice Call V-2 Voice Call General Description This feature enables a single line telephone to make a VOICE CALL [V-2] when the called party is a Dterm set. This path exists from the calling party to the called partys built-in speaker. If the called partys MIC is on, the called party can converse hands-free. Operating Procedure From a single line station to a Dterm: 1. Dial the telephone number of the desired Dterm station and...
Page 795
NEAX2400 IMX Feature Programming Manual ND-70184 (E), Issue 3 Page 751 Voice Call V-2 Programming (cont’d) For a Dterm: STEP 1:AKYD - Assign the station according to the following parameters: TN: 1 STN: Station Number TP: Type of D term 0/1: RING: 0: No Ringing 1: Ringing All Lines 2: Ringing on Prime Line Only 3: Flexible Ring Assignment, enables RG parameter. KYN: Key Number (1-40) KYI: Service Index 0: Key Not Used 1: Feature Key 2: Multi-line Key KD: Not assigned for Feature Key FKY:...
Page 796
NEAX2400 IMX Feature Programming Manual Page 752ND-70184 (E), Issue 3 V-2D Voice Call - Dterm V-2D Voice Call - Dterm General Description This feature provides a voice path between two Dterm sets. This path exits from the calling party to the called party’s built-in speaker. If the called party’s MIC key is on, the called party can converse hands-free. Operating Procedure From one Dterm to another Dterm: 1. The originating Dterm user dials the desired telephone number and receives a ringback tone. 2....
Page 797
NEAX2400 IMX Feature Programming Manual ND-70184 (E), Issue 3 Page 753 Voice Call - DtermV-2D Interactions A Voice Call cannot be sent to a single-line station. Programming Operating with the feature key: STEP 1:AKYD - Assign the station according to the following parameters: TN: 1 STN: Station Number TP: Type of D term 0/1: RING: 0: No Ringing 1: Ringing All Lines 2: Ringing on Prime Line Only 3: Flexible Ring Assignment, enables RG parameter. KYN: Key Number (1-40) KYI: Service Index 0: Key...
Page 798
NEAX2400 IMX Feature Programming Manual Page 754ND-70184 (E), Issue 3 V-3D Volume Control - Dterm V-3D Volume Control - Dterm General Description This feature is used for controlling the volume of a Dterm set’s built-in speaker and receiver. Operating Procedure 1. The Dterm set is equipped with a sliding volume control knob located in the front, beneath the dial pad. Volume can be increased by moving the control to the right, and decreased by moving it to the left. 2. The ringing volume is controlled by...
Page 799
NEAX2400 IMX Feature Programming Manual ND-70184 (E), Issue 3 Page 755 WATS Access W-1 W-1 WATS Access General Description This feature permits any user direct-dial access to outgoing WATS lines. Operating Procedure 1. Lift the handset; receive dial tone. 2. Dial the WATS ACCESS code. 3. Receive second dial tone. 4. Dial the desired number. Service Conditions Access to WATS lines may be denied to individual stations via CLASS OF SERVICE-INDIVIDUAL [C-15]. Interactions 1. WATS ACCESS will operate in...
Page 800
NEAX2400 IMX Feature Programming Manual Page 756ND-70184 (E), Issue 3 W-1 WATS Access Programming (cont’d) STEP 5:ASPA - Assign the access code as assigned in ANPD above. Type of Service, SRV = OGC (Outgoing Call) Outgoing Trunk. Assign the route number associated with this access code. STEP 6:ARSC - The Route Restriction Class must be constructed to allow the station access to the involved routes.