Page 811

NEAX2400 IMX Feature Programming Manual
ND-70184 (E), Issue 3
Page 767
Attendant-Controlled Conference - CCIS A-46
Interactions (cont’d)
2. NEC provides a PA-16LCBE circuit card that provides momentary-open for all 16 circuits. This is
required to provide a release signal when line circuits are connected to external equipment such as
conference and page units. This keeps reorder tone from being sent to the Conference Unit. 
3. The last port of a PA-16LCBJ/PA-16LCBL provides battery reversal upon release....

Page 812

NEAX2400 IMX Feature Programming Manual
Page 768ND-70184 (E), Issue 3
A-71 Automatic Recall - CCIS
A-71 Automatic Recall - CCIS
General Description
This service feature works as a time reminder. When an attendant-handled call through CCIS remains on hold,
camped-on or ringing unanswered for a fixed interval, the attendant is automatically alerted. 
Operating Procedure
No manual operation is required.
Service Conditions
1. AUTOMATIC RECALL timing is preset in System Data at 30 seconds. See the VARIABLE...

Page 813

NEAX2400 IMX Feature Programming Manual
ND-70184 (E), Issue 3
Page 769
Automatic Recall - CCIS A-71
Interactions (cont’d)
5. The station will continue to ring, even as the call recalls to the Attendant Console. When conference is
allowed and a conference card is programmed and installed, if the station should answer at the same time
the Attendant answers the recalling call, a three-way conversation will then take place. The Attendant can
press the SRC, DEST, or TALK keys to achieve the desired...

Page 814

NEAX2400 IMX Feature Programming Manual
Page 770ND-70184 (E), Issue 3
A-87 Automatic Number Identification (ANI) - CCIS
A-87 Automatic Number Identification (ANI) - CCIS
General Description
This service is an enhancement from AUTOMATIC NUMBER IDENTIFICATION (ANI), which can be executed
only within the self office. This enhanced service allows ANI at the primary office, with respect to an
EMERGENCY CALL terminated from the secondary office via the CCIS line.
Operating Procedure
No manual operation is...

Page 815

NEAX2400 IMX Feature Programming Manual
ND-70184 (E), Issue 3
Page 771
Automatic Number Identification (ANI) - CCIS A-87
Service Conditions (cont’d)
 If OG call is from an ATTCON and Individual ATT Access Code is assigned, and also ANI
data is assigned:
KP - 0
 - N**-****- ST
 If OG call is from an ATTCON and Individual ATT Access Code is unassigned, and ANI data
is assigned:
KP - 0
 -  N**-****- ST
 If OG call is from an ATTCON and ANI data is unassigned:
KP - 1
 - ST
b.) Outgoing call from...

Page 816

NEAX2400 IMX Feature Programming Manual
Page 772ND-70184 (E), Issue 3
A-87 Automatic Number Identification (ANI) - CCIS
Service Conditions (cont’d)
Station number: 2xxx, 3xxx
The COC digits are 822 or 823; then assign ANI information. 
Example 2:
 
Office number: 82, 826 
Station number: 34xxx, 4xxx 
The COC digits are 823 or 826; then assign ANI information. 
10. After digits have been sent out, DDD seizure tone is not sent. 
11. Other interactions are the same as those of outgoing call by MF...

Page 817

NEAX2400 IMX Feature Programming Manual
ND-70184 (E), Issue 3
Page 773
ANI-CCIS (16 Digit) A-126
A-126 ANI-CCIS (16 Digit)
General Description
This feature allows an office receiving ANI information from Central Office through an analog trunk (Caller ID or
MF) to extend to another office through CCIS when the tandem connection is established.
Operating Procedure
No manual operation is required.
Service Conditions
1. The maximum digits of ANI information sent to another office through CCIS are 16.
2. When...

Page 818

NEAX2400 IMX Feature Programming Manual
Page 774ND-70184 (E), Issue 3
A-126 ANI-CCIS (16 Digit)
Programming (cont’d)
System Data 1, Index 290, Bit 5. Expanded SMDR Output for SMDR B Apparatus. 0/1 = Out/In
Service.
System Data 1, Index 292, Bit 5. Expanded SMDR Output for SMDR C Apparatus. 0/1 = Out/In
Service.
System Data 1, Index 294, Bit 5. Expanded SMDR Output for SMDR D Apparatus. 0/1 = Out/In
Service.
System Data 1, Index 296, Bit 0. Output of Calling Number (ANI Information). 0/1 = Out/In...

Page 819

NEAX2400 IMX Feature Programming Manual
ND-70184 (E), Issue 3
Page 775
Busy Verification - CCIS B-9
B-9 Busy Verification - CCIS
General Description
This service feature allows Inter-Office Attendant BUSY VERIFICATION when the Attendant and the called party
respectively belong to a different PBX in the CCIS network.
Operating Procedure
1. Station (a) and (b) are in connection on a station-to-station call.
2. The Attendant in Node A presses the loop key; the loop lamp and DEST lamp on the Attendant...

Page 820

NEAX2400 IMX Feature Programming Manual
Page 776ND-70184 (E), Issue 3
B-9 Busy Verification - CCIS
Service Conditions (cont’d)
4. BUSY VERIFICATION cannot be established to a BUSY station when the station is: 
a.) Dialing
b.) Listening to a tone
c.) Being rung
d.) Protected by DATA LINE SECURITY [D-12] [D-66]
e.) Being connected to an BUSY VERIFICATION Loop
f.) Activating a conflicting feature, such as:
ATTENDANT CAMP-ON WITH TONE INDICATION [A-1][A-45] 
BOSS-SECRETARY OVERRIDE-D
term[B-5D] 
CALL HOLD...