PA - 1 6 E L C J
Electric Line Current
7. Switch Setting Sheet
MODULE SLOT No. SWITCH NAME SWITCH SHAPE REMARKS
PIMSW00
(MB)
SW01
ON
12345678ON 

Page 272

ND-70182 (E) CHAPTER 3Page 257
Revision 4.0
PA-16ELCJ-B
Electronic Line Circuit
PA-16ELCJ-B
Electronic Line Circuit
1. General Function
The PA-16ELCJ-B (ELC) circuit card provides an interface between D
term and IMX. Depending upon the
switch settings, this card works in the following two modes.
 16 ELC mode: A maximum of 16 sets of D
terms can be conn ected to this card. (voice communications
only)
 8 DLC mode: A maximum of 8 sets of D
terms can be connected to this card. (simultaneous voice and
data...

Page 273

CHAPTER 3 ND-70182 (E)
Page 258
Revision 4.0
PA - 1 6 E L C J - B
Electronic Line Circuit
2. Mounting Location/Condition
The PA-16ELCJ-B (ELC) card can be mounted in any universal slots as shown below.
3. Face Layout of Lamps, Switches, and Connectors
The face layout of lamps, switches, and connectors on this circuit card is shown in Figure 3-59.
Figure 3-59   Face Layout of PA-16ELCJ-B (ELC) Card
PIMMounting Module
00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23
PALM SW00 (MB)...

Page 274

ND-70182 (E) CHAPTER 3
Page 259
Revision 4.0
PA-16ELCJ-B
Electronic Line Circuit
4. Lamp Indications
The contents of lamp indications on this circuit card are shown in the table below.
Note:When the PALM lamp lights red, observe the following instructions. 
i) Identify the location where any in-house wires have a short circuit as to all lines which belong to the
PA-16ELCJ-B card whose PALM is on. 
ii) Repair the short-circuited wires of the associated D
term.
iii) Disconnect the D
term from the jack,...

Page 275

CHAPTER 3 ND-70182 (E)
Page 260
Revision 4.0
PA - 1 6 E L C J - B
Electronic Line Circuit
5. Switch Settings
Switches on the PA-16ELCJ-B card have the following meanings. 
Note:When using firmware SP-3419, set SW10-1=OFF, SW10-2=ON.
SWITCH FUNCTION SWITCH SETTING MEANING
SW00 (MB)Circuit Card Make-
busy keyCircuit Card Make-busy Cancel.
Circuit Card Make-busy.
SW10
1-2LP-PM
Interface mode 
setting/Group 
No. setting
NoteIn case of this circuit card is used from No. 0 to 
25 group.
Expanded Multiple Line...

Page 276

ND-70182 (E) CHAPTER 3
Page 261
Revision 4.0
PA-16ELCJ-B
Electronic Line Circuit
SW10-3: OFF, SW10-4: OFF SW10-3: OFF, SW10-4: ON
SW10-5: OFF16 set of D
terms per card.
Voice Communication only.8 set of Dterms per card.
Data Adapter is used.
SW10-5: ON16 set of D
terms per card.
Analog Port Adapter is used (Either D
term or 
Analog terminal can be used at the same time).8 set of D
terms per card.
Analog Port Adapter is used (Both D
term and 
Analog terminal can be used at the same time). 

Page 277

CHAPTER 3 ND-70182 (E)
Page 262
Revision 4.0
PA - 1 6 E L C J - B
Electronic Line Circuit
6. External Interface
Depending upon the applied mode (16ELC/8 DLC mode), external interface leads appear on the LT
connectors as follows.
16ELC mode
Figure 3-60   LT Connector Lead Accommodation (16ELC Mode) (1/2)
PIMMounting Module
26272829303132333435363738394041
1234567891011121314151642434445464748
1718192021222349502425
232221201918171615141312111009080706050403020100
LT6 LT7 LT8 LT9 LT10 LT11LT0 LT1 LT2 LT3...

Page 278

ND-70182 (E) CHAPTER 3
Page 263
Revision 4.0
PA-16ELCJ-B
Electronic Line Circuit
Figure 3-60   LT Connector Lead Accommodation (16ELC Mode) (2/2)
PIMMounting Module
26272829303132333435363738394041
1234567891011121314151642434445464748
1718192021222349502425
232221201918171615141312111009080706050403020100
LT6 LT7 LT8 LT9 LT10 LT11LT0 LT1 LT2 LT3 LT4 LT5
23 19 15
22 18 14
21 17 13
20 16 1223 19 15
22 18 14
21 17 13
20 16 12 11 09 07 05 03 01
10 08 06 04 02 00 11 09 07 05 03 01
10 08 06 04 02 00
Highway...

Page 279

CHAPTER 3 ND-70182 (E)
Page 264
Revision 4.0
PA - 1 6 E L C J - B
Electronic Line Circuit
8DLC mode 
Figure 3-61   LT Connector Lead Accommodation (8DLC Mode)
PIMMounting Module
26272829303132333435363738394041
1234567891011121314151642434445464748
1718192021222349502425
232221201918171615141312111009080706050403020100
LT6 LT7 LT8 LT9 LT10 LT11LT0 LT1 LT2 LT3 LT4 LT5
23 19 15
22 18 14
21 17 13
20 16 1223 19 15
22 18 14
21 17 13
20 16 12 11 09 07 05 03 01
10 08 06 04 02 00 11 09 07 05 03 01
10 08 06 04...

Page 280

ND-70182 (E) CHAPTER 3
Page 265
Revision 4.0
PA-16ELCJ-B
7. Switch Setting Sheet
MODULE SLOT No. SWITCH NAME SWITCH SHAPE REMARKS
PIMSW00
(MB)
SW10
SW11
ON
12345678ON
12345678ON 