CHAPTER 3 ND-70182 (E)
Page 276
Revision 4.0
PA-24LCBV
Line Circuit
8. Connecting Route Diagram
Connecting Route Diagram for the PA-24LCBV(LC) is as follows:
Note:A and B leads for Channels #0 - #7 appear from the LC Connector equipped on the front edge of the card.
Figure 3-66   Connecting Route Diagram for the PA-24LCBV (LC)
MDF
L1 
 
L2
L1 
 
L2
L1 
 
L2
L1 
 
L2
Jack Jack JackJackAnalog 
Terminal
Analog 
Terminal
Analog 
Terminal
Analog 
Terminal
A7 
 
B7 A0 
 
B0 A23 
 
B23A8 
 
B8
PBXLT Connector...

Page 292

ND-70182 (E) CHAPTER 3
Page 277
Revision 4.0
PA-24LCBV
Line Circuit
9. LC Cable Connection
Figure 3-67   Outer View of LC Cable
Earth Cable 3m 

Page 293

CHAPTER 3 ND-70182 (E)
Page 278
Revision 4.0
PA-24LCBV
Line Circuit
Figure 3-68   Cable Running of LC Cable (Example)
FRONT
REAR
LC Cable
LC Cable
LC Cable
LT  C a b l e
PA-24LCBV
Earth Plate
Earth Cable 

Page 294

ND-70182 (E) CHAPTER 3
Page 279
Revision 4.0
PA-FCHA
Fusion Call Control Handler
PA-FCHA
Fusion Call Control Handler
1. General Function
This circuit card is a protocol converter to carry the fusion-link-data from/to the other node. The Fusion-
Link-Data is received/transferred from/to the CPR via HUB (PA-M96) across the TCP/IP interface. Once
the FCH has received the fusion-link-data from the CPR, the HDLC CONT part of the FCH converts it to
the High Level Data Link Controller (HDLC) format, then drops...

Page 295

CHAPTER 3 ND-70182 (E)
Page 280
Revision 4.0
PA-FCHA
Fusion Call Control Handler
2. Mounting Location/ Condition
The FCH can be mounted in a universal slot of the PIM.
3. Face Layout of Lamps, Switches, and Connectors
The face layout of lamps, switches, and connectors is shown below.
Figure 3-70   Face Layout of PA-FCHA (FCH) Card 00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23
Mounting ModulePIM
PIM
Universal SlotsUniversal Slots
MB
OPE
EST3
EST2
EST1
EST0
PWALMLYR
LB
LOAD
MNT...

Page 296

ND-70182 (E) CHAPTER 3
Page 281
Revision 4.0
PA-FCHA
Fusion Call Control Handler
4. Lamp Indications
Lamp indications for this circuit card are shown in the table below.
5. Switch setting
Standard settings for switches on this circuit card are shown in the table below.
LAMP NAME COLOR STATE
OPE Green Remains lit while this circuit card is operating.
LY RGreen Remains lit while the Fusion link is established.
Flash Flashes when the Fusion link test result is fair. (60IPM)
OFF Remains off when either the...

Page 297

CHAPTER 3 ND-70182 (E)
Page 282
Revision 4.0
PA-FCHA
Fusion Call Control Handler
Note:
The following operations are required prior to extracting the card.
(1.)  Turn on the MNT3 switch.
(2.)  Flip the MB switch.
When the D/I DTI (1.5M) is connected with the card front cable.
Note:T203 timer designates the maximum idle time which does not transmit any data frames. As a basic rule, the
shorter T203 timer value, the earlier link failure detection will be obtained.
MNT0OFF×Not used.
1OFF×Not used.
2OFF×Not...

Page 298

ND-70182 (E) CHAPTER 3
Page 283
Revision 4.0
PA-FCHA
Fusion Call Control Handler
SWITCH 
NAMESWITCH 
NOSETTINGSTANDARD 
SETTINGDESCRIPTION
SW11
Note 11ON
This SW designates the D/I channel of the 
Fusion-Link-Data.   (The number of D/I channels = n)
Set the corresponding SW(s) to “ON” for D/I, “OFF” for
denial. OFF
2ON
OFF
3ON
OFF
4ON
OFF
5ON
OFF
6ON
OFF
7ON
OFF
8ON
OFF
SW11 D/I channel of T1
SW11-1 CH 0
SW11-2 CH 1
SW11-3 CH2
SW11-4 CH 3
SW11-5 CH 4
SW11-6 CH 5
SW11-7 CH 6
SW11-8 CH 7 

Page 299

CHAPTER 3 ND-70182 (E)
Page 284
Revision 4.0
PA-FCHA
Fusion Call Control Handler
Note 1:
When “n” is bigger than 1, the Time Slot Sequence Integrity (TSSI) must be guaranteed at the network.
When “n” is one or more, the corresponding D channels as “n” must be designated by SW11-SW12.
SW12
Note 11ON This SW designates the D/I channel of the
Fusion-Link-Data.   (The number of D/I channels = n)
Set the corresponding SW(s) to “ON” for D/I, “OFF” for 
denial. OFF
2ON
OFF
3ON
OFF
4ON
OFF
5ON
OFF
6ON
OFF
7ON...

Page 300

ND-70182 (E) CHAPTER 3
Page 285
Revision 4.0
PA-FCHA
Fusion Call Control Handler
SWITCH 
NAMESWITCH 
NOSETTINGSTANDARD 
SETTINGDESCRIPTION
SW131ON
This SW designates the D/I channel of the 
Fusion-Link-Data.  (The number of D/I channels = n)
Set the corresponding SW(s) to “ON” for D/I, “OFF” for 
denial. OFF
2ON
OFF
3ON
OFF
4ON
OFF
5ON
OFF
6ON
OFF
7ON
OFF
8ON
OFF
SW141ON×Positive logic for the D/I CONT
OFF Negative logic for the D/I CONT