CHAPTER 3 ND-70182 (E) Page 236 Revision 4.0 PA-16LCBW Line Circuit SWITCH No. FUNCTIONSWITCH SETTINGMEANING SW16 1 OFF Fixed to OFF 2 OFF Fixed to OFF 3 OFF Fixed to OFF 4 OFF Fixed to OFF SW17 1 OFF Fixed to OFF 2 OFF Fixed to OFF 3Message Waiting LampONMessage Waiting Lamp Flashing (Controlled by Firmware) OFFMessage Waiting Lamp lit or Flashing (Selected and Controlled by Software) 4 OFF Fixed to OFF SW18 Polarity reverse or Momentary Open (Circuit #15 Only)ON Momentary open OFF Polarity...
Page 252
ND-70182 (E) CHAPTER 3 Page 237 Revision 4.0 PA-16LCBW Line Circuit 6. Switch Setting Sheet MODULE SLOT No. SWITCH NAME SWITCH SHAPE REMARKS PIMSW00 (MB)Note:Normal operating mode is down. SW10 (BNW0-7) SW11 (BNW8-15) SW14 SW15 SW16 SW17 SW18 ON 1 2 3 4 5 6 7 8ON 1 2 3 4 5 6 7 8ON 1 2 3 4ON 1 2 3 4ON 1 2 3 4ON 1 2 3 4ON OFF (RVS) (OPEN)ON
Page 253
CHAPTER 3 ND-70182 (E) Page 238 Revision 4.0 PA-16LCBW Line Circuit 7. External Interface Accommodation of the LT connector leads for this circuit card is shown in Figure 3-48. Figure 3-48 LT Connector Lead Accommodation (1/2) See also Connecting Route Diagram. 26272829303132333435363738394041 1234567891011121314151642434445464748 1718192021222349502425 232221201918171615141312111009080706050403020100 LT6 LT7 LT8 LT9 LT10 LT11LT0 LT1 LT2 LT3 LT4 LT5 23 19 15 22 18 14 21 17 13 20 16 1223 19 15 22 18...
Page 254
ND-70182 (E) CHAPTER 3 Page 239 Revision 4.0 PA-16LCBW Line Circuit Figure 3-48 LT Connector Lead Accommodation (2/2) 26272829303132333435363738394041 1234567891011121314151642434445464748 1718192021222349502425 232221201918171615141312111009080706050403020100 LT6 LT7 LT8 LT9 LT10 LT11LT0 LT1 LT2 LT3 LT4 LT5 23 19 15 22 18 14 21 17 13 20 16 1223 19 15 22 18 14 21 17 13 20 16 12 11 09 07 05 03 01 10 08 06 04 02 00 11 09 07 05 03 01 10 08 06 04 02 00 HW11 HW10 HW9 HW8 HW7 HW6 HW5 HW4 HW3 HW2 HW1 HW0...
Page 255
CHAPTER 3 ND-70182 (E) Page 240 Revision 4.0 PA-16LCBW Line Circuit Figure 3-49 Connecting Route Diagram A BL1 L2 PBXMDF Jack Analog Terminal LC Maximum 1200 [W] (inclusive of terminal resistance) Installation Cable LT Connector Connecting Route Diagram for the PA-16 LCBW (LC) is as follows.
Page 256
ND-70182 (E) CHAPTER 3 Page 241 Revision 4.0 PA-16LCBY Line Circuit PA-16LCBY Line Circuit 1. General Function The PA-16LCBY circuit card provides an interface between a maximum of 16 analog voice terminals and the system with a range of 1200 (Ohm) inclusive of terminal resistance. This card also can send “Stutter Dial Tone,” which is not a continuous tone, to an associated terminal which has no Message Waiting Lamp (MWL) instead of activating the MWL if required. In addition, polarity reverse function...
Page 257
CHAPTER 3 ND-70182 (E) Page 242 Revision 4.0 PA-16LCBY Line Circuit 3. Face Layout of Lamps, Switches and Connectors The face layout of lamps, switches on this card is shown in Figure 3-51. Figure 3-51 Face Layout of PA-16LCBY(LC) Card OPE BL15 BL0 SW00 (MB) SW10 (BNW0-7)SW11 (BNW8-15) SW14 SW15 SW16 SW17 SW19
Page 258
ND-70182 (E) CHAPTER 3 Page 243 Revision 4.0 PA-16LCBY Line Circuit 4. Lamp Indications The contents of lamp indications of this circuit card are shown in the table below. 5. Switch Settings Switches on the PA-16LCBY (LC) card have the following meanings. LAMP NAMELAMP COLORLAMP STATUS MEANING OF INDICATION OPE Green Steady LightingThe circuitry of the circuit card is operating normally. BL0 BL15GreenSteady Lighting Line loop exists. Flashing1) Ringing signal is being transmitted. Busy Lamp keeps...
Page 259
CHAPTER 3 ND-70182 (E) Page 244 Revision 4.0 PA-16LCBY Line Circuit SWITCH No. FUNCTION SWITCH SETTING MEANING SW11 (BNW8-15)Balancing Network Designation Each element on this switch corre- sponds to Circuit #8- #15.[the same as previous page] SW14 Selection of the UserSW14 -1SW14 -2SW14 -3SW14 -4User OFF ON OFF OFFNorth America Other Country (µ-Law) OFF OFF ON OFF Other Country (A-Law) OFF ON ON OFF Australia OFF OFF OFF ON Brazil OFF OFF ON ON China SW15 1North America Brazil China Other CountryOFF...
Page 260
ND-70182 (E) CHAPTER 3 Page 245 Revision 4.0 PA-16LCBY Line Circuit Note: Compromise Impedance (EIA/TIA-464B) and 600Ω. (For North America, Other Country (A/µ Law)) SWITCH No. FUNCTIONSWITCH SETTINGMEANING SW16 1 OFF Fixed to OFF 2OFFFixed to OFF 3OFFFixed to OFF 4OFFFixed to OFF SW17 1 OFFFixed to OFF 2OFFFixed to OFF 3 Message Waiting LampONMessage Waiting Lamp Flashing (Controlled by Firmware) OFFMessage Waiting Lamp lit or Flashing (Selected and Controlled by Software) 4OFFFixed to OFF SW19 1...