Page 301
CHAPTER 3 ND-70182 (E) Page 286 Revision 4.0 PA-FCHA Fusion Call Control Handler Note 2: Data speed 64 kbps is used for the T1 or E1 interface. Data speed 56 kbps is used for the T1 interface with bit stealing. Data speed 48 kbps is used for the T1 interface with both bit stealing and the Zero Code Suppression (or Bit 7 Stuffing). Note 3:When a node is set “network,” the distant node over the fusion link should be set “user,” and vice versa. 6. External Interface The cable connections among the FCH,...
Page 302
ND-70182 (E) CHAPTER 3 Page 287 Revision 4.0 PA-FCHA Fusion Call Control Handler See the following figure when multiple numbers of FCH circuit cards are connected to a 24DTR as a cascade connection. The FCH can be combined with CCH/DCH on a cascade connection. One DTI card can have a maximum of five (5) Handler circuits cascaded within the FCH card, the CCH card, and/or DCH card. Since the FCH card contains one Handler circuit per card, a maximum of five (5) FCH cards can be cascaded to a DTI card. As an...
Page 303
CHAPTER 3 ND-70182 (E) Page 288 Revision 4.0 PA-FCHA Fusion Call Control Handler 7. Switch Setting Sheet SWITCH NAME SWITCH SHAPE REMARKS MB MNT MODE SW10 SW11 SW12 SW13 SW14 ON ON OFF 8 1 2 3 4 5 6 7 8ON 1 2 3 4 5 6 7 8ON 1 2 3 4 5 6 7 8ON 1 2 3 4 5 6 7 8ON 1 2 3 4ON
Page 304
ND-70182 (E) CHAPTER 3 Page 289 Revision 4.0 PA - M 9 6 HUB PA-M96 HUB 1. General Function This circuit card provides the repeater function which is based on ANSI/IEEE 802.3. Eight (8) of the 10BASE-T ports are located on a HUB card. As seen from the functional connection diagram below, the HUB card is located between the CPR (LANI) and the FCH card. The HUB card distributes the Fusion link data onto FCH cards. Figure 3-73 Location of PA-M96 (HUB) Card in the System Note: This figure shows the...
Page 305
CHAPTER 3 ND-70182 (E) Page 290 Revision 4.0 PA - M 9 6 HUB 2. Mounting Location/Condition The PA-M96 (HUB) card can be mounted in any universal slot of PIM0 as shown below. 3. Face Layout of Lamps, Switches, and Connectors The face layout of lamps, switches, and connectors is shown in Figure 3-74. Figure 3-74 Face Layout of PA-M96 (HUB) Card 00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 PIM0 Mounting ModulePIM Universal SlotsUniversal Slots MB OPE CRS7 CRS0 SENS TP7-X TP6-X...
Page 306
ND-70182 (E) CHAPTER 3 Page 291 Revision 4.0 PA - M 9 6 HUB 4. Lamp Indications Lamp indications for this circuit card are shown in the table below. Note 1:This lamp is used to indicate the status of the TPn-X port. Therefore, the circuit card operates normally regardless of the cable polarity. Note 2:This circuit card can detect data packet collisions at a TPn-X port when it would be a collision of 2048bit- times (2.048 ms) or when the packet collides 32 times consecutively. The port is then...
Page 307
CHAPTER 3 ND-70182 (E) Page 292 Revision 4.0 PA - M 9 6 HUB 5. Switch Setting Standard settings for switches on this circuit card are shown in the table below. SWITCH NAMESETTINGSTANDARD SETTINGDESCRIPTION MBUP Circuit card Make-busy. DOWN×Circuit card Make-busy cancel. SENSE0 Polarity indication on the STn lamps for TPn-X ports (n = 0~7). 1Not used. 2×TPn-X ports operate as a repeater HUB. (n = 0~7). 3Data-Packet-Collision indication on the STn lamps for TPn-X ports (n = 0~7). 4 - F Not used
Page 308
ND-70182 (E) CHAPTER 3 Page 293 Revision 4.0 PA - M 9 6 HUB 6. External Interface 24DTR CN2FCH FCH PZ-PC19 (LANI) 10 BASE-T straight Cable 10 BASE-T straight CableHUB 10AL (10) FLT CA DTI
Page 309
CHAPTER 3 ND-70182 (E) Page 294 Revision 4.0 PA - M 9 6 HUB 7. Switch Setting Sheet SWITCH NAME SWITCH SHAPE REMARKS MB SEL ON 2
Page 310
ND-70182 (E) CHAPTER 3 Page 295 Revision 4.0 PA - 8 R S T M Register Sender Trunk PA - 8 R S T M Register Sender Trunk 1. Function This circuit card is an 8-circuit register sender trunk card that transmits and sends selective signals (DP signals, PB signals, MF signals). Figure 3-75 Location of the PA-8RSTM Card in the System ATTLC COT TLT TSW ATIStation C.O. Line Tie Line RST