Page 221

CHAPTER 3 ND-70182 (E)
Page 206
Revision 4.0
PH-CK17-A
Phase Lock Oscillator
Figure 3-31 shows an example of distributing clock from a digital interface. This figure assumes that the Digital
Trunk POUT leads are used as the first clock distribution route.
Figure 3-31   Cable Connection Diagram (4-IMG System/LN) for Receiving Clock from Digital Interface
DIU0A1
DIU0B1
DIU1A1
DIU1B1
DIU2A1
DIU2B1
DIU3A1
DIU3B1
DIU0A0
DIU0B0
DIU1A0
DIU1B0
DIU2A0
DIU2B0
DIU3A0
DIU3B0
RA
RB
TA
TB
POUT A
POUT BPCM Cable (2P)...

Page 222

ND-70182 (E) CHAPTER 3
Page 207
Revision 4.0
PH-CK17-A
Phase Lock Oscillator
Figure 3-32   Connection of External Music-On-Hold
7. Switch Setting Sheet
SWITCH NAME SWITCH SHAPE
MB
SW01
SW02
SW03
SW10
SW11
SW12
ISW-LN PLO CA-A cable/
34PH ISWM EXCLK CA-A
Pin Assignment
PIN
No.
26
27
28
29
30
31
32
33LEAD
NAME
FM1
FM0LEAD
NAME
E
E PIN
No.
1
2
3
4
5
6
7
8
9MUSIC
SOURCE MDFISW-LN PLO CA-A /
34PH ISWM EXCLK CA-A and
Installation Cable(25P)
Multiple connections between the systems 0 and 1
are required on the...

Page 223

CHAPTER 3 ND-70182 (E)
Page 208
Revision 4.0
PH-CK18
Clock
PH-CK18
Clock
1. General Function
This circuit card is used for the Local Node of the IMX-U system. The main function of this circuit card is
to supply basic clock signals to the system. This card receives clock signals from the Phase Lock Oscillator
(PLO) located in TSWM0 of IMG1, distributing the following signals to the Time Division Switch (TSW)
located in TSWM1 of IMG2.
32.768 MHz CLK
8 KHz FH
5 msec ×  “n” FH (for Wireless System) 

Page 224

ND-70182 (E) CHAPTER 3
Page 209
Revision 4.0
PH-CK18
Clock
Figure 3-33   Location of PH-CK18 (CLK) 
LN0
(IMG2/IMG3)LN3
(IMG2/IMG3)
32M, FH+WFH
PLO ACT32M, FH+WFH
PLO ACT
CLK1
(TSWM1)
TSW
10~13
CLK0
(TSWM1)
TSW
00~03
MUX
(System1)MUX
(System0)
LC/TRK
HSW00 ISW
HSW01
CLK1
(TSWM1)
TSW
10~13
CLK0
(TSWM1)
TSW
00~03
MUX
(System1)MUX
(System0)
LC/TRK
LN0
(IMG0/IMG1)from
LN DTIfrom
LN DTI
32M, FH+WFH
PLO ACT32M, FH+WFH
PLO ACT
(BWB)32M, FH+WFH
PLO ACT
(BWB)
64K+FH, WFH
TSW ACT
(Cable)64K+FH, WFH
TSW ACT
(Cable)...

Page 225

CHAPTER 3 ND-70182 (E)
Page 210
Revision 4.0
PH-CK18
Clock
2. Mounting Location/Condition
Mounting locations for this circuit card are shown below.
3. Face Layout of Lamps, Switches, and Connectors
The face layout of each lamp and switch on this circuit card is shown in Figure 3-34.
Figure 3-34   Face Layout of PH-CK18 (CLK) 00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20
21 2223
Mounting ModuleTSWM1 (IMG2)
CLK (#1)
CLK (#0)
MB OPE
ALM0
ALM1
PALM 

Page 226

ND-70182 (E) CHAPTER 3
Page 211
Revision 4.0
PH-CK18
Clock
4. Lamp Indications
Lamp indications for this circuit card are shown below:
5. Switch Settings
Switch settings for this circuit card are shown below.
LAMP COLOR  MEANING
OPE Green Lights when this circuit card is in ACT state.
ALM 0 Red Lights when clock signal failure has occurred.
ALM 1 Red Lights when Frame Head signal failure has occurred.
PALM Red Lights when the On Board Power Supply failure has occurred.
SWITCH 
NAMESETTINGSTANDARD...

Page 227

CHAPTER 3 ND-70182 (E)
Page 212
Revision 4.0
PH-CK18
Clock
6. External Interface
Figure 3-35   LT Connector Lead Location (ISW-LN0)
7. Switch Setting Sheet
SWITCH NAME SWITCH SHAPE REMARKS
MB
PIM
CLK00
(Slot No.08) CLK10
(Slot No.12)
TSWM1
TSWM0 ISWM
Installation Cable DIU Connection Note
MDF
To Digital Interface and/or DCS
EXCLK0
(Slot No.21)
PLO CLOCK0
(Slot No.21)
EXCLK1
(Slot No.23)
PLO CLOCK1
(Slot No.23)PLO CLOCK0
(Slot No.21)PLO CLOCK1
(Slot No.23)
ISW-LN PLO CA-A
PLO-CLK CA-A DCS Connection...

Page 228

ND-70182 (E) CHAPTER 3
Page 213
Revision 4.0
PA - C S 0 8
Hotel Attendant Interface
PA - C S 0 8
Hotel Attendant Interface
1. General Function
This circuit card is the Hotel Attendant Console (Hotel ATTCON) interface card that supports the interface
function for the Hotel ATTCON (maximum two sets of Hotel ATTCON per card), PM function (controlling
of Hotel ATTCON and exchanging of control commands with the CPU), PB/DP sending function (sending
of PB signals or DP signals under control of the PM),...

Page 229

CHAPTER 3 ND-70182 (E)
Page 214
Revision 4.0
PA - C S 0 8
Hotel Attendant Interface
3. Face Layout of Lamps, Switches, and Connectors
The face layout of lamps, switches, and connectors on this circuit card is shown in Figure 3-37.
Figure 3-37   Face Layout of HMATI Card
4. Lamp Indications
Lamp indications for this circuit card are shown in the table below.
LAMP COLOR  STATE
OPE Green Remains lit while this circuit card is operating.
N-OPE Red Remains lit while this circuit card is in Make-busy state....

Page 230

ND-70182 (E) CHAPTER 3
Page 215
Revision 4.0
PA - C S 0 8
Hotel Attendant Interface
5. Switch Settings
Standard settings for various switches on this circuit card are shown in the table below.
BLA0
BLA1Red Lights when the corresponding circuit is busy.
Blink Blinks when the corresponding circuit is in Make-busy state.
SWITCHSWITCH 
NO.SETTINGSTANDARD 
SETTINGMEANING
MBUP Circuit card Make-busy.
DOWNCircuit card Make-busy cancel.
SW02 (TAS0)
SW03 (TAS1)1
2
3
4
SW041ON  ×Fixed
2OFF  ×Fixed
3ON  ×Fixed
4OFF...
Start reading NEC Neax 2400 Imx Circuit Card Manual

Related Manuals for NEC Neax 2400 Imx Circuit Card Manual

All NEC manuals