Page 231
CHAPTER 3 ND-70182 (E) Page 216 Revision 4.0 PA - C S 0 8 Hotel Attendant Interface Note: When the PB signal is sent from the Hotel ATT, set the SW 12-1~4 ON, and assign AHSY command, INDEX 114, b7 = I. SWITCHSWITCH NO.SETTINGSTANDARD SETTINGMEANING SW111ON OFF×Fixed 2ON OFF×Fixed 3ON OFF×Fixed 4ON OFF×Fixed SW121ON× Fixed (all ON). OFF 2ON× OFF 3ON× OFF 4ON× OFF SW90ON No. 0 System is in Make-busy request. OFF×Normal setting. 1ON No. 1 System is in Make-busy request. OFF×Normal setting 2OFF×Not used...
Page 232
ND-70182 (E) CHAPTER 3 Page 217 Revision 4.0 PA - C S 0 8 Hotel Attendant Interface 6. External Interface The location for the LT connector leads for this circuit card is shown in Figure 3-38. Figure 3-38 LT Connector Lead Location (PIM) 23222120191817161514131211100908070605 0403020100 LT6 LT7 LT8 LT9 LT10LT0 LT1 LT2 LT3 LT4LT5 19 15 18 14 17 13 16 1223 19 15 22 18 14 21 17 13 20 16 12 11 09 07 05 03 01 10 08 06 04 02 00 11 09 07 05 03 01 10 08 06 04 02 0023 22 21 20 HMATI Group No. Slot No. PIM...
Page 233
CHAPTER 3 ND-70182 (E) Page 218 Revision 4.0 PA - C S 0 8 Hotel Attendant Interface 7. Switch Setting Sheet SWITCH SWITCH SHAPE REMARKS MBUP: Circuit card Make-busy. DOWN: Circuit card Make-busy cancel. SW02 SW03 SW04 SW07 SW08 SW09 SW9-2, SW9-3: Not used. SW11 SW12 ON 1234 1234 1234ON 1234ON 1234ON No. 3 No. 2 No. 1 No. 0 ON OFF (Piano Switch) 1234ON 1234ON
Page 234
ND-70182 (E) CHAPTER 3 Page 219 Revision 4.0 PA - C S 3 3 Attendant Interface PA - C S 3 3 Attendant Interface 1. General Function This circuit card is a Desk Console interface which supports the interface function for accommodating two sets of Desk Consoles, PB/DP sender function and Trunk Answer from any Station (TAS) function. Figure 3-39 Location of PA-CS33 (ATI) Card in the System MUX MUX MUX TSW/INT/PLO MUX CPR GT PCM HW PM BUS PCM HW PM BUS PCM HW PM BUS PCM HW PM BUS LC/TRKATI DESK CONSOLE
Page 235
CHAPTER 3 ND-70182 (E) Page 220 Revision 4.0 PA - C S 3 3 Attendant Interface 2. Mounting Location/Condition The PA-CS33 (ATI) can be mounted in either Slot 12 or 23 of the PIM. 3. Face Layout of Lamps, Switches, and Connectors The face layout of lamps, switches and connectors is shown in Figure 3-40. Figure 3-40 Face Layout of PA-CS33 (ATI) 00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 2223AT I AT I Mounting ModulePIM Universal SlotsUniversal Slots SW00 OPE 1 2 3 4 5 6 7 81...
Page 236
ND-70182 (E) CHAPTER 3 Page 221 Revision 4.0 PA - C S 3 3 Attendant Interface 4. Lamp Indications Lamp indications for this circuit card are shown in the table below. 5. Switch Setting Standard settings for switches on this circuit card are shown in the table below. LAMP NAME COLOR STATE OPEGreen Remains lit while circuit card is operating normally. OFF Off when circuit card is not operating. PA L MRed Lights when the power feeding circuit failure has occurred. OFF Off when the power feeding circuit...
Page 237
CHAPTER 3 ND-70182 (E) Page 222 Revision 4.0 PA - C S 3 3 Attendant Interface SWITCH NAMESWITCH NOSETTINGSTANDARD SETTINGMEANING SW010ON×Make-busy cancel for #0 Desk Console. OFF Make-busy request for #0 Desk Console. 1ON×Make-busy cancel for #1 Desk Console. OFF Make-busy request for #1 Desk Console. 2OFF×Not used 3OFF×Not used SW10 (TAS#0) SW13 (TAS#1)1SW10 and SW13 designate the current limit resistance for TAS#0 and TAS#1 respectively. 2 3 4This switch designates the TAS signaling system in...
Page 238
ND-70182 (E) CHAPTER 3 Page 223 Revision 4.0 PA - C S 3 3 Attendant Interface Note: DESK CONSOLE starts up in Day or Night mode according to this setting after the circuit card initializa- tion, regardless of the mode before the initialization. SWITCH NAMESWITCH NOSETTINGSTANDARD SETTINGMEANING SW161For Business system, set SW16-1 and SW16-7 to OFF. When the system has Hotel application, set SW16-1 and SW16-7 according to system data as shown below. 2ON Desk Console Expanded LCD Display available. OFF...
Page 239
CHAPTER 3 ND-70182 (E) Page 224 Revision 4.0 PA - C S 3 3 Attendant Interface 6. External Interface Location of the LT connector leads for the DESK CONSOLE interface is as shown in Figure 3-41. Figure 3-41 LT Connector Lead Location (PIM) Mounting ModulePIM 2627 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 501 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 BN4800BN4801 BN4820BN4821 BN4830 BN4831 B0 B1 B3A0 A2 A3 A1 B2 BN4810 BN4811 LT5, 11 connector 00 01 02 03 04...
Page 240
ND-70182 (E) CHAPTER 3 Page 225 Revision 4.0 PA - C S 3 3 Attendant Interface Figure 3-42 Connecting Route Diagram Note: The power feeding wires (BN4820/BN4821/BN4830/BN4831/GND) are not required when the power is supplied to the DESK CONSOLE locally. AT IB2 BN4820 BN4821 B3 BN4830 BN4831B3 BN4830 BN4831 GND GND B2 BN4820 BN4821 GND GND PBX Installation Cable A2MDF IDF 6-PIN MODULAR ROSETTE#0 DESK CONSOLE 6-PIN MODULARCABLE #1 DESK CONSOLE A2 A3 A3 GND (PZ-M377)(-48V) (-48V)