NEAX2400 IMX Business Features and Specifications NDA-24221, Issue 3 Page 471 Station Hunting - Terminal S-9 Interactions (cont’d) c.) When PH = 0: Station hunt starts by dialing the pilot station number only. The feature is not provided when the Phantom Number is dialed. 9. The lead station is the first station programmed in the ASHP command. 10. When Programmed on LDM: a.) When activating this feature via FCCS, when CALL FORWARDING - ALL CALLS [C-5] is in service at a pilot station, a call directed to...
Page 502
NEAX2400 IMX Business Features and Specifications Page 472NDA-24221, Issue 3 S-9 Station Hunting - Terminal Interactions (cont’d) g.) When using a Phantom Telephone Number (PHTELN) for the pilot station, consider the following: Whether to use the PHTELN to start the station hunt or not can be selected by the command APHNL. When using the PHTELN, assign “1” in the PH parameter. If not, assign “0”. When PH = 1: Station hunt starts by dialing either the pilot station number (telephone number) or its...
Page 503
NEAX2400 IMX Business Features and Specifications NDA-24221, Issue 3 Page 473 Station Message Detail Recording (SMDR) S-10 S-10 Station Message Detail Recording (SMDR) General Description This feature provides a call record for all outgoing station to trunk calls and incoming trunk to station calls. When the system is equipped with this feature, an RS232C output port or a SOCKET interface (LAN) is provided, permitting interface with a customer-owned computer system. All output is in the ASCII format,...
Page 504
NEAX2400 IMX Business Features and Specifications Page 474NDA-24221, Issue 3 S-10 Station Message Detail Recording (SMDR) Service Conditions (cont’d) 8. If the distance between the system and the processing computer exceeds 50 feet (15 meters), an asynchronous-type modem should be used. 9. RS232C Interface specifications: Synchronization Asynchronous Data Speed 300, 600, 1200, 2400, 4800, 9600bps Code ASCII 7-Bit + parity Bit Maximum Distance 50 ft. (15m) without modem 10. Supervision on the status of...
Page 505
NEAX2400 IMX Business Features and Specifications NDA-24221, Issue 3 Page 475 Station Message Detail Recording (SMDR) S-10 Service Conditions (cont’d) 31. Additional hardware is required. 32. Call Time specification for the FCCS network: The base for Call Start Time and Call End Time is the time in the calling party-side node. In case there is time difference between each node, related time difference data, based on the UCT (Universal Coordinated Time) standard, should be written in Network Data...
Page 506
NEAX2400 IMX Business Features and Specifications Page 476NDA-24221, Issue 3 S-10 Station Message Detail Recording (SMDR) Service Conditions (cont’d) 41. The figures on the following pages show the Service Conditions of Polling Method, focusing on when CCIS links are involved. Example 1 Node A (Fusion - Center Node) Collects the billing information of Nodes B and C via FCCS using the polling method. Example 2 Node A tries to collect the billing information of Node B and Node C via FCCS, using the...
Page 507
NEAX2400 IMX Business Features and Specifications NDA-24221, Issue 3 Page 477 Station Message Detail Recording (SMDR) S-10 Service Conditions (cont’d) Example 3 Node A tries to collect the billing information of Node B via FCCS, using the polling method (Node A cannot collect the billing information of Node B via FCCS). Node B sends the billing information via CCIS, ignoring polling from Node A. Node B deletes the Point Code (CCIS) of Node C for centralized billing data when required to send...
Page 508
NEAX2400 IMX Business Features and Specifications Page 478NDA-24221, Issue 3 S-10 Station Message Detail Recording (SMDR) Service Conditions (cont’d) Example 4 Node A collects the billing information of Node B and Node C via FCCS, using the polling method. Node A sends the billing information of Node A, Node B and Node C. Node C CCIS - Center Node non IMX SMDR EquipmentFCCS Network IMX 36456 55213 25454 75213 Billing information of Nodes A, B, C Node D IMX CCIS 79 87 9 8 46 51 38 92 5 4 65 65 Node...
Page 509
NEAX2400 IMX Business Features and Specifications NDA-24221, Issue 3 Page 479 Station Message Detail Recording (SMDR) S-10 Service Conditions (cont’d) Example 5 Node A collects the billing information of Node B and Node C via FCCS, using the polling method (Billing information of Node B cannot be collected). Node B sends the billing information to Node D via CCIS, ignoring polling from Node A. Node B deletes the Point Code (CCIS) for Node D when Node B wants to send billing information for polling...
Page 510
NEAX2400 IMX Business Features and Specifications Page 480NDA-24221, Issue 3 S-10 Station Message Detail Recording (SMDR) Service Conditions (cont’d) Example 6 Node A collects the billing information of Node B, Node C and Node D, which are stored in Node B by polling method. Node D sends the billing information to Node B. SOCKET Interface (LAN Interface) Conditions: 42. SMDR data can be output via LAN cable. 43. A maximum of four SMDR apparatuses per node are available. 44. When providing this...