Home > NEC > Communications System > NEC Neax 2400 Imx Business Features And Specifications

NEC Neax 2400 Imx Business Features And Specifications

Here you can view all the pages of manual NEC Neax 2400 Imx Business Features And Specifications. The NEC manuals for Communications System are available online for free. You can easily download all the documents as PDF.

Page 501

NEAX2400 IMX Business Features and Specifications
NDA-24221, Issue 3
Page 471
Station Hunting - Terminal S-9
Interactions (cont’d)
c.) When PH = 0: Station hunt starts by dialing the pilot station number only. The feature is not
provided when the Phantom Number is dialed.
9. The lead station is the first station programmed in the ASHP command.
10. When Programmed on LDM:
a.) When activating this feature via FCCS, when CALL FORWARDING - ALL CALLS [C-5] is in
service at a pilot station, a call directed to...

Page 502

NEAX2400 IMX Business Features and Specifications
Page 472NDA-24221, Issue 3
S-9 Station Hunting - Terminal
Interactions (cont’d)
g.) When using a Phantom Telephone Number (PHTELN) for the pilot station, consider the
following:
 Whether to use the PHTELN to start the station hunt or not can be selected by the command
APHNL. When using the PHTELN, assign “1” in the PH parameter. If not, assign “0”.
 When PH = 1: Station hunt starts by dialing either the pilot station number (telephone number)
or its...

Page 503

NEAX2400 IMX Business Features and Specifications
NDA-24221, Issue 3
Page 473
Station Message Detail Recording (SMDR) S-10
S-10  Station Message Detail Recording (SMDR)
General Description
This feature provides a call record for all outgoing station to trunk calls and incoming trunk to station calls. When
the system is equipped with this feature, an RS232C output port or a SOCKET interface (LAN) is provided,
permitting interface with a customer-owned computer system. All output is in the ASCII format,...

Page 504

NEAX2400 IMX Business Features and Specifications
Page 474NDA-24221, Issue 3
S-10 Station Message Detail Recording (SMDR)
Service Conditions (cont’d)
8. If the distance between the system and the processing computer exceeds 50 feet (15 meters), an
asynchronous-type modem should be used.
9. RS232C Interface specifications: Synchronization Asynchronous 
Data Speed 300, 600, 1200, 2400, 4800, 9600bps 
Code ASCII 7-Bit + parity Bit 
Maximum Distance 50 ft. (15m) without modem
10. Supervision on the status of...

Page 505

NEAX2400 IMX Business Features and Specifications
NDA-24221, Issue 3
Page 475
Station Message Detail Recording (SMDR) S-10
Service Conditions (cont’d)
31. Additional hardware is required.
32. Call Time specification for the FCCS network:
 The base for Call Start Time and Call End Time is the time in the calling party-side node.
 In case there is time difference between each node, related time difference data, based on the UCT
(Universal Coordinated Time) standard, should be written in Network Data...

Page 506

NEAX2400 IMX Business Features and Specifications
Page 476NDA-24221, Issue 3
S-10 Station Message Detail Recording (SMDR)
Service Conditions (cont’d)
41. The figures on the following pages show the Service Conditions of Polling Method, focusing on when
CCIS links are involved.
Example 1
 Node A (Fusion - Center Node) Collects the billing information of Nodes B and C via FCCS using the
polling method.
Example 2
 Node A tries to collect the billing information of Node B and Node C via FCCS, using the...

Page 507

NEAX2400 IMX Business Features and Specifications
NDA-24221, Issue 3
Page 477
Station Message Detail Recording (SMDR) S-10
Service Conditions (cont’d)
Example 3
 Node A tries to collect the billing information of Node B via FCCS, using the polling method (Node A
cannot collect the billing information of Node B via FCCS).
 Node B sends the billing information via CCIS, ignoring polling from Node A.
 Node B deletes the Point Code (CCIS) of Node C for centralized billing data when required to send...

Page 508

NEAX2400 IMX Business Features and Specifications
Page 478NDA-24221, Issue 3
S-10 Station Message Detail Recording (SMDR)
Service Conditions (cont’d)
Example 4
 Node A collects the billing information of Node B and Node C via FCCS, using the polling method.
 Node A sends the billing information of Node A, Node B and Node C.
Node C
CCIS - Center Node
non IMX
SMDR 
EquipmentFCCS Network
IMX
36456
55213
25454
75213
Billing information of 
Nodes A, B, C
Node D
IMX CCIS
79
87
9
8
46
51
38
92
5
4
65
65
Node...

Page 509

NEAX2400 IMX Business Features and Specifications
NDA-24221, Issue 3
Page 479
Station Message Detail Recording (SMDR) S-10
Service Conditions (cont’d)
Example 5
 Node A collects the billing information of Node B and Node C via FCCS, using the polling method (Billing
information of Node B cannot be collected).
 Node B sends the billing information to Node D via CCIS, ignoring polling from Node A.
 Node B deletes the Point Code (CCIS) for Node D when Node B wants to send billing information for
polling...

Page 510

NEAX2400 IMX Business Features and Specifications
Page 480NDA-24221, Issue 3
S-10 Station Message Detail Recording (SMDR)
Service Conditions (cont’d)
Example 6
 Node A collects the billing information of Node B, Node C and Node D, which are stored in Node B by
polling method.
 Node D sends the billing information to Node B.
 SOCKET Interface (LAN Interface) Conditions:
42. SMDR data can be output via LAN cable.
43. A maximum of four SMDR apparatuses per node are available.
44. When providing this...