Page 471
NEAX2400 IMX Business Features and Specifications NDA-24221, Issue 3 Page 441 Route Advance R-6 Interactions (cont’d) 2. TOLL RESTRICTION - 3/6 DIGIT [T-6] may be used in conjunction with ROUTE ADVANCE. Only routes of the same type may be used in ROUTE ADVANCE. Two differently labeled C.O. trunks, such as, DDD and WATS may be in the same group. 3. There is no digit translation available for this feature. The dialed digits must be usable by whatever route is available. 4. This feature is available for a...
Page 472
NEAX2400 IMX Business Features and Specifications Page 442NDA-24221, Issue 3 R-7 Remote Maintenance R-7 Remote Maintenance General Description This feature allows office data changes or reassignments to be performed without a site visit by service personnel, and can be used to detect fault tendencies before they affect service. One REMOTE MAINTENANCE center can service an unlimited amount of systems, thus reducing the amount of personnel needed to maintain each site. Operating Procedure The operation of...
Page 473
NEAX2400 IMX Business Features and Specifications NDA-24221, Issue 3 Page 443 Radio Paging R-16 R-16 Radio Paging General Description This feature allows users dialing access to customer-owned RADIO PAGING equipment and to selectively tone or voice/tone alert individuals carrying pocket RADIO PAGING receivers. The paged party may be connected to the paging party by going to the nearest telephone and dialing a unique answer-back code. Operating Procedure To page: 1. Paging user dials the RADIO PAGING...
Page 474
NEAX2400 IMX Business Features and Specifications Page 444NDA-24221, Issue 3 R-16 Radio Paging Service Conditions (cont’d) 8. If the paging user has failed to hang up within a predetermined, programmable time interval (after activation), the paging connection is forcibly released. 9. If the paged party does not answer within 30 seconds, the NEAX2400 IMX will automatically page that party again. If the paged party does not answer the second page within 30 seconds, the paging request will be cancelled from...
Page 475
NEAX2400 IMX Business Features and Specifications NDA-24221, Issue 3 Page 445 Route Restriction - Announcement R-27 R-27 Route Restriction - Announcement General Description This feature permits a station-originated call, dialed to a restricted outgoing number, to be automatically routed to a recorded announcement informing the caller that the dialed number is restricted. (TOLL RESTRICTION [T-7]) Operating Procedure No manual operation is required after this feature has been programmed in System Data....
Page 476
NEAX2400 IMX Business Features and Specifications Page 446NDA-24221, Issue 3 R-37 RS-464A PAD R-37 RS-464A PAD General Description This service is for changing the current PAD control system for the lines and external trunks to a PAD control system which conforms to the RS-464A specification. The following table outlines the comparison between the current PAD control and the RS-464A PAD control. Note:ONS: Line interface to On-Premises Line (General Telephone) OPS: Line interface to Off-Premises Line...
Page 477
NEAX2400 IMX Business Features and Specifications NDA-24221, Issue 3 Page 447 RS-464A PAD R-37 General Description (cont’d) PAD PATTERN 2 PAD PATTERN 2 PAD PATTERN 2 24 DTR with SFI 50 = 0 24 DTR with SFI 50 = 1 24DTR with APAD Setting ARTD PA D SettingTr a n s m i t PA DReceive PA DARTD PA D 2Transmit PA DReceive PA DAPAD SettingTr a n s m i t PA DReceive PA D 0-9db-3db 0ARTD, PA DARTD, PA D1 -3db +3db 1 -3db +3db 1 -3db +3db 2 -3db -3db 2 -3db -3db 2 -3db -3db 3 -6db 0db 3 -6db 0db 3...
Page 478
NEAX2400 IMX Business Features and Specifications Page 448NDA-24221, Issue 3 R-37 RS-464A PAD General Description (cont’d) In 4 Wire E+M Mode, the 8TLTR can set PAD values using switch settings and ARTD and APAD values. In the following table, P0 and P1 are assigned by setting ARTD to a value of 0, CDN 30:PAD and setting values by using Switch 1 (P0) and Switch 2 (P1). P2 and P3 are assigned by setting ARTD/APAD to a value of 5, and PAD values are set by using Switch 3 positions 1, 2, 3 and 4 (P2) and...
Page 479
NEAX2400 IMX Business Features and Specifications NDA-24221, Issue 3 Page 449 RS-464A PAD R-37 Service Conditions (cont’d) 3. An Attendant Console is regarded as an ONS. The Attendant Console will follow the PAD values assigned in ARTD. 4. If PAD data is assigned by APAD command, this data overrides other PAD data assigned by ARTD, except when switch settings on the 24DTR are set to ARTD fixed. 5. PAD settings for the 8TLTR can be set using ARTD/APAD or a combination of switch settings and ARTD/APAD. 6....
Page 480
NEAX2400 IMX Business Features and Specifications Page 450NDA-24221, Issue 3 R-49 Ringer Mute R-49 Ringer Mute General Description This feature allows a user to stop ringing by pressing the associated feature key on the Dterm. Operating Procedure 1. The Dterm user presses the RINGER MUTE key; the ringing is muted and the LED of the key lights. RING OFF is displayed for three seconds. 2. The D term user presses the RINGER MUTE key again; the ringing is recovered and the LED of the key is turned off. RING...