Page 531
NEAX2400 IMX Business Features and Specifications NDA-24221, Issue 3 Page 501 Station 5db PAD S-62 S-62 Station 5db PAD General Description This feature allows a single-line user to be affected by the 5db loss through the system on station-to-station calls. Operating Procedure No manual operation is required for this software control feature. Service Conditions 1. STATION 5db PAD [S-62] is inserted only for intra-office, two-way, station-to-station connections. 2. STATION 5db PAD is inserted into the...
Page 532
NEAX2400 IMX Business Features and Specifications Page 502NDA-24221, Issue 3 S-64 Serial Call - Loop Release S-64 Serial Call - Loop Release General Description This feature allows an ATTENDANT CONSOLE loop key to become available after setting SERIAL CALL [S-15]. Operating Procedure 1. The Attendant answers an incoming Central Office call. 2. The Attendant extends the call to the desired station, and the desired station answers. 3. The Attendant presses the SC key. The loop is now available for...
Page 533
NEAX2400 IMX Business Features and Specifications NDA-24221, Issue 3 Page 503 Split Call Forwarding S-99 S-99 Split Call Forwarding General Description This feature allows a station to set two different target stations for CALL FORWARDING-ALL CALLS (FORWARD)/BUSY LINE (FORWARD-BY)/DON’T ANSWER (FORWARD-DA), depending on whether the incoming call is from an internal station or an outside party (C.O. TIE, DID, etc.). Operating Procedure 1. Station A sets or is set for CALL FORWARDING-ALL CALLS/BUSY...
Page 534
NEAX2400 IMX Business Features and Specifications Page 504NDA-24221, Issue 3 S-99 Split Call Forwarding Operating Procedure (cont’d) To set SPLIT CALL FORWARDING using Dterm feature key: To set Call Forwarding from an individual station (Dterm): 1. Setting Call Forwarding for an incoming call from a station: a.) Confirm that the PAGE* (One-touch changeover) lamp is on; if the lamp is off, turn the lamp on by pressing the PAGE key. b.) Lift the handset or press the SPEAKER key; receive dial tone. c.)...
Page 535
NEAX2400 IMX Business Features and Specifications NDA-24221, Issue 3 Page 505 Split Call Forwarding S-99 Operating Procedure (cont’d) When the destination is an outside trunk, the Dterm displays: To cancel Call Forwarding from an individual station (Dterm): 1. Cancelling Call Forwarding for an incoming call from a station: a.) Confirm that the PAGE (One-Touch Changeover) lamp is on; if the lamp is off, turn the lamp on by pressing the PAGE key. b.) Lift the handset or press the SPEAKER key; receive...
Page 536
NEAX2400 IMX Business Features and Specifications Page 506NDA-24221, Issue 3 S-99 Split Call Forwarding Operating Procedure (cont’d) When the destination is an ATTENDANT CONSOLE, the Dterm displays: When the destination is an outside trunk, the D term displays: 2. To monitor the assigned data for station-to-station calls: a.) Confirm that the PAGE key LED on the D term is illuminated. (If it is not illuminated, press the PAGE key to turn it on.) b.) While the D term is in the idle state (on-hook), press...
Page 537
NEAX2400 IMX Business Features and Specifications NDA-24221, Issue 3 Page 507 Split Call Forwarding S-99 Operating Procedure (cont’d) b.) Dial the Tenant Number (2 digits) of the originating station and the originating telephone number. c.) Press the RELEASE key; receive service set tone. 2. Cancelling Call Forwarding for an incoming call from an outside party: a.) Press an idle loop key and dial the FORWARD, FORWARD-BY, or FORWARD-DA access code for an incoming call from an outside party; receive...
Page 538
NEAX2400 IMX Business Features and Specifications Page 508NDA-24221, Issue 3 S-99 Split Call Forwarding Service Conditions (cont’d) 11. If SPLIT CALL FORWARDING is set on a station in the hunting group (STATION HUNTING - CIRCULAR [C-7], - TERMINAL [S-9], that station is skipped in hunting. However, if the station has set SPLIT CALL FORWARDING for station-to-station calls only, the station is hunted for incoming calls from outside. If the station has set SPLIT CALL FORWARDING for outside calls only, the...
Page 539
NEAX2400 IMX Business Features and Specifications NDA-24221, Issue 3 Page 509 Slumber Time - Do Not Disturb S-106 S-106 Slumber Time - Do Not Disturb General Description This service allows a slumber time for up to four times per day on a Station group basis. During the slumber time, all stations in the group concerned are placed into Do Not Disturb mode, and incoming calls (Station/DID/DIT) will be routed to the Attendant or an announcement machine. Operating Procedure No manual operation is required....
Page 540
NEAX2400 IMX Business Features and Specifications Page 510NDA-24221, Issue 3 S-106 Slumber Time - Do Not Disturb Service Conditions (cont’d) STATION HUNTING [S-7, 9] UNIFORM CALL DISTRIBUTION [U-1] 17. CALL BACK [C-1] and CALL WAITING-ORIGINATING [C-31] can be set from a Slumber Time station. 18. Each of the following services is restricted to a Slumber Time station: CALL WAITING-ORIGINATING [C-31] CALL BACK [C-1] EXECUTIVE RIGHT-OF-WAY [E-1] 19. Each of the following terminals can access to a Slumber...