CHAPTER 2 INSTALLATION Installation for Main Site NEAX2000 IVS2 Remote PIM System Manual ND-70917 (E), Issue 1.0 Page 23 INSTALLATION FOR MAIN SITE Mounting DAIA Card for T1 / DAID Card for E1 (1) Before mounting the DAIA/DAID card, set the MB switch to UP position, and set the other switches to appropriate position. See CHAPTER 4. (2) Mount the DAIA/DAID card in the AP slots (AP00-AP11) on the Main Site PIM0, 2, 4. A maximum of three DAIA/DAID cards can be mounted. After mounting the card, set the MB switch to DOWN position. Mounting DAIC Card for T1 / DAIF Card for E1 (1) Before mounting the DAIC/DAIF card, set the MB switch to UP position, and set the other switches to appropriate position. See CHAPTER 4. (2) Mount the DAIC/DAIF card in the AP slots (AP00-AP11) on the Main Site PIM0, 2, 4. A maximum of six DAIC cards can be mounted. A maximum of three DAIF cards can be mounted. After mounting the card, set MB switch to DOWN position. (3) After mounting all DAIC/DAIF cards, set MB switch on DAIA/DAID card to UP, and then DOWN. Mounting FP Card (1) Before mounting the FP card, set the MB switch to UP position, and set the other switches to appropriate position. See CHAPTER 4. (2) Mount the FP card in the FP slot of PIM0, PIM2, PIM4 and PIM6. After mounting the card, set MB switch to DOWN position. Mounting M10 Card (1) Confirm the correct switch settings. See CHAPTER 4. (2) Mount the M10 card in any one of LT slot on each PIM. AT T E N T I O NContents Static Sensitive Handling Precautions Required
NEAX2000 IVS2 Remote PIM System ManualPage 24 ND-70917 (E), Issue 1.0 CHAPTER 2 INSTALLATION Installation for Main Site BUS Cable Connection (1) Cable Connection Between BUS Connector on the BWB and DAIA/DAID Card Connect the DAIA/DAID card to the BUS connector on the BWB by the RMT BUS CA-A, as shown in Figure 2-4. In BUS connector on the BWB, BUS1B or BUS0B of the even-numbered PIMs (PIM0, 2, 4, etc.) must be used for this connection. Figure 2-4 BUS Cable Connection (1 of 2) (a) When mounting DAIA/DAID card on PIM0 When Main PIM is 1 or 2 PIM configuration When Main PIM is 3 or 4 PIM configuration NOTE 1 PIM2 PIM 3 PIM4 PIM BUS1B BUS1A BUS0B BUS0A BUS1B BUS1A DAIA/ DAID DAIA/ DAID BUS0B BUS0A PCM1 PCM0 PIM0 PCM1 PCM0 PIM0 RMT BUS CA-A RMT BUS CA-A NOTE PIM0PIM0 PIM2PIM2 PIM0PIM0 NOTE:DAIA/DAID card must be mounted in even-numbered PIMs. When mounted in PIM0 BWB BUS connector, BUS1B or BUS0B may be used for this connection. When mounted in PIM2 or PIM4 BWB BUS connector, BUS1B must be used.
CHAPTER 2 INSTALLATION Installation for Main Site NEAX2000 IVS2 Remote PIM System Manual ND-70917 (E), Issue 1.0 Page 25 Figure 2-4 BUS Cable Connection (2 of 2) (b) When mounting DAIA/DAID card on PIM2, PIM4 When Main PIM is 5 or 6 PIM configuration, the DAIA/DAID card must be mounted on PIM2 and/or PIM4, and connected as follows: RMT BUS CA-A 5 PIM 6 PIM NOTE:DAIA/DAID card must be mounted in even-numbered PIMs. When mounted in PIM0 BWB BUS connector, BUS1B or BUS0B may be used for this connection. When mounted in PIM2 or PIM4 BWB BUS connector, BUS1B must be used. BUS1B BUS1A BUS0B BUS0A DAIA/ DAID PCM1 PCM0 PIM2/ PIM4 PIM2 PIM4 PIM2 PIM4 NOTE
NEAX2000 IVS2 Remote PIM System ManualPage 26 ND-70917 (E), Issue 1.0 CHAPTER 2 INSTALLATION Installation for Main Site (2) Cable Connection Between DAIA/DAID Cards If two or three DAIA/DAID cards are mounted on one PIM, connect between the PCM0 connector and PCM1 connector on the DAIA/DAID cards by 17-TW-0.3 CONN CA-A, as shown in Figure 2-5. Up to three DAIA/DAID cards can be connected directly by a daisy chain connection on one PIM. Figure 2-5 DAIA/DAID Between DAIA/DAID Cable Connection 17-TW-0.3 CONN CA-A PCM1 PCM0 PIM0/ PIM2/ PIM4DAIA/DAID
CHAPTER 2 INSTALLATION Installation for Main Site NEAX2000 IVS2 Remote PIM System Manual ND-70917 (E), Issue 1.0 Page 27 (3) Cable Connection Between DAIA/DAID Card and DAIC/DAIF Card Connect between the RBUS connector on the DAIC/DAIF card and the BUS connector on the DAIA/DAID card by 48-TW-0.2 CONN CA, as shown in Figure 2-6. Up to two DAIC cards can be mounted per DAIA card. Only one DAIF card can be mounted per DAID card. Figure 2-6 DAIA/DAID Between DAIC/DAIF Cable Connection (1 of 2) : 17-TW-0.3 CONN CA-A DAIC When mounting 1 DAIA/DAID card and 1 DAIC/DAIF card When mounting 2 DAIA/DAID cards and 2 DAIC/DAIF cards TBUS RBUS : 48-TW-0.2 CONN CA PCM1 PCM0 TBUS RBUS PCM1 PCM0 DAIA /DAIF /DAID DAIC DAIA /DAIF /DAIDDAIC DAIA /DAIF /DAIDBUS BUS NOTE:You can mount two DAIA/DAID cards and two DAIC/DAIF cards in PIM0 or PIM2, or one DAIA/DAID card and one DAIC/DAIF card in PIM0 and one DAIA/ DAID card and one DAIC/DAIF card in PIM2. NOTE
NEAX2000 IVS2 Remote PIM System ManualPage 28 ND-70917 (E), Issue 1.0 CHAPTER 2 INSTALLATION Installation for Main Site Figure 2-6 DAIA/DAID Between DAIC/DAIF Cable Connection (2 of 2) : 17-TW-0.3 CONN CA-A When mounting 3 DAIA/DAID cards and 3 DAIC/DAIF cards : 48-TW-0.2 CONN CA BUS TBUS RBUS PCM1 PCM0 DAIC DAIA /DAIF /DAIDDAIC DAIA /DAIF /DAIDDAIC DAIA /DAIF /DAID When mounting 3 DAIA cards and 6 DAIC cards BUS TBUS RBUS PCM1 PCM0 DAICDAIA DAICDAIA DAICDAIA
CHAPTER 2 INSTALLATION Installation for Remote Site NEAX2000 IVS2 Remote PIM System Manual ND-70917 (E), Issue 1.0 Page 29 INSTALLATION FOR REMOTE SITE Mounting DAIB Card for T1 / DAIE Card for E1 (1) Before mounting the DAIB/DAIE card, set the MB switch to UP position, and set the other switches to appropriate position. See CHAPTER 4. (2) Mount the DAIB/DAIE card in the MP slot on Remote PIM. After mounting the card, set the MB switch to DOWN position. Mounting DAIC Card for T1 / DAIF Card for E1 (1) Before mounting the DAIC/DAIF card, set the MB switch to UP position, and set the other switches to appropriate position. See CHAPTER 4. (2) Mount the DAIC/DAIF card in the AP slots (AP00-AP11) on Remote PIM. A maximum of two DAIC cards can be mounted per Remote PIM. A maximum of one DAIF card can be mounted per Remote PIM. After mounting the card, set MB switch to DOWN position. (3) After mounting all DAIC/DAIF cards, set MB switch on DAIB/DAIE card to UP, and then DOWN. Mounting M10 Card (1) Confirm the correct switch settings. See CHAPTER 4. (2) Mount the M10 card in any one of LT slot on each PIM. AT T E N T I O NContents Static Sensitive Handling Precautions Required
NEAX2000 IVS2 Remote PIM System ManualPage 30 ND-70917 (E), Issue 1.0 CHAPTER 2 INSTALLATION Installation for Remote Site BUS Cable Connection Connect between the BUS connector on the DAIB/DAIE card and the RBUS connector on the DAIC/DAIF card by the 48-TW-0.2 CONN CA, as shown in Figure 2-7. Figure 2-7 DAIB/DAIE Between DAIC/DAIF Cable Connection DAICDAIB TBUS RBUSBUS • When mounting 1 DAIC/DAIF card DAIC TBUS RBUSBUSDAIC When mounting 2 DAIC cards /DAIF/DAIE DAIB 48-TW-0.2 CONN CA 48-TW-0.2 CONN CA
CHAPTER 2 INSTALLATION Installation for Remote Site NEAX2000 IVS2 Remote PIM System Manual ND-70917 (E), Issue 1.0 Page 31 Mounting Line/Trunk Card for T1 (1) Mount line/trunk cards in the LT slots on the Remote PIM. (2) Connect the line cables by referring to Figure 2-8 and Ta b l e 2 - 1. Figure 2-8 Mounting Location of Line/Trunk Card for T1 Table 2-1 LTC Connector Accommodation for T1 LTC CONNECTOR CARD SLOT NUMBER LT C 0 LT 0 0 ~ LT 0 2 LT C 1 LT 0 3 ~ LT 0 5 LT C 2 LT 0 6 ~ LT 0 8 LT C 3 LT 0 9 ~ LT 1 1 *1 When providing only one DAIB card (Max. 23 ports): LT00~LT02 slot *2 When providing one DAIB card and one DAIC card (Max. 47 ports): LT00~LT05 slot *3 When providing one DAIB card and two DAIC cards (Max. 63 ports): LT00~LT11 slot NOTE:One port of the last 24 ports cannot be used for line/trunk because it is used for control signaling channel. LT09LT08LT07 LTC1LTC0LTC2 BWB Remote PIM FRONT AC/DC PWR LT10LT00LT01LT02LT03LT04LT05LT06LT11/FP11MP12 LTC3 DC/DC PWR PFTVM *1 *2 *3
NEAX2000 IVS2 Remote PIM System ManualPage 32 ND-70917 (E), Issue 1.0 CHAPTER 2 INSTALLATION Installation for Remote Site Figure 2-9 Location of Each LEN for T1 NOTE 1:A maximum of 63 line/trunks can be accommodated in one Remote PIM. NOTE 2:In Slot 08-11, only 4-port line/trunk cards are mountable. When the following 8-port cards are mounted in Slot 04-07, any line/trunk cards are not mountable in Slot 08-11. 8COT, 8DLC, 8LC, 8RSTA, 4DAT, CFTB, 2CSI, 2ILC When opposite DAIA card is set to FP No. 1: When opposite DAIA card is set to FP No. 2: When opposite DAIA card is set to FP No. 3: LEN SLOT No. 207 206 205 204 203 202 201 200215 214 213 212 211 210 209 208223 222 221 220 219 218 217 216231 230 229 228 227 226 225 224239 238 237 236 235 234 233 232247 246 245 244 243 242 241 240255 254 253 252 251 250 249 248263 262 261 260 259 258 257 256 239 238 237 236 247 246 245 244 255 254 253 252 263 262 261 260 LT00 LT01 LT02 LT03 LT04 LT05 LT06 LT07 LT08 LT09 LT10 LT11 NOTE 2 LEN SLOT No. 407 406 405 404 403 402 401 400415 414 413 412 411 410 409 408423 422 421 420 419 418 417 416431 430 429 428 427 426 425 424439 438 437 436 435 434 433 432447 446 445 444 443 442 441 440455 454 453 452 451 450 449 448463 462 461 460 459 458 457 456 439 438 437 436 447 446 445 444 455 454 453 452 463 462 461 460 LT00 LT01 LT02 LT03 LT04 LT05 LT06 LT07 LT08 LT09 LT10 LT11 NOTE 2 LEN SLOT No. 607 606 605 604 603 602 601 600615 614 613 612 611 610 609 608623 622 621 620 619 618 617 616631 630 629 628 627 626 625 624639 638 637 636 635 634 633 632647 646 645 644 643 642 641 640655 654 653 652 651 650 649 648663 662 661 660 659 658 657 656 639 638 637 636 647 646 645 644 655 654 653 652 663 662 661 660 LT00 LT01 LT02 LT03 LT04 LT05 LT06 LT07 LT08 LT09 LT10 LT11 NOTE 2