    							CHAPTER 2  INSTALLATION
    Installation for Main Site
    NEAX2000 IVS2 Remote PIM System Manual    
    ND-70917 (E), Issue 1.0   Page 23
    INSTALLATION FOR MAIN SITE
    Mounting DAIA Card for T1 / DAID Card for E1
    (1) Before mounting the DAIA/DAID card, set the MB switch to UP position, 
    and set the other switches to appropriate position. See CHAPTER 4.
    (2) Mount the DAIA/DAID card in the AP slots (AP00-AP11) on the Main Site PIM0, 2, 4.
    A maximum of three DAIA/DAID cards can be mounted.
    After mounting the card, set the MB switch to  DOWN position.
    Mounting DAIC Card for T1 / DAIF Card for E1
    (1) Before mounting the DAIC/DAIF card, set the MB switch to UP position, and set the other 
    switches to appropriate position. See CHAPTER 4.
    (2) Mount the DAIC/DAIF card in the AP slots (AP00-AP11) on the Main Site PIM0, 2, 4.
    A maximum of six DAIC cards can be mounted.
    A maximum of three DAIF cards can be mounted.
    After mounting the card, set MB switch to DOWN position.
    (3) After mounting all DAIC/DAIF cards, set MB switch on DAIA/DAID card to UP, and then 
    DOWN.
    Mounting FP Card
    (1) Before mounting the FP card, set the MB switch to UP position, and set the other switches 
    to appropriate position. See CHAPTER 4.
    (2) Mount the FP card in the FP slot of PIM0, PIM2, PIM4 and PIM6.
    After mounting the card, set MB switch to DOWN position.
    Mounting M10 Card
    (1) Confirm the correct switch settings. See CHAPTER 4.
    (2) Mount the M10 card in any one of LT slot on each PIM.
    AT T E N T I O NContents
    Static Sensitive
    Handling
    Precautions Required 
    						
    							 NEAX2000 IVS2 Remote PIM System ManualPage 24  ND-70917 (E), Issue 1.0
    CHAPTER 2  INSTALLATION
    Installation for Main Site
    BUS Cable Connection
    (1) Cable Connection Between BUS Connector on the BWB and DAIA/DAID Card
    Connect the DAIA/DAID card to the BUS connector on the BWB by the RMT BUS CA-A, as 
    shown in Figure 2-4.
    In BUS connector on the BWB, BUS1B or BUS0B of the even-numbered PIMs (PIM0, 2, 4, 
    etc.) must be used for this connection.
    Figure 2-4  BUS Cable Connection (1 of 2)
    (a) When mounting DAIA/DAID card on PIM0
    When Main PIM is 1 or 2 PIM configuration 
    When Main PIM is 3 or 4 PIM configuration 
    NOTE
    1 PIM2 PIM
    3 PIM4 PIM
    BUS1B 
    BUS1A
    BUS0B 
    BUS0A
    BUS1B 
    BUS1A DAIA/ 
    DAID
    DAIA/ 
    DAID
    BUS0B 
    BUS0A PCM1
    PCM0
    PIM0
    PCM1
    PCM0
    PIM0
    RMT BUS CA-A
    RMT BUS CA-A
    NOTE
    PIM0PIM0
    PIM2PIM2
    PIM0PIM0
    NOTE:DAIA/DAID card must be mounted in even-numbered PIMs. When mounted in
    PIM0 BWB BUS connector, BUS1B or BUS0B may be used for this connection.
    When mounted in PIM2 or PIM4 BWB BUS connector, BUS1B must be used. 
    						
    							CHAPTER 2  INSTALLATION
    Installation for Main Site
    NEAX2000 IVS2 Remote PIM System Manual    
    ND-70917 (E), Issue 1.0   Page 25
    Figure 2-4  BUS Cable Connection (2 of 2)
    (b) When mounting DAIA/DAID card on PIM2, PIM4
    When Main PIM is 5 or 6 PIM configuration, the DAIA/DAID card must be mounted 
    on PIM2 and/or PIM4, and connected as follows:
    RMT BUS CA-A
    5 PIM
    6 PIM
    NOTE:DAIA/DAID card must be mounted in even-numbered PIMs. When mounted in
    PIM0 BWB BUS connector, BUS1B or BUS0B may be used for this connection.
    When mounted in PIM2 or PIM4 BWB BUS connector, BUS1B must be used.
    BUS1B 
    BUS1A
    BUS0B 
    BUS0A DAIA/ 
    DAID PCM1
    PCM0
    PIM2/ 
    PIM4
    PIM2
    PIM4
    PIM2
    PIM4
    NOTE 
    						
    							 NEAX2000 IVS2 Remote PIM System ManualPage 26  ND-70917 (E), Issue 1.0
    CHAPTER 2  INSTALLATION
    Installation for Main Site
    (2) Cable Connection Between DAIA/DAID Cards
    If two or three DAIA/DAID cards are mounted on one PIM, connect between the PCM0 
    connector and PCM1 connector on the DAIA/DAID cards by 17-TW-0.3 CONN CA-A, as 
    shown in Figure 2-5.
    Up to three DAIA/DAID cards can be connected directly by a daisy chain connection on one 
    PIM.
    Figure 2-5  DAIA/DAID Between DAIA/DAID Cable Connection
    17-TW-0.3 CONN CA-A
    PCM1
    PCM0 PIM0/ 
    PIM2/ 
    PIM4DAIA/DAID 
    						
    							CHAPTER 2  INSTALLATION
    Installation for Main Site
    NEAX2000 IVS2 Remote PIM System Manual    
    ND-70917 (E), Issue 1.0   Page 27
    (3) Cable Connection Between DAIA/DAID Card and DAIC/DAIF Card
    Connect between the RBUS connector on the DAIC/DAIF card and the BUS connector on 
    the DAIA/DAID card by 48-TW-0.2 CONN CA, as shown in Figure 2-6.
    Up to two DAIC cards can be mounted per DAIA card.
    Only one DAIF card can be mounted per DAID card.
    Figure 2-6  DAIA/DAID Between DAIC/DAIF Cable Connection (1 of 2)
    : 17-TW-0.3 CONN CA-A DAIC
    When mounting 1 DAIA/DAID card and 1 DAIC/DAIF card
    When mounting 2 DAIA/DAID cards and 2 DAIC/DAIF cards
    TBUS
    RBUS
    : 48-TW-0.2 CONN CA
    PCM1
    PCM0
    TBUS
    RBUS
    PCM1
    PCM0
    DAIA
    /DAIF /DAID
    DAIC DAIA
    /DAIF /DAIDDAIC DAIA
    /DAIF /DAIDBUS
    BUS
    NOTE:You can mount two DAIA/DAID cards and two DAIC/DAIF cards in PIM0 or
    PIM2, or one DAIA/DAID card and one DAIC/DAIF card in PIM0 and one DAIA/
    DAID card and one DAIC/DAIF card in PIM2.
    NOTE 
    						
    							 NEAX2000 IVS2 Remote PIM System ManualPage 28  ND-70917 (E), Issue 1.0
    CHAPTER 2  INSTALLATION
    Installation for Main Site
    Figure 2-6  DAIA/DAID Between DAIC/DAIF Cable Connection (2 of 2)
    : 17-TW-0.3 CONN CA-A
    When mounting 3 DAIA/DAID cards and 3 DAIC/DAIF cards
    : 48-TW-0.2 CONN CA
    BUS
    TBUS
    RBUS
    PCM1
    PCM0
    DAIC DAIA
    /DAIF /DAIDDAIC DAIA
    /DAIF /DAIDDAIC DAIA
    /DAIF /DAID
    When mounting 3 DAIA cards and 6 DAIC cards
    BUS
    TBUS
    RBUS
    PCM1
    PCM0
    DAICDAIA DAICDAIA DAICDAIA 
    						
    							CHAPTER 2  INSTALLATION
    Installation for Remote Site
    NEAX2000 IVS2 Remote PIM System Manual    
    ND-70917 (E), Issue 1.0   Page 29
    INSTALLATION FOR REMOTE SITE
    Mounting DAIB Card for T1 / DAIE Card for E1
    (1) Before mounting the DAIB/DAIE card, set the MB switch to UP position, 
    and set the other switches to appropriate position. See CHAPTER 4.
    (2) Mount the DAIB/DAIE card in the MP slot on Remote PIM.
    After mounting the card, set the MB switch to  DOWN position.
    Mounting DAIC Card for T1 / DAIF Card for E1
    (1) Before mounting the DAIC/DAIF card, set the MB switch to UP position, and set the other 
    switches to appropriate position. See CHAPTER 4.
    (2) Mount the DAIC/DAIF card in the AP slots (AP00-AP11) on Remote PIM.
    A maximum of two DAIC cards can be mounted per Remote PIM.
    A maximum of one DAIF card can be mounted per Remote PIM.
    After mounting the card, set MB switch to DOWN position.
    (3) After mounting all DAIC/DAIF cards, set MB switch on DAIB/DAIE card to  UP, and then 
    DOWN.
    Mounting M10 Card
    (1) Confirm the correct switch settings. See CHAPTER 4.
    (2) Mount the M10 card in any one of LT slot on each PIM.
    AT T E N T I O NContents
    Static Sensitive
    Handling
    Precautions Required 
    						
    							 NEAX2000 IVS2 Remote PIM System ManualPage 30  ND-70917 (E), Issue 1.0
    CHAPTER 2  INSTALLATION
    Installation for Remote Site
    BUS Cable Connection
    Connect between the BUS connector on the DAIB/DAIE card and the RBUS connector on the
    DAIC/DAIF card by the 48-TW-0.2 CONN CA, as shown in Figure 2-7.
    Figure 2-7  DAIB/DAIE Between DAIC/DAIF Cable Connection
    DAICDAIB
    TBUS
    RBUSBUS
    • When mounting 1 DAIC/DAIF card
    DAIC
    TBUS
    RBUSBUSDAIC
     When mounting 2 DAIC cards
    /DAIF/DAIE
    DAIB 48-TW-0.2 CONN CA
    48-TW-0.2 CONN CA 
    						
    							CHAPTER 2  INSTALLATION
    Installation for Remote Site
    NEAX2000 IVS2 Remote PIM System Manual    
    ND-70917 (E), Issue 1.0   Page 31
    Mounting Line/Trunk Card for T1
    (1) Mount line/trunk cards in the LT slots on the Remote PIM.
    (2) Connect the line cables by referring to Figure 2-8 and Ta b l e  2 - 1.
    Figure 2-8  Mounting Location of Line/Trunk Card for T1
    Table 2-1  LTC Connector Accommodation for T1
    LTC CONNECTOR CARD SLOT NUMBER
    LT C 0 LT 0 0 ~ LT 0 2
    LT C 1 LT 0 3 ~ LT 0 5
    LT C 2 LT 0 6 ~ LT 0 8
    LT C 3 LT 0 9 ~ LT 1 1
    *1 When providing only one DAIB card (Max. 23 ports): LT00~LT02 slot
    *2 When providing one DAIB card and one DAIC card (Max. 47 ports): LT00~LT05 slot
    *3 When providing one DAIB card and two DAIC cards (Max. 63 ports): LT00~LT11 slot
    NOTE:One port of the last 24 ports cannot be used for line/trunk because it is used for
    control signaling channel.
    LT09LT08LT07
    LTC1LTC0LTC2
    BWB
    Remote PIM
    FRONT
    AC/DC
    PWR
    LT10LT00LT01LT02LT03LT04LT05LT06LT11/FP11MP12
    LTC3
    DC/DC
    PWR
    PFTVM
    *1
    *2
    *3 
    						
    							 NEAX2000 IVS2 Remote PIM System ManualPage 32  ND-70917 (E), Issue 1.0
    CHAPTER 2  INSTALLATION
    Installation for Remote Site
    Figure 2-9  Location of Each LEN for T1
    NOTE 1:A maximum of 63 line/trunks can be accommodated in one Remote PIM.
    NOTE 2:In Slot 08-11, only 4-port line/trunk cards are mountable.
    When the following 8-port cards are mounted in Slot 04-07, any line/trunk cards
    are not mountable in Slot 08-11.
    8COT, 8DLC, 8LC, 8RSTA, 4DAT, CFTB, 2CSI, 2ILC  When opposite DAIA card is set to FP No. 1:
     When opposite DAIA card is set to FP No. 2:
     When opposite DAIA card is set to FP No. 3:
    LEN
    SLOT No.
    207 
    206 
    205 
    204 
    203 
    202 
    201 
    200215 
    214 
    213 
    212 
    211 
    210 
    209 
    208223 
    222 
    221 
    220 
    219 
    218 
    217 
    216231 
    230 
    229 
    228 
    227 
    226 
    225 
    224239 
    238 
    237 
    236 
    235 
    234 
    233 
    232247 
    246 
    245 
    244 
    243 
    242 
    241 
    240255 
    254 
    253 
    252 
    251 
    250 
    249 
    248263 
    262 
    261 
    260 
    259 
    258 
    257 
    256 
     
     
    239 
    238 
    237 
    236 
     
     
    247 
    246 
    245 
    244 
     
     
    255 
    254 
    253 
    252 
     
     
    263 
    262 
    261 
    260
    LT00 LT01 LT02 LT03 LT04 LT05 LT06 LT07 LT08 LT09 LT10 LT11
    NOTE 2
    LEN
    SLOT No.
    407 
    406 
    405 
    404 
    403 
    402 
    401 
    400415 
    414 
    413 
    412 
    411 
    410 
    409 
    408423 
    422 
    421 
    420 
    419 
    418 
    417 
    416431 
    430 
    429 
    428 
    427 
    426 
    425 
    424439 
    438 
    437 
    436 
    435 
    434 
    433 
    432447 
    446 
    445 
    444 
    443 
    442 
    441 
    440455 
    454 
    453 
    452 
    451 
    450 
    449 
    448463 
    462 
    461 
    460 
    459 
    458 
    457 
    456 
     
     
     
    439 
    438 
    437 
    436 
     
     
     
    447 
    446 
    445 
    444 
     
     
     
    455 
    454 
    453 
    452 
     
     
     
    463 
    462 
    461 
    460
    LT00 LT01 LT02 LT03 LT04 LT05 LT06 LT07 LT08 LT09 LT10 LT11
    NOTE 2
    LEN
    SLOT No.
    607 
    606 
    605 
    604 
    603 
    602 
    601 
    600615 
    614 
    613 
    612 
    611 
    610 
    609 
    608623 
    622 
    621 
    620 
    619 
    618 
    617 
    616631 
    630 
    629 
    628 
    627 
    626 
    625 
    624639 
    638 
    637 
    636 
    635 
    634 
    633 
    632647 
    646 
    645 
    644 
    643 
    642 
    641 
    640655 
    654 
    653 
    652 
    651 
    650 
    649 
    648663 
    662 
    661 
    660 
    659 
    658 
    657 
    656 
     
     
    639 
    638 
    637 
    636 
     
     
    647 
    646 
    645 
    644 
     
     
    655 
    654 
    653 
    652 
     
     
    663 
    662 
    661 
    660
    LT00 LT01 LT02 LT03 LT04 LT05 LT06 LT07 LT08 LT09 LT10 LT11
    NOTE 2 
    						