Home > NEC > Communications System > NEC Neax 2000 Ivs2 Remote Pim System Manual

NEC Neax 2000 Ivs2 Remote Pim System Manual

    Download as PDF Print this page Share this page

    Have a look at the manual NEC Neax 2000 Ivs2 Remote Pim System Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 1168 NEC manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							ND-70917 (E)
    ISSUE 1
    STOCK # 151973
    Remote PIM System Manual
    ®
    FEBRUARY, 2000
    NEC America, Inc. 
    						
    							LIABILITY DISCLAIMER
    NEC America, Inc. reserves the right to change the specifications,
    functions, or features, at any time, without notice.
    NEC America, Inc. has prepared this document for use by its
    employees and customers. The information contained herein is
    the property of NEC America, Inc. and shall not be reproduced
    without prior written approval from NEC America, Inc.
    NEAX is a registered trademark of NEC Corporation.
    Copyright 2000
    NEC America, Inc.
    Printed in U.S.A. 
    						
    							ISSUE 1 ISSUE 2 ISSUE 3 ISSUE 4
    DATE FEBRUARY, 2000 DATE DATE DATE
    ISSUE 5 ISSUE 6 ISSUE 7 ISSUE 8
    DAT E DATE DAT E DAT E
    NEAX2000 IVS2
    Remote PIM System ManualRevision Sheet 1/2
    ND-70917 (E)
    PA G E  N o .ISSUE No.12345678
    i1
    ii1
    iii1
    iv
    1
    11
    21
    31
    4
    1
    51
    61
    71
    8
    1
    91
    101
    111
    12
    1
    131
    141
    151
    16
    1
    171
    181
    191
    20
    1
    211
    221
    231
    24
    1
    251
    261
    271
    28
    1
    291
    301
    311
    32
    1
    331
    341
    351
    36
    1
    371
    381
    391
    40
    1
    411
    421
    431
    44
    1
    451
    461
    471
    48
    1
    491
    501
    511
    52
    1
    531
    541
    551
    56
    1
    571
    581
    591
    60
    1
    611
    621
    631
    64
    1
    651
    661
    671
    68
    1
    691
    701
    711
    72
    1 PA G E  N o .ISSUE No.
    12345678 
    						
    							ISSUE 1 ISSUE 2 ISSUE 3 ISSUE 4
    DATE FEBRUARY, 2000 DATE DATE DATE
    ISSUE 5 ISSUE 6 ISSUE 7 ISSUE 8
    DAT E DATE DAT E DAT E
    NEAX2000 IVS2
    Remote PIM System ManualRevision Sheet 2/2
    ND-70917 (E)
    731
    741
    751
    76
    1
    771
    781
    791
    80
    1
    811
    821
    831
    84
    1
    851
    861
    871
    88
    1
    891
    901
    911
    92
    1
    931
    941
    951
    96
    1
    971
    981
    PA G E  N o .ISSUE No.12345678PA G E  N o .ISSUE No.12345678 
    						
    							NEAX2000 IVS2 Remote PIM System Manual    
    ND-70917 (E), Issue 1.0   Page i
    NEAX2000 IVS2
    Remote PIM System Manual
    TABLE OF CONTENTS
    Page
    LIST OF FIGURES  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iii
    LIST OF TABLES  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iv
    INTRODUCTION   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .    1
    PURPOSE  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  . .  1
    USING THIS MANUAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  1
    REFERENCE MANUALS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  2
    CHAPTER 1 GENERAL INFORMATION  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   3
    SYSTEM OUTLINE  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  4
    PIM CONFIGURATION  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
    SYSTEM CONFIGURATION  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  6
    System Configuration for T1   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  6
    System Configuration for E1   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  7
    REQUIRED EQUIPMENT  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  8
    SYSTEM CAPACITY  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  10
    System Capacity for T1  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
    System Capacity for E1  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
    SYSTEM CONDITIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
    TIME SLOT ALLOCATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
    Time Slot Allocation for T1  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
    Time Slot Allocation for E1   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
    CHAPTER 2 INSTALLATION  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   17
    PRECAUTIONS  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  18
    Static Electricity Guard   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  18
    INSTALLATION PROCEDURE  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  21
    Installation Procedure for Main Site  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  21
    Installation Procedure for Remote Site   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  22
    INSTALLATION FOR MAIN SITE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  23
    Mounting DAIA Card for T1 / DAID Card for E1   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  23
    Mounting DAIC Card for T1 / DAIF Card for E1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  23
    Mounting FP Card  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  23
    Mounting M10 Card  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
    BUS Cable Connection   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
    INSTALLATION FOR REMOTE SITE  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  29
    Mounting DAIB Card for T1 / DAIE Card for E1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  29
    Mounting DAIC Card for T1 / DAIF Card for E1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  29
    Mounting M10 Card  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
    BUS Cable Connection   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
    Mounting Line/Trunk Card for T1  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  31 
    						
    							 NEAX2000 IVS2 Remote PIM System ManualPage ii  ND-70917 (E), Issue 1.0
    TABLE OF CONTENTS
    Page
    Mounting Line/Trunk Card for E1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  35
    Power Failure Transfer (AUC)  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  39
    Power Failure Transfer (8PFT)   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  42
    CONNECTION BETWEEN MAIN SITE AND REMOTE SITE  . . . . . . . . . . . . . . . . . . . . . . . . . . .  47
    DAI Connection at Main Site  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  47
    DAI Connection at Remote Site  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  50
    Optical Cable Connection   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
    MP RESET . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  . .  55
    CHAPTER 3 TROUBLESHOOTING  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   57
    CHAPTER 4 CIRCUIT CARD INFORMATION  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   65
    HOW TO READ THIS CHAPTER. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  66
    MOUNTING LOCATION OF CIRCUIT CARD  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  67
    LIST OF REQUIRED CARDS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  68
    PN-CP15 (FP)   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  69
    PN-DAIA (DAI)  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  71
    PN-DAIB (DAI)  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  76
    PN-DAIC (DAI)  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  80
    PN-DAID (DAI)  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  83
    PN-DAIE (DAI)  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  89
    PN-DAIF (DAI)  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  93
    PN-M10 (M10)  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  97 
    						
    							LIST OF FIGURES
    Figure TitlePage
    NEAX2000 IVS2 Remote PIM System Manual    
    ND-70917 (E), Issue 1.0   Page iii
    Figure 1-1 Outline of Remote PIM System  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  4
    Figure 1-2 System Configuration for T1   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  6
    Figure 1-3 System Configuration for E1   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  7
    Figure 1-4 Time Slot Allocation for T1 (1 of 2)   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  13
    Figure 1-4 Time Slot Allocation for T1 (2 of 2)   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
    Figure 1-5 Time Slot Allocation for E1   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
    Figure 2-1 Static Electricity Guard (1 of 2)   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
    Figure 2-1 Static Electricity Guard (2 of 2)   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19
    Figure 2-2 Installation Procedure for Main Site  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  21
    Figure 2-3 Installation Procedure for Remote Site   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  22
    Figure 2-4 BUS Cable Connection (1 of 2)  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  24
    Figure 2-4 BUS Cable Connection (2 of 2)  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
    Figure 2-5 DAIA/DAID Between DAIA/DAID Cable Connection  . . . . . . . . . . . . . . . . . . . . . . . . . .  26
    Figure 2-6 DAIA/DAID Between DAIC/DAIF Cable Connection (1 of 2)  . . . . . . . . . . . . . . . . . . . .  27
    Figure 2-6 DAIA/DAID Between DAIC/DAIF Cable Connection (2 of 2)  . . . . . . . . . . . . . . . . . . . . 28
    Figure 2-7 DAIB/DAIE Between DAIC/DAIF Cable Connection  . . . . . . . . . . . . . . . . . . . . . . . . . .  30
    Figure 2-8 Mounting Location of Line/Trunk Card for T1   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  31
    Figure 2-9 Location of Each LEN for T1  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  32
    Figure 2-10 LTC Connector Pin Arrangement for T1 (1 of 2)   . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  33
    Figure 2-10 LTC Connector Pin Arrangement for T1 (2 of 2)   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
    Figure 2-11 Mounting Location of Line/Trunk Card for E1   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  35
    Figure 2-12 Location of Each LEN for E1  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  36
    Figure 2-13 LTC Connector Pin Arrangement for E1 (1 of 2)  . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  37
    Figure 2-13 LTC Connector Pin Arrangement for E1 (2 of 2)  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
    Figure 2-14 PFT Connection Outline (AUC)  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  39
    Figure 2-15 MDF Cross Connection for PFT (AUC) (1 of 2)  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  40
    Figure 2-15 MDF Cross Connection for PFT (PN-AUC) (2 of 2)  . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
    Figure 2-16 PFT Connection Outline (8PFT)   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  42
    Figure 2-17 Connection of 25-Pair Cable and PZ-8PFTB  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  43
    Figure 2-18 PFT Connector Pin Assignment   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  44
    Figure 2-19 MDF Cross Connection for PFT (8PFT) (1 of 2)   . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  45
    Figure 2-20 MDF Cross Connection for PFT (8PFT) (2 of 2)   . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  46
    Figure 2-21 DAI Cable Connection via LTC Connector (Main Site)   . . . . . . . . . . . . . . . . . . . . . . . .  47
    Figure 2-22 Example of DAI MDF Cross Connection via LTC Connector (Main Site)   . . . . . . . . . .  48
    Figure 2-23 DAI Cable Connection via CN Connector (Main Site)  . . . . . . . . . . . . . . . . . . . . . . . . .  49
    Figure 2-24 DAI Cable Connection via CN Connector (Remote Site) . . . . . . . . . . . . . . . . . . . . . . .  50
    Figure 2-25 Outline of Optical Cable Connection  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  51
    Figure 2-26 Example of M10 MDF Cross Connection via LTC Connector (Main Site) (1 of 2)  . . . .  52
    Figure 2-26 Example of M10 MDF Cross Connection via LTC Connector (Main Site) (2 of 2)  . . . . 53
    Figure 2-27 Example of M10 MDF Cross Connection via CN Connector (Remote Site) (1 of 2)  . .  54
    Figure 2-27 Example of M10 MDF Cross Connection via CN Connector (Remote Site) (2 of 2)  . . 55
    Figure 4-1 Mounting Location of Circuit Card  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  67 
    						
    							 NEAX2000 IVS2 Remote PIM System ManualPage iv  ND-70917 (E), Issue 1.0
    LIST OF TABLES
    Table TitlePage
    Table 1-1 PIM Configuration   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  5
    Table 1-2 Required Equipment   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
    Table 1-3 System Capacity for T1  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
    Table 1-4 System Capacity for E1  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
    Table 2-1 LTC Connector Accommodation for T1  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  31
    Table 2-2 LTC Connector Accommodation for E1  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  35
    Table 3-1 Remedial Action on Each Lamp Status  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  58
    Table 4-1 List of Required Cards  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68 
    						
    							INTRODUCTION
    Purpose
    NEAX2000 IVS2 Remote PIM System Manual    
    ND-70917 (E), Issue 1.0   Page 1
    INTRODUCTION
    PURPOSE
    This manual explains the system outline and installation procedure for providing the Remote PIM
    to the NEAX2000 IVS
    2.
    USING THIS MANUAL
    This manual contains the following chapters:
    CHAPTER 1 GENERAL INFORMATION
    This chapter explains the outline of system configuration, required equipment, system capacity,
    system conditions, and time slot allocation.
    CHAPTER 2 INSTALLATION
    This chapter explains how to install the Remote PIM hardware. This chapter describes only the
    installation procedure required for providing the Remote PIM System. Refer to the Installation
    Procedure Manual for general installation procedures.
    CHAPTER 3 TROUBLESHOOTING
    This chapter explains the method for fault diagnosis and troubleshooting when maintenance per-
    sonnel detect fault occurrences by lamp indication on DAIA/DAIB/DAIC/DAID/DAIE/DAIF and
    M10 cards. For other system faults, refer to the Maintenance Manual.
    CHAPTER 4 CIRCUIT CARD INFORMATION
    This chapter explains the mounting location, the meaning of lamp indications, and the method of
    switch settings of each circuit card for the Remote PIM. 
    						
    							 NEAX2000 IVS2 Remote PIM System ManualPage 2  ND-70917 (E), Issue 1.0
    INTRODUCTION
    Reference Manuals
    REFERENCE MANUALS
    Refer to the following manuals during installation:
    Installation Procedure Manual Provides the installation procedures for the PBX system.
    Command Manual Describes the Customer Administration Terminal (CAT)
    operation, command function, and setting data required for
    programming the PBX system.
    Office Data Programming Manual Contains the Customer Specification Sheets and Office
    Data Programming Sheets.
    Maintenance Manual Describes the maintenance service features and the
    recommended troubleshooting procedures. 
    						
    All NEC manuals Comments (0)

    Related Manuals for NEC Neax 2000 Ivs2 Remote Pim System Manual