CHAPTER 1 GENERAL INFORMATION Time Slot Allocation NEAX2000 IVS2 Remote PIM System Manual ND-70917 (E), Issue 1.0 Page 13 TIME SLOT ALLOCATION Time Slot Allocation for T1 One time slot out of the last 24 time slots provided by DAIA-DAIB connection is used for the con- trol signaling channel. Figure 1-4 shows the examples of time slot allocation when mounting 8- port cards to the PIM. Figure 1-4 Time Slot Allocation for T1 (1 of 2) (a) When using 1 DAIA card and 1 DAIB card (b) When using 1 DAIA card, 1 DAIB card and 2 DAIC cards NOTE:Control signaling channel is set by SW2 of DAIA/DAIB card. See CHAPTER 4 for the switch settings. LT00 LT01 LT02 LT03 LT04 LT05 LT06 LT07 LT08 LT09 LT10LT11 DAIB DAIA 23 Time Slots for Line/Trunks 1 Time Slot for Control Signaling Channel NOTE 23 Time Slots for Line/Trunks 1 Time Slot for Control Signaling Channel NOTE Max. 47 Time Slots for Line/Trunks per Remote Site Remote PIM Main PIM00-23 LT00 LT01 LT02 LT03 LT04 LT05 LT06 LT07 LT08 LT09 LT10LT11 DAIC DAIC 24 Time Slots for Line/Trunks Remote PIM Main PIM00-23 DAIB DAIA 24-47 Highway Channel Highway ChannelTDSW TDSW
NEAX2000 IVS2 Remote PIM System ManualPage 14 ND-70917 (E), Issue 1.0 CHAPTER 1 GENERAL INFORMATION Time Slot Allocation Figure 1-4 Time Slot Allocation for T1 (2 of 2) (c) When using 1 DAIA card, 1 DAIB card and 4 DAIC cards NOTE:Control signaling channel is set by SW2 of DAIA/DAIB card. See CHAPTER 4 for the switch settings. LT00 LT01 LT02 LT03 LT04 LT05 LT06 LT07 LT08 LT09 LT10LT11 DAIC 0DAIC 1DAIB DAIC 0DAIC 1DAIA TDSW 23 Time Slots for Line/Trunks 1 Time Slot for Control Signaling Channel NOTE 24 Time Slots for Line/Trunks 24 Time Slots for Line/Trunks Max. 63 Time Slots for Line/Trunks per Remote Site Remote PIM Main PIM00-23 24-47 48-63 Highway Channel
CHAPTER 1 GENERAL INFORMATION Time Slot Allocation NEAX2000 IVS2 Remote PIM System Manual ND-70917 (E), Issue 1.0 Page 15 Time Slot Allocation for E1 One time slot out of the last 32 time slots provided by DAID-DAIE connection is used for the con- trol signaling channel. Figure 1-5 shows examples of time slot allocation when mounting 8-port cards to the PIM. Figure 1-5 Time Slot Allocation for E1 (a) When using 1 DAID card and 1 DAIE card (b) When using 1 DAID card, 1 DAIE card and 2 DAIF cards NOTE:Control signaling channel is set by SW2 of DAID/DAIE card. See CHAPTER 4 for the switch settings. LT00 LT01 LT02 LT03 LT04 LT05 LT06 LT07 LT08 LT09 LT10LT11 DAIE DAID 30 Time Slots for Line/Trunks 1 Time Slot for Control Signaling Channel NOTE 30 Time Slots for Line/Trunks 1 Time Slot for Control Signaling Channel NOTE Max. 60 Time Slots for Line/Trunks per Remote Site Remote PIM Main PIM00-29 LT00 LT01 LT02 LT03 LT04 LT05 LT06 LT07 LT08 LT09 LT10LT11 DAIF DAIF 30 Time Slots for Line/Trunks Remote PIM Main PIM00-29 DAIE DAID 30-59 Highway Channel Highway ChannelTDSW TDSW
NEAX2000 IVS2 Remote PIM System ManualPage 16 ND-70917 (E), Issue 1.0 This page is for your notes.
NEAX2000 IVS2 Remote PIM System Manual ND-70917 (E), Issue 1.0 Page 17 CHAPTER 2 INSTALLATION This chapter explains how to install the Remote PIM hardware. This chapter describes only the installation procedures required for the Re- mote PIM System. Refer to the Installation Procedure Manual for general installation procedures.
NEAX2000 IVS2 Remote PIM System ManualPage 18 ND-70917 (E), Issue 1.0 CHAPTER 2 INSTALLATION Precautions PRECAUTIONS Static Electricity Guard You must wear a grounded wrist strap to protect circuit cards from static electricity. Figure 2-1 Static Electricity Guard (1 of 2) WHEN PLUGGING/UNPLUGGING A CIRCUIT CARD WHEN HOLDING A CIRCUIT CARD PBX WRIST STRAP FRAME GROUND SCREW CARD FRONT NEVER TOUCH THE COMPONENTS OR SOLDERED SURFACE WITH BARE HANDS.
CHAPTER 2 INSTALLATION Precautions NEAX2000 IVS2 Remote PIM System Manual ND-70917 (E), Issue 1.0 Page 19 Figure 2-1 Static Electricity Guard (2 of 2) WHEN MAKING A SWITCH SETTING ON A CIRCUIT CARD WHEN CARRYING A CIRCUIT CARD The mark shown below is attached to the sheet for the work in which circuit cards are handled. When engaging in such work, the installer must be careful not to cause damage by static elec- tricity. WEAR A WRIST STRAP AND PERFORM THE WORK ON A GROUNDED CONDUCTIVE WORK SURFACE. CIRCUIT CARD WHEN CARRYING A CIRCUIT CARD AROUND, KEEP THE CARD IN A CONDUCTIVE POLYETHYLENE BAG. CIRCUIT CARDCONDUCTIVE POLYETHYLENE BAG AT T E N T I O N Contents Static Sensitive Handling Precautions Required
NEAX2000 IVS2 Remote PIM System ManualPage 20 ND-70917 (E), Issue 1.0 CHAPTER 2 INSTALLATION Precautions CAU TIO N You must hold the edge of a circuit card when plugging or unplugging the circuit card. If you touch another area, you may be exposed to hazardous voltages. CARD FRONT NEVER TOUCH THE COMPONENTS OR SOLDERED SURFACE WITH BARE HANDS. PBX
CHAPTER 2 INSTALLATION Installation Procedure NEAX2000 IVS2 Remote PIM System Manual ND-70917 (E), Issue 1.0 Page 21 INSTALLATION PROCEDURE Install the Remote PIM System according to the following procedure. Installation Procedure for Main Site Figure 2-2 shows a flowchart of the installation procedure for the Main Site. Figure 2-2 Installation Procedure for Main Site DAI Connection at Main Site BUS Cable Connection START NOTE 1:This procedure is required even if the Main Site is 1-PIM/2-PIM configuration. NOTE 2:This procedure is required when providing PN-M10 card to connect an optical interface. Mounting FP Card Mounting M10 Card Optical Cable Connection See Page 23. See Page 23. See Page 23. See Page 24. See Page 51. See Page 47. See Page 23.Mounting DAIA Card for T1 / DAID Card for E1 Mounting DAIC Card for T1 / DAIF Card for E1 END See Page 55. MP ResetNOTE 1 NOTE 2
NEAX2000 IVS2 Remote PIM System ManualPage 22 ND-70917 (E), Issue 1.0 CHAPTER 2 INSTALLATION Installation Procedure Installation Procedure for Remote Site Figure 2-3 shows a flowchart of the installation procedure for the Remote Site. Figure 2-3 Installation Procedure for Remote Site END START Providing PFT MP ResetSee Page 31. See Page 29. See Page 29. See Page 39. See Page 50. See Page 55. Mounting M10 CardSee Page 29. Mounting Line/Trunk Card for T1 NOTE 1:This procedure is required when providing PN-M10 card to connect an optical interface. NOTE 2:It is recommended that the Power Failure Transfer (PFT) is provided on the Remote Site in case the link between the Main Site and the Remote Site is lost. Mounting DAIB Card for T1 / DAIE Card for E1 Mounting DAIC Card for T1 / DAIF Card for E1 See Page 35. Mounting Line/Trunk Card for E1 Optical Cable ConnectionSee Page 51. DAI Connection at Remote Site NOTE 1 NOTE 2