NEC Neax 2000 Ivs2 Remote Pim System Manual
Have a look at the manual NEC Neax 2000 Ivs2 Remote Pim System Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 1168 NEC manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
NEAX2000 IVS2 Remote PIM System Manual ND-70917 (E), Issue 1.0 Page 3 CHAPTER 1 GENERAL INFORMATION This chapter explains the outline of system configuration, required equipment, system capacity, system conditions, and time slot alloca- tion.
NEAX2000 IVS2 Remote PIM System ManualPage 4 ND-70917 (E), Issue 1.0 CHAPTER 1 GENERAL INFORMATION System Outline SYSTEM OUTLINE Remote PIMs can be installed separately at the distance in one building, or between the offices via the Public Switching Telephone Network (PSTN). The customers in the Remote Site can use the same service features as in the Main Site. Remote PIMs are connected to the Main Site by T1 (1.5 Mbps) / E1 (2 Mbps) digital interface. Figure 1-1 Outline of Remote PIM System PIM 1 .5 M ( T 1 ) / 2 M ( E 1) (MAIN SITE)OFFICE A PIM OFFICE D (REMOTE SITE) PIM OFFICE B (REMOTE SITE) PIM OFFICE C (REMOTE SITE) 1 . 5 M ( T1 ) / 2 M ( E1 ) 1 .5 M (T 1 ) / 2 M (E 1 )
CHAPTER 1 GENERAL INFORMATION PIM Configuration NEAX2000 IVS2 Remote PIM System Manual ND-70917 (E), Issue 1.0 Page 5 PIM CONFIGURATION One PIM can be installed respectively as a Remote Site. A maximum of three Remote Sites can be provided. The number of Remote Sites determines the number of PIMs in one system. Table 1-1 shows the available PIM configuration for the Remote PIM System. Table 1-1 PIM Configuration NUMBER OF PIM AT MAIN SITE AVAILABLE NUMBER OF REMOTE SITE 1 PIM (1 FP)123 2 PIM (1 FP)123 3 PIM (2 FP)12 – 4 PIM (2 FP)12 – 5 PIM (3 FP)1–– 6 PIM (3 FP)1–– 7 PIM (4 FP)––– 8 PIM (4 FP)–––
NEAX2000 IVS2 Remote PIM System ManualPage 6 ND-70917 (E), Issue 1.0 CHAPTER 1 GENERAL INFORMATION System Configuration SYSTEM CONFIGURATION System Configuration for T1 Figure 1-2 shows the system configuration for T1. Figure 1-2 System Configuration for T1 MPRemote PIM1 Remote PIM2 Remote PIM3Remote Site Main Site 23 B Channel 1 D Channel 24 B Channel 24 B Channel 23 B Channel 1 D Channel 24 B Channel 24 B Channel 23 B Channel 1 D Channel 24 B Channel 24 B Channel DAIA 1 (FP1)DAIB (FP1)Line/TRK DAIC 1 DAIC 2 DAIC 1 DAIC 2 DAIA 2 (FP1) DAIC 3 DAIC 4 DAIB (FP2)Line/TRK DAIC 3 DAIC 4 DAIB (FP3)Line/TRK DAIC 5 DAIC 6 DAIA 3 (FP1) DAIC 5 DAIC 6 FP0 TDSW
CHAPTER 1 GENERAL INFORMATION System Configuration NEAX2000 IVS2 Remote PIM System Manual ND-70917 (E), Issue 1.0 Page 7 System Configuration for E1 Figure 1-3 shows the system configuration for E1. Figure 1-3 System Configuration for E1 MPRemote PIM1 Remote PIM2 Remote PIM3Remote Site Main Site 30 B Channel 1 D Channel 30 B Channel 30 B Channel 1 D Channel 30 B Channel 30 B Channel 1 D Channel 30 B Channel DAID 1 (FP1)DAIE (FP1)Line/TRK DAIF 1DAIF 1 DAID 2 (FP2) DAIF 2 DAIE (FP2)Line/TRK DAIF 2 DAIE (FP3)Line/TRK DAIF 3 DAID 3 (FP3) DAIF 3 FP0 TDSW
NEAX2000 IVS2 Remote PIM System ManualPage 8 ND-70917 (E), Issue 1.0 CHAPTER 1 GENERAL INFORMATION Required Equipment REQUIRED EQUIPMENT Table 1-2 shows the required equipment for providing the Remote PIM System. Table 1-2 Required Equipmen t EQUIPMENT NAMEFUNCTIONAL NAMEFUNCTION PN-DAIA DAI T1 Digital Trunk Interface (23B + D, 1.5 Mbps) Card for Remote PIM Accommodates 24-channel PCM digital lines, and provides Firmware Processor and BUS interface One through three cards must be provided at the Main Site, which corresponds to the number of the Remote Site. PN-DAIB DAI T1 Digital Trunk Interface (23B + D, 1.5 Mbps) Card for Remote PIM Accommodates 24-channel PCM digital lines, and provides Firmware Processor One card is required per Remote PIM at the Remote Site. PN-DAIC DAI T1 Digital Trunk Interface (23B + D, 1.5 Mbps) Channel Expansion Card Accommodates 24-channel PCM digital lines One through six cards can be provided at the Main Site. Two cards can be provided at the Remote Site. PN-DAID DAI E1 Digital Trunk Interface (2 Mbps) Card for Remote PIM Accommodates 30-channel PCM digital lines and provides Firmware Processor and BUS interface One though three cards must be provided at the Main Site, which corresponds to the number of the Remote Site. PN-DAIE DAI E1 Digital Trunk Interface (2 Mbps) Card for Remote PIM Accommodates 30-channel PCM digital lines and provides Firmware Processor One card is required per Remote PIM at the Remote Site. PN-DAIF DAI E1 Digital Trunk Interface (2 Mbps) Channel Expansion Card Accommodates 30-channel PCM digital lines One through three cards can be provided at the Main Site. One card can be provided at the Remote Site.
CHAPTER 1 GENERAL INFORMATION Required Equipment NEAX2000 IVS2 Remote PIM System Manual ND-70917 (E), Issue 1.0 Page 9 PN-CP15 FP Firmware Processor Card Provides Line/Trunk interface, Memory (RAM 768 KB), and inter-module BUS interface. BUS interface functions as a driver/receiver of various signals, adjusts gate delay timing and cable delay timing, monitors I/O BUS and PCM BUS. When the system consists of three or more PIMs, one each of this card is mounted respectively in PIM0, PIM2, PIM4, and PIM6. For Remote PIM System, the FP card must be mounted on PIM0 at the Main Site, even if the system is 1-PIM/2-PIM configuration. PN-M10 M10 Optical Interface Card Provides internal optical modem to T1/E1 network or Remote PIM Line length : 10 km (6.25 miles) or less Line coding: CMI RMT BUS CA-A– 0.6 m (2 ft.) PCM Signal Cable Used for connecting between the DAIA/DAID card and the BUS connector on the PIM BWB 17-TW-0.3 CONN CA-A– 0.3 m (1 ft.) Connection Cable Between the DAIA/DAID cards Required when multiple DAIA/DAID cards are mounted in a PIM at the Main Site 48-TW-0.2 CONN CA– 0.2 m (0.7 ft.) Connection Cable Used for the following connection between the cards: •DAIA-DAIC DAIB-DAIC DAIC-DAIC DAID-DAIF DAIE-DAIF Table 1-2 Required Equipment (Continued) EQUIPMENT NAMEFUNCTIONAL NAMEFUNCTION
NEAX2000 IVS2 Remote PIM System ManualPage 10 ND-70917 (E), Issue 1.0 CHAPTER 1 GENERAL INFORMATION System Capacity SYSTEM CAPACITY System Capacity for T1 Table 1-3 shows the system capacity for T1. NOTE 1:One port is used for the control signaling channel. NOTE 2:When the Main Site consists of 7 or 8 PIMs, Remote PIM cannot be provided. Table 1-3 System Capacity for T1 DESCRIPTIONCAPACITY REMARKS MAIN PIM REMOTE PIM DAIA card 3 – DAIB card – 1 DAIC card 6 2 Line/Trunk Ports on Remote Site–24 NOTE 1Main PIM : 1 DAIA Remote PIM: 1 DAIB 48 NOTE 1Main PIM : 1 DAIA, 1 DAIC Remote PIM: 1 DAIB, 1 DAIC 64 NOTE 1Main PIM : 1 DAIA, 2 DAIC Remote PIM: 1 DAIB, 2 DAIC Number of PIM 1/2 3 Number of PIM depends on the number of Main PIM and Remote PIM. See PIM Configuration on Pag e 5. 3/4 2 5/6 1 7/8 0 NOTE 2
CHAPTER 1 GENERAL INFORMATION System Capacity NEAX2000 IVS2 Remote PIM System Manual ND-70917 (E), Issue 1.0 Page 11 System Capacity for E1 Table 1-4 shows the system capacity for E1. NOTE:When the Main Site consists of 7 or 8 PIMs, Remote PIM cannot be provided. Table 1-4 System Capacity for E1 DESCRIPTIONCAPACITY REMARKS MAIN PIM REMOTE PIM DAID card 3 – DAIE card – 1 DAIF card 3 1 Line/Trunk Ports on Remote Site– 30 Main PIM : 1 DAID Remote PIM: 1 DAIE 60 Main PIM : 1 DAID, 1 DAIF Remote PIM: 1 DAIE, 1 DAIF Number of PIM 1/2 3 Number of PIM depends on the number of Main PIM and Remote PIM. See PIM Configuration on Pag e 5. 3/4 2 5/6 1 7/8 0 NOTE
NEAX2000 IVS2 Remote PIM System ManualPage 12 ND-70917 (E), Issue 1.0 CHAPTER 1 GENERAL INFORMATION System Conditions SYSTEM CONDITIONS Only one PIM configuration is available at the Remote Site. Remote PIM can be installed at a maximum of 400 m (1312 ft.) distance from the Main Site. Using the Optical Interface card (PN-M10) or line extension equipment (Repeater, MUX, etc.), the distance can be extended. At the Remote Site, the line/trunk cards can be used as same as the Main Site. For North America, the line/trunk cards, except the CSI card for wireless system according to UTAM regulation, can be used. The application processor cards cannot be used at the Remote Site. When you provide the ILC or CSI card to the Remote Site, the ICH or CSH card must be installed on the Main Site. For Remote PIM System, the installation procedures for modules, circuit cards, and periph- eral equipment are the same as those for the regular system, except the DAI cards instal- lation and the BUS cable connection. Refer to the Installation Procedure Manual for detailed information. When the link between the Main Site and Remote Site has been lost due to power failure or PCM Frame Loss, the system activates the Power Failure Transfer (PFT) automatically on the Remote Site, if provided. The Resident System Programming cannot be set to the Remote Site while the Main Site can be set. If ILC or COTB card is mounted in Remote PIM, the T1 link between main and Remote Sites must be configured as 64 Kbps with ESF and B8ZS.