    ND-70917 (E), Issue 1.0   Page 3
    CHAPTER 1
    GENERAL INFORMATION
    This chapter explains the outline of system configuration, required
    equipment, system capacity, system conditions, and time slot alloca-
    tion. 
    						
    							 NEAX2000 IVS2 Remote PIM System ManualPage 4  ND-70917 (E), Issue 1.0
    CHAPTER 1  GENERAL INFORMATION
    System Outline
    SYSTEM OUTLINE
    Remote PIMs can be installed separately at the distance in one building, or between the offices
    via the Public Switching Telephone Network (PSTN).
    The customers in the Remote Site can use the same service features as in the Main Site.
    Remote PIMs are connected to the Main Site by T1 (1.5 Mbps) / E1 (2 Mbps) digital interface.
    Figure 1-1  Outline of Remote PIM System
    PIM
    1
    .5
     M
     (
    T
    1
    )
     /
     2
     M
     (
    E
    1)
    (MAIN SITE)OFFICE A
    PIM
    OFFICE D
    (REMOTE SITE)
    PIM
    OFFICE B
    (REMOTE SITE)
    PIM
    OFFICE C
    (REMOTE SITE)
    1
    .
    5 
    M
     
    (
    T1
    )
     
    /
     
    2 
    M
     
    (
    E1
    )
    1
    .5
     M
     (T
    1
    ) / 2
     
    M
     (E
    1
    ) 
    						
    							CHAPTER 1  GENERAL INFORMATION
    PIM Configuration
    NEAX2000 IVS2 Remote PIM System Manual    
    ND-70917 (E), Issue 1.0   Page 5
    PIM CONFIGURATION
    One PIM can be installed respectively as a Remote Site. A maximum of three Remote Sites can
    be provided. The number of Remote Sites determines the number of PIMs in one system.
    Table 1-1 shows the available PIM configuration for the Remote PIM System.
    Table 1-1  PIM Configuration
    NUMBER OF PIM AT MAIN SITE AVAILABLE NUMBER OF REMOTE SITE
    1 PIM
    (1 FP)123
    2 PIM
    (1 FP)123
    3 PIM
    (2 FP)12 –
    4 PIM
    (2 FP)12 –
    5 PIM
    (3 FP)1––
    6 PIM
    (3 FP)1––
    7 PIM
    (4 FP)–––
    8 PIM
    (4 FP)––– 
    						
    							 NEAX2000 IVS2 Remote PIM System ManualPage 6  ND-70917 (E), Issue 1.0
    CHAPTER 1  GENERAL INFORMATION
    System Configuration
    SYSTEM CONFIGURATION
    System Configuration for T1
    Figure 1-2 shows the system configuration for T1. 
    Figure 1-2  System Configuration for T1
    MPRemote PIM1
    Remote PIM2
    Remote PIM3Remote Site Main Site
    23 B Channel
    1 D Channel
    24 B Channel
    24 B Channel
    23 B Channel
    1 D Channel
    24 B Channel
    24 B Channel
    23 B Channel
    1 D Channel
    24 B Channel
    24 B Channel
    DAIA 1 
    (FP1)DAIB 
    (FP1)Line/TRK
    DAIC 1
    DAIC 2
    DAIC 1
    DAIC 2
    DAIA 2 
    (FP1)
    DAIC 3
    DAIC 4
    DAIB 
    (FP2)Line/TRK
    DAIC 3
    DAIC 4
    DAIB 
    (FP3)Line/TRK
    DAIC 5
    DAIC 6
    DAIA 3 
    (FP1)
    DAIC 5
    DAIC 6
    FP0
    TDSW 
    						
    							CHAPTER 1  GENERAL INFORMATION
    System Configuration
    NEAX2000 IVS2 Remote PIM System Manual    
    ND-70917 (E), Issue 1.0   Page 7
    System Configuration for E1
    Figure 1-3 shows the system configuration for E1.
    Figure 1-3  System Configuration for E1
    MPRemote PIM1
    Remote PIM2
    Remote PIM3Remote Site Main Site
    30 B Channel
    1 D Channel
    30 B Channel
    30 B Channel
    1 D Channel
    30 B Channel
    30 B Channel
    1 D Channel
    30 B Channel
    DAID 1 
    (FP1)DAIE 
    (FP1)Line/TRK
    DAIF 1DAIF 1
    DAID 2 
    (FP2)
    DAIF 2
    DAIE 
    (FP2)Line/TRK
    DAIF 2
    DAIE 
    (FP3)Line/TRK
    DAIF 3
    DAID 3 
    (FP3)
    DAIF 3
    FP0
    TDSW 
    						
    							 NEAX2000 IVS2 Remote PIM System ManualPage 8  ND-70917 (E), Issue 1.0
    CHAPTER 1  GENERAL INFORMATION
    Required Equipment
    REQUIRED EQUIPMENT
    Table 1-2 shows the required equipment for providing the Remote PIM System.
    Table 1-2  Required Equipmen t
    EQUIPMENT 
    NAMEFUNCTIONAL
    NAMEFUNCTION
    PN-DAIA DAI T1 Digital Trunk Interface (23B + D, 1.5 Mbps) Card for 
    Remote PIM
    Accommodates 24-channel PCM digital lines, and provides 
    Firmware Processor and BUS interface
    One through three cards must be provided at the Main Site,
    which corresponds to the number of the Remote Site.
    PN-DAIB DAI T1 Digital Trunk Interface (23B + D, 1.5 Mbps) Card for 
    Remote PIM
    Accommodates 24-channel PCM digital lines, and provides 
    Firmware Processor
    One card is required per Remote PIM at the Remote Site.
    PN-DAIC DAI T1 Digital Trunk Interface (23B + D, 1.5 Mbps) Channel 
    Expansion Card 
    Accommodates 24-channel PCM digital lines
    One through six cards can be provided at the Main Site.
    Two cards can be provided at the Remote Site.
    PN-DAID DAI E1 Digital Trunk Interface (2 Mbps) Card for Remote PIM 
    Accommodates 30-channel PCM digital lines and provides 
    Firmware Processor and BUS interface
    One though three cards must be provided at the Main Site, 
    which corresponds to the number of the Remote Site.
    PN-DAIE DAI E1 Digital Trunk Interface (2 Mbps) Card for Remote PIM 
    Accommodates 30-channel PCM digital lines and provides 
    Firmware Processor
    One card is required per Remote PIM at the Remote Site.
    PN-DAIF DAI E1 Digital Trunk Interface (2 Mbps) Channel Expansion Card 
    Accommodates 30-channel PCM digital lines
    One through three cards can be provided at the Main Site.
    One card can be provided at the Remote Site. 
    						
    							CHAPTER 1  GENERAL INFORMATION
    Required Equipment
    NEAX2000 IVS2 Remote PIM System Manual    
    ND-70917 (E), Issue 1.0   Page 9
    PN-CP15 FP Firmware Processor Card
    Provides Line/Trunk interface, Memory (RAM 768 KB), and 
    inter-module BUS interface. BUS interface functions as a 
    driver/receiver of various signals, adjusts gate delay timing 
    and cable delay timing, monitors I/O BUS and PCM BUS. 
    When the system consists of three or more PIMs, one each of 
    this card is mounted respectively in PIM0, PIM2, PIM4, and 
    PIM6.
    For Remote PIM System, the FP card must be mounted on 
    PIM0 at the Main Site, even if the system is 1-PIM/2-PIM 
    configuration.
    PN-M10 M10 Optical Interface Card
    Provides internal optical modem to T1/E1 network or Remote 
    PIM
    Line length : 10 km (6.25 miles) or less
    Line coding: CMI
    RMT BUS 
    CA-A– 0.6 m (2 ft.) PCM Signal Cable
    Used for connecting between the DAIA/DAID card and the 
    BUS connector on the PIM BWB
    17-TW-0.3
    CONN CA-A– 0.3 m (1 ft.) Connection Cable Between the DAIA/DAID cards
    Required when multiple DAIA/DAID cards are mounted in a 
    PIM at the Main Site
    48-TW-0.2
    CONN CA– 0.2 m (0.7 ft.) Connection Cable
    Used for the following connection between the cards:
    •DAIA-DAIC
    DAIB-DAIC
    DAIC-DAIC
    DAID-DAIF
    DAIE-DAIF
    Table 1-2  Required Equipment (Continued)
    EQUIPMENT 
    NAMEFUNCTIONAL
    NAMEFUNCTION 
    						
    							 NEAX2000 IVS2 Remote PIM System ManualPage 10  ND-70917 (E), Issue 1.0
    CHAPTER 1  GENERAL INFORMATION
    System Capacity
    SYSTEM CAPACITY
    System Capacity for T1
    Table 1-3 shows the system capacity for T1. 
    NOTE 1:One port is used for the control signaling channel.
    NOTE 2:When the Main Site consists of 7 or 8 PIMs, Remote PIM cannot be provided.
    Table 1-3  System Capacity for T1
    DESCRIPTIONCAPACITY
    REMARKS
    MAIN PIM REMOTE PIM
    DAIA card 3 –
    DAIB card – 1
    DAIC card 6 2
    Line/Trunk Ports 
    on Remote Site–24 
    NOTE 1Main PIM : 1 DAIA
    Remote PIM: 1 DAIB
    48 
    NOTE 1Main PIM : 1 DAIA, 1 DAIC
    Remote PIM: 1 DAIB, 1 DAIC
    64 
    NOTE 1Main PIM : 1 DAIA, 2 DAIC
    Remote PIM: 1 DAIB, 2 DAIC
    Number of PIM 1/2 3 Number of PIM depends on 
    the number of Main PIM and 
    Remote PIM. 
    See PIM Configuration on 
    Pag e 5. 3/4 2
    5/6 1
    7/8 0 
    NOTE 2 
    						
    							CHAPTER 1  GENERAL INFORMATION
    System Capacity
    NEAX2000 IVS2 Remote PIM System Manual    
    ND-70917 (E), Issue 1.0   Page 11
    System Capacity for E1
    Table 1-4 shows the system capacity for E1.
    NOTE:When the Main Site consists of 7 or 8 PIMs, Remote PIM cannot be provided.
    Table 1-4  System Capacity for E1
    DESCRIPTIONCAPACITY
    REMARKS
    MAIN PIM REMOTE PIM
    DAID card 3 –
    DAIE card – 1
    DAIF card 3 1
    Line/Trunk Ports 
    on Remote Site– 30 Main PIM : 1 DAID
    Remote PIM: 1 DAIE
    60 Main PIM : 1 DAID, 1 DAIF
    Remote PIM: 1 DAIE, 1 DAIF
    Number of PIM 1/2 3 Number of PIM depends on 
    the number of Main PIM and 
    Remote PIM. 
    See PIM Configuration on 
    Pag e 5. 3/4 2
    5/6 1
    7/8 0 
    NOTE 
    						
    							 NEAX2000 IVS2 Remote PIM System ManualPage 12  ND-70917 (E), Issue 1.0
    CHAPTER 1  GENERAL INFORMATION
    System Conditions
    SYSTEM CONDITIONS
     Only one PIM configuration is available at the Remote Site.
     Remote PIM can be installed at a maximum of 400 m (1312 ft.) distance from the Main Site.
    Using the Optical Interface card (PN-M10) or line extension equipment (Repeater, MUX, 
    etc.), the distance can be extended.
     At the Remote Site, the line/trunk cards can be used as same as the Main Site. 
    For North America, the line/trunk cards, except the CSI card for wireless system according 
    to UTAM regulation, can be used.
     The application processor cards cannot be used at the Remote Site. When you provide the 
    ILC or CSI card to the Remote Site, the ICH or CSH card must be installed on the Main Site. 
     For Remote PIM System, the installation procedures for modules, circuit cards, and periph-
    eral equipment are the same as those for the regular system, except the DAI cards instal-
    lation and the BUS cable connection.
    Refer to the Installation Procedure Manual for detailed information.
     When the link between the Main Site and Remote Site has been lost due to power failure or 
    PCM Frame Loss, the system activates the Power Failure Transfer (PFT) automatically on 
    the Remote Site, if provided.
     The Resident System Programming cannot be set to the Remote Site while the Main Site 
    can be set.
     If ILC or COTB card is mounted in Remote PIM, the T1 link between main and Remote Sites 
    must be configured as 64 Kbps with ESF and B8ZS. 
    						