CHAPTER 3 TROUBLESHOOTING NEAX2000 IVS2 Remote PIM System Manual ND-70917 (E), Issue 1.0 Page 63 PN-DAIF (DAIF)RUN lamp is not flashing.Abnormal operation of DAIF card1 Reset the MB switch. (Down→Up→Down) 2 If the fault cannot be cleared, replace the card. LINK lamp is not on. Layer 2 link connec- tion failure between DAID and DAIE1 Check to see if the cable between DAID and DAIE is correctly connected. Refer to Connection Between Main Site and Remote Site on Page 47. 2 Reset the MB...
Page 72
NEAX2000 IVS2 Remote PIM System ManualPage 64 ND-70917 (E), Issue 1.0 CHAPTER 3 TROUBLESHOOTING PN-M10 (M10) CK0 lamp is not on. Cable connection failure between Digi- tal Trunk Interface and No. 0 circuit of M101 Check to see if the cable between Digital Trunk Inter- face and M10 is correctly connected. 2 Check the switch setting of M10. 3 If the fault cannot be cleared, replace the card. CK1 lamp is not on. Cable connection failure between Digi- tal Trunk Interface and No. 1 circuit of...
Page 73
NEAX2000 IVS2 Remote PIM System Manual ND-70917 (E), Issue 1.0 Page 65 CHAPTER 4 CIRCUIT CARD INFORMATION This chapter explains the mounting location, the meaning of lamp in- dications, and the method of switch settings of each circuit card for the Remote PIM.
Page 74
NEAX2000 IVS2 Remote PIM System ManualPage 66 ND-70917 (E), Issue 1.0 CHAPTER 4 CIRCUIT CARD INFORMATION How to Read This Chapter HOW TO READ THIS CHAPTER This chapter explains each circuit card used in this system. Explanations are given in alphabeti- cal order of the circuit card names within each circuit card category (Control, Application Proces- sor, and Line/Trunk). (1) Locations of Lamps, Switches, and Connectors The locations of lamps, switches, and connectors of each circuit card are shown by...
Page 75
CHAPTER 4 CIRCUIT CARD INFORMATION Mounting Location of Circuit Card NEAX2000 IVS2 Remote PIM System Manual ND-70917 (E), Issue 1.0 Page 67 MOUNTING LOCATION OF CIRCUIT CARD This section explains the conditions for mounting circuit cards for the Remote PIM. Figure 4-1 shows circuit card mounting slots allocated in the PIM. Figure 4-1 Mounting Location of Circuit Card *1PN-CP15 card must be mounted in FP11 slot on Main Site PIM0 for Remote PIM system. *2PN-CP15 card in FP12 slot on Main Site PIM2,...
Page 76
NEAX2000 IVS2 Remote PIM System ManualPage 68 ND-70917 (E), Issue 1.0 CHAPTER 4 CIRCUIT CARD INFORMATION List of Required Cards LIST OF REQUIRED CARDS Table 4-1 shows the required cards that are explained in this section. *MB = Make Busy Table 4-1 List of Required Cards NAME (FUNCTIONAL NAME)LAMP X: PROVIDED –: NOT PROVIDEDSWITCH X: PROVIDED –: NOT PROVIDEDEXTRACTION/ INSERTION WITH POWER ON X: ALLOWED : ALLOWED AFTER MB* –: NOT ALLOWEDREFERENCE PA G E PN-CP15 (FP) X XPage 69 PN-DAIA (DAI) X...
Page 77
CHAPTER 4 CIRCUIT CARD INFORMATION PN-CP15 (FP) NEAX2000 IVS2 Remote PIM System Manual ND-70917 (E), Issue 1.0 Page 69 PN-CP15 (FP) Locations of Lamps, Switches, and Connectors Lamp Indications LAMP NAMECOLOR FUNCTION RUN Green Flashes at 120 IPM while the circuit card is operating normally SENSE RU N MB SW1
Page 78
NEAX2000 IVS2 Remote PIM System ManualPage 70 ND-70917 (E), Issue 1.0 CHAPTER 4 CIRCUIT CARD INFORMATION PN-CP15 (FP) Switch Settings The figure in the SWITCH NAME column and the position in in the SETTING POSITION column indicate the standard setting of the switch. When the switch is not set as shown by the figure and , the setting of the switch varies with the system concerned. NOTE 1:Set the groove on the switch to the desired position. NOTE 2:When the power is on, flip the MB switch to ON...
Page 79
CHAPTER 4 CIRCUIT CARD INFORMATION PN-DAIA (DAI) NEAX2000 IVS2 Remote PIM System Manual ND-70917 (E), Issue 1.0 Page 71 PN-DAIA (DAI) Location of Lamps, Switches, and Connectors Lamp Indications LAMP NAMECOLOR FUNCTION RUN Green Flashes at 120 IPM while this card is operating normally LINK Green Remains lit when a link between this card and a distant office is normally connected Goes out after 15 seconds of link disconnection RED Red Remains lit when detecting PCM signal loss or Frame Alignment...
Page 80
NEAX2000 IVS2 Remote PIM System ManualPage 72 ND-70917 (E), Issue 1.0 CHAPTER 4 CIRCUIT CARD INFORMATION PN-DAIA (DAI) Switch Settings SWITCH NAMESWITCH NUMBERSETTING POSITIONFUNCTION CHECK SENSE (Rotary SW) NOTE 10-FFP (Firmware Processor) Number setting for the DA I A c a rd By this setting, the system regards the DAIA card and the opposite DAIB card as one Firmware Pro- cessor 0 Not used 1FP No. 1 2FP No. 2 3FP No. 3 4 – F Not used MB (Toggle SW) NOTE 2 UP For make-busy For normal operation SW1...