Page 71

CHAPTER 3  TROUBLESHOOTING
NEAX2000 IVS2 Remote PIM System Manual    
ND-70917 (E), Issue 1.0   Page 63
PN-DAIF 
(DAIF)RUN lamp is not 
flashing.Abnormal operation 
of DAIF card1 Reset the MB switch.
(Down→Up→Down)
2 If the fault cannot be 
cleared, replace the card.
LINK lamp is not on. Layer 2 link connec-
tion failure between 
DAID and DAIE1 Check to see if the cable 
between DAID and DAIE is 
correctly connected. Refer 
to Connection Between 
Main Site and Remote Site 
on Page 47.
2 Reset the MB...

Page 72

 NEAX2000 IVS2 Remote PIM System ManualPage 64  ND-70917 (E), Issue 1.0
CHAPTER 3  TROUBLESHOOTING
PN-M10 (M10) CK0 lamp is not on. Cable connection 
failure between Digi-
tal Trunk Interface 
and No. 0 circuit of 
M101 Check to see if the cable 
between Digital Trunk Inter-
face and M10 is correctly 
connected.
2 Check the switch setting of 
M10.
3 If the fault cannot be 
cleared, replace the card.
CK1 lamp is not on. Cable connection 
failure between Digi-
tal Trunk Interface 
and No. 1 circuit of...

Page 73

NEAX2000 IVS2 Remote PIM System Manual    
ND-70917 (E), Issue 1.0   Page 65
CHAPTER 4
CIRCUIT CARD 
INFORMATION
This chapter explains the mounting location, the meaning of lamp in-
dications, and the method of switch settings of each circuit card for the
Remote PIM. 

Page 74

 NEAX2000 IVS2 Remote PIM System ManualPage 66  ND-70917 (E), Issue 1.0
CHAPTER 4  CIRCUIT CARD INFORMATION
How to Read This Chapter
HOW TO READ THIS CHAPTER
This chapter explains each circuit card used in this system. Explanations are given in alphabeti-
cal order of the circuit card names within each circuit card category (Control, Application Proces-
sor, and Line/Trunk).
(1) Locations of Lamps, Switches, and Connectors
The locations of lamps, switches, and connectors of each circuit card are shown by...

Page 75

CHAPTER 4  CIRCUIT CARD INFORMATION
Mounting Location of Circuit Card
NEAX2000 IVS2 Remote PIM System Manual    
ND-70917 (E), Issue 1.0   Page 67
MOUNTING LOCATION OF CIRCUIT CARD
This section explains the conditions for mounting circuit cards for the Remote PIM.
Figure 4-1 shows circuit card mounting slots allocated in the PIM.
Figure 4-1  Mounting Location of Circuit Card
*1PN-CP15 card must be mounted in FP11 slot on Main Site PIM0 for Remote PIM system.
*2PN-CP15 card in FP12 slot on Main Site PIM2,...

Page 76

 NEAX2000 IVS2 Remote PIM System ManualPage 68  ND-70917 (E), Issue 1.0
CHAPTER 4  CIRCUIT CARD INFORMATION
List of Required Cards
LIST OF REQUIRED CARDS
Table 4-1 shows the required cards that are explained in this section.
*MB = Make Busy
Table 4-1  List of Required Cards
NAME
(FUNCTIONAL
NAME)LAMP
X: PROVIDED
–: NOT 
PROVIDEDSWITCH
X: PROVIDED
–: NOT 
PROVIDEDEXTRACTION/
INSERTION WITH 
POWER ON
X: ALLOWED
: ALLOWED 
AFTER MB*
–: NOT ALLOWEDREFERENCE
PA G E
PN-CP15 (FP) X XPage 69
PN-DAIA (DAI) X...

Page 77

CHAPTER 4  CIRCUIT CARD INFORMATION
PN-CP15 (FP)
NEAX2000 IVS2 Remote PIM System Manual    
ND-70917 (E), Issue 1.0   Page 69
PN-CP15 (FP)
Locations of Lamps, Switches, and Connectors
Lamp Indications
LAMP 
NAMECOLOR FUNCTION
RUN Green Flashes at 120 IPM while the circuit card is operating normally
SENSE
RU N
MB
SW1 

Page 78

 NEAX2000 IVS2 Remote PIM System ManualPage 70  ND-70917 (E), Issue 1.0
CHAPTER 4  CIRCUIT CARD INFORMATION
PN-CP15 (FP)
Switch Settings
The figure in the SWITCH NAME column and the position in    in the SETTING POSITION
column indicate the standard setting of the switch. When the switch is not set as shown by the
figure and    , the setting of the switch varies with the system concerned.
NOTE 1:Set the groove on the switch to the desired position.
NOTE 2:When the power is on, flip the MB switch to ON...

Page 79

CHAPTER 4  CIRCUIT CARD INFORMATION
PN-DAIA (DAI)
NEAX2000 IVS2 Remote PIM System Manual    
ND-70917 (E), Issue 1.0   Page 71
PN-DAIA (DAI)
Location of Lamps, Switches, and Connectors
Lamp Indications
LAMP 
NAMECOLOR FUNCTION
RUN Green Flashes at 120 IPM while this card is operating normally
LINK Green Remains lit when a link between this card and a distant office is 
normally connected
Goes out after 15 seconds of link disconnection
RED Red Remains lit when detecting PCM signal loss or Frame Alignment...

Page 80

 NEAX2000 IVS2 Remote PIM System ManualPage 72  ND-70917 (E), Issue 1.0
CHAPTER 4  CIRCUIT CARD INFORMATION
PN-DAIA (DAI)
Switch Settings
SWITCH NAMESWITCH 
NUMBERSETTING 
POSITIONFUNCTION CHECK
SENSE
(Rotary SW)
NOTE 10-FFP (Firmware Processor) Number setting for the
DA I A c a rd
By this setting, the system regards the DAIA card
and the opposite DAIB card as one Firmware Pro-
cessor
0 Not used
1FP No. 1
2FP No. 2
3FP No. 3
4 – F Not used
MB (Toggle SW)
NOTE 2
UP For make-busy
For normal operation
SW1...