CHAPTER 2  INSTALLATION
Installation for Main Site
NEAX2000 IVS2 Remote PIM System Manual    
ND-70917 (E), Issue 1.0   Page 23
INSTALLATION FOR MAIN SITE
Mounting DAIA Card for T1 / DAID Card for E1
(1) Before mounting the DAIA/DAID card, set the MB switch to UP position, 
and set the other switches to appropriate position. See CHAPTER 4.
(2) Mount the DAIA/DAID card in the AP slots (AP00-AP11) on the Main Site PIM0, 2, 4.
A maximum of three DAIA/DAID cards can be mounted.
After mounting the card, set...

Page 32

 NEAX2000 IVS2 Remote PIM System ManualPage 24  ND-70917 (E), Issue 1.0
CHAPTER 2  INSTALLATION
Installation for Main Site
BUS Cable Connection
(1) Cable Connection Between BUS Connector on the BWB and DAIA/DAID Card
Connect the DAIA/DAID card to the BUS connector on the BWB by the RMT BUS CA-A, as 
shown in Figure 2-4.
In BUS connector on the BWB, BUS1B or BUS0B of the even-numbered PIMs (PIM0, 2, 4, 
etc.) must be used for this connection.
Figure 2-4  BUS Cable Connection (1 of 2)
(a) When mounting...

Page 33

CHAPTER 2  INSTALLATION
Installation for Main Site
NEAX2000 IVS2 Remote PIM System Manual    
ND-70917 (E), Issue 1.0   Page 25
Figure 2-4  BUS Cable Connection (2 of 2)
(b) When mounting DAIA/DAID card on PIM2, PIM4
When Main PIM is 5 or 6 PIM configuration, the DAIA/DAID card must be mounted 
on PIM2 and/or PIM4, and connected as follows:
RMT BUS CA-A
5 PIM
6 PIM
NOTE:DAIA/DAID card must be mounted in even-numbered PIMs. When mounted in
PIM0 BWB BUS connector, BUS1B or BUS0B may be used for this...

Page 34

 NEAX2000 IVS2 Remote PIM System ManualPage 26  ND-70917 (E), Issue 1.0
CHAPTER 2  INSTALLATION
Installation for Main Site
(2) Cable Connection Between DAIA/DAID Cards
If two or three DAIA/DAID cards are mounted on one PIM, connect between the PCM0 
connector and PCM1 connector on the DAIA/DAID cards by 17-TW-0.3 CONN CA-A, as 
shown in Figure 2-5.
Up to three DAIA/DAID cards can be connected directly by a daisy chain connection on one 
PIM.
Figure 2-5  DAIA/DAID Between DAIA/DAID Cable Connection...

Page 35

CHAPTER 2  INSTALLATION
Installation for Main Site
NEAX2000 IVS2 Remote PIM System Manual    
ND-70917 (E), Issue 1.0   Page 27
(3) Cable Connection Between DAIA/DAID Card and DAIC/DAIF Card
Connect between the RBUS connector on the DAIC/DAIF card and the BUS connector on 
the DAIA/DAID card by 48-TW-0.2 CONN CA, as shown in Figure 2-6.
Up to two DAIC cards can be mounted per DAIA card.
Only one DAIF card can be mounted per DAID card.
Figure 2-6  DAIA/DAID Between DAIC/DAIF Cable Connection (1 of 2)
:...

Page 36

 NEAX2000 IVS2 Remote PIM System ManualPage 28  ND-70917 (E), Issue 1.0
CHAPTER 2  INSTALLATION
Installation for Main Site
Figure 2-6  DAIA/DAID Between DAIC/DAIF Cable Connection (2 of 2)
: 17-TW-0.3 CONN CA-A
When mounting 3 DAIA/DAID cards and 3 DAIC/DAIF cards
: 48-TW-0.2 CONN CA
BUS
TBUS
RBUS
PCM1
PCM0
DAIC DAIA
/DAIF /DAIDDAIC DAIA
/DAIF /DAIDDAIC DAIA
/DAIF /DAID
When mounting 3 DAIA cards and 6 DAIC cards
BUS
TBUS
RBUS
PCM1
PCM0
DAICDAIA DAICDAIA DAICDAIA 

Page 37

CHAPTER 2  INSTALLATION
Installation for Remote Site
NEAX2000 IVS2 Remote PIM System Manual    
ND-70917 (E), Issue 1.0   Page 29
INSTALLATION FOR REMOTE SITE
Mounting DAIB Card for T1 / DAIE Card for E1
(1) Before mounting the DAIB/DAIE card, set the MB switch to UP position, 
and set the other switches to appropriate position. See CHAPTER 4.
(2) Mount the DAIB/DAIE card in the MP slot on Remote PIM.
After mounting the card, set the MB switch to  DOWN position.
Mounting DAIC Card for T1 / DAIF Card for...

Page 38

 NEAX2000 IVS2 Remote PIM System ManualPage 30  ND-70917 (E), Issue 1.0
CHAPTER 2  INSTALLATION
Installation for Remote Site
BUS Cable Connection
Connect between the BUS connector on the DAIB/DAIE card and the RBUS connector on the
DAIC/DAIF card by the 48-TW-0.2 CONN CA, as shown in Figure 2-7.
Figure 2-7  DAIB/DAIE Between DAIC/DAIF Cable Connection
DAICDAIB
TBUS
RBUSBUS
• When mounting 1 DAIC/DAIF card
DAIC
TBUS
RBUSBUSDAIC
 When mounting 2 DAIC cards
/DAIF/DAIE
DAIB 48-TW-0.2 CONN CA
48-TW-0.2 CONN CA 

Page 39

CHAPTER 2  INSTALLATION
Installation for Remote Site
NEAX2000 IVS2 Remote PIM System Manual    
ND-70917 (E), Issue 1.0   Page 31
Mounting Line/Trunk Card for T1
(1) Mount line/trunk cards in the LT slots on the Remote PIM.
(2) Connect the line cables by referring to Figure 2-8 and Ta b l e  2 - 1.
Figure 2-8  Mounting Location of Line/Trunk Card for T1
Table 2-1  LTC Connector Accommodation for T1
LTC CONNECTOR CARD SLOT NUMBER
LT C 0 LT 0 0 ~ LT 0 2
LT C 1 LT 0 3 ~ LT 0 5
LT C 2 LT 0 6 ~ LT 0 8
LT C 3...

Page 40

 NEAX2000 IVS2 Remote PIM System ManualPage 32  ND-70917 (E), Issue 1.0
CHAPTER 2  INSTALLATION
Installation for Remote Site
Figure 2-9  Location of Each LEN for T1
NOTE 1:A maximum of 63 line/trunks can be accommodated in one Remote PIM.
NOTE 2:In Slot 08-11, only 4-port line/trunk cards are mountable.
When the following 8-port cards are mounted in Slot 04-07, any line/trunk cards
are not mountable in Slot 08-11.
8COT, 8DLC, 8LC, 8RSTA, 4DAT, CFTB, 2CSI, 2ILC  When opposite DAIA card is set to FP No....