CHAPTER 2 INSTALLATION Installation for Main Site NEAX2000 IVS2 Remote PIM System Manual ND-70917 (E), Issue 1.0 Page 23 INSTALLATION FOR MAIN SITE Mounting DAIA Card for T1 / DAID Card for E1 (1) Before mounting the DAIA/DAID card, set the MB switch to UP position, and set the other switches to appropriate position. See CHAPTER 4. (2) Mount the DAIA/DAID card in the AP slots (AP00-AP11) on the Main Site PIM0, 2, 4. A maximum of three DAIA/DAID cards can be mounted. After mounting the card, set...
Page 32
NEAX2000 IVS2 Remote PIM System ManualPage 24 ND-70917 (E), Issue 1.0 CHAPTER 2 INSTALLATION Installation for Main Site BUS Cable Connection (1) Cable Connection Between BUS Connector on the BWB and DAIA/DAID Card Connect the DAIA/DAID card to the BUS connector on the BWB by the RMT BUS CA-A, as shown in Figure 2-4. In BUS connector on the BWB, BUS1B or BUS0B of the even-numbered PIMs (PIM0, 2, 4, etc.) must be used for this connection. Figure 2-4 BUS Cable Connection (1 of 2) (a) When mounting...
Page 33
CHAPTER 2 INSTALLATION Installation for Main Site NEAX2000 IVS2 Remote PIM System Manual ND-70917 (E), Issue 1.0 Page 25 Figure 2-4 BUS Cable Connection (2 of 2) (b) When mounting DAIA/DAID card on PIM2, PIM4 When Main PIM is 5 or 6 PIM configuration, the DAIA/DAID card must be mounted on PIM2 and/or PIM4, and connected as follows: RMT BUS CA-A 5 PIM 6 PIM NOTE:DAIA/DAID card must be mounted in even-numbered PIMs. When mounted in PIM0 BWB BUS connector, BUS1B or BUS0B may be used for this...
Page 34
NEAX2000 IVS2 Remote PIM System ManualPage 26 ND-70917 (E), Issue 1.0 CHAPTER 2 INSTALLATION Installation for Main Site (2) Cable Connection Between DAIA/DAID Cards If two or three DAIA/DAID cards are mounted on one PIM, connect between the PCM0 connector and PCM1 connector on the DAIA/DAID cards by 17-TW-0.3 CONN CA-A, as shown in Figure 2-5. Up to three DAIA/DAID cards can be connected directly by a daisy chain connection on one PIM. Figure 2-5 DAIA/DAID Between DAIA/DAID Cable Connection...
Page 35
CHAPTER 2 INSTALLATION Installation for Main Site NEAX2000 IVS2 Remote PIM System Manual ND-70917 (E), Issue 1.0 Page 27 (3) Cable Connection Between DAIA/DAID Card and DAIC/DAIF Card Connect between the RBUS connector on the DAIC/DAIF card and the BUS connector on the DAIA/DAID card by 48-TW-0.2 CONN CA, as shown in Figure 2-6. Up to two DAIC cards can be mounted per DAIA card. Only one DAIF card can be mounted per DAID card. Figure 2-6 DAIA/DAID Between DAIC/DAIF Cable Connection (1 of 2) :...
Page 36
NEAX2000 IVS2 Remote PIM System ManualPage 28 ND-70917 (E), Issue 1.0 CHAPTER 2 INSTALLATION Installation for Main Site Figure 2-6 DAIA/DAID Between DAIC/DAIF Cable Connection (2 of 2) : 17-TW-0.3 CONN CA-A When mounting 3 DAIA/DAID cards and 3 DAIC/DAIF cards : 48-TW-0.2 CONN CA BUS TBUS RBUS PCM1 PCM0 DAIC DAIA /DAIF /DAIDDAIC DAIA /DAIF /DAIDDAIC DAIA /DAIF /DAID When mounting 3 DAIA cards and 6 DAIC cards BUS TBUS RBUS PCM1 PCM0 DAICDAIA DAICDAIA DAICDAIA
Page 37
CHAPTER 2 INSTALLATION Installation for Remote Site NEAX2000 IVS2 Remote PIM System Manual ND-70917 (E), Issue 1.0 Page 29 INSTALLATION FOR REMOTE SITE Mounting DAIB Card for T1 / DAIE Card for E1 (1) Before mounting the DAIB/DAIE card, set the MB switch to UP position, and set the other switches to appropriate position. See CHAPTER 4. (2) Mount the DAIB/DAIE card in the MP slot on Remote PIM. After mounting the card, set the MB switch to DOWN position. Mounting DAIC Card for T1 / DAIF Card for...
Page 38
NEAX2000 IVS2 Remote PIM System ManualPage 30 ND-70917 (E), Issue 1.0 CHAPTER 2 INSTALLATION Installation for Remote Site BUS Cable Connection Connect between the BUS connector on the DAIB/DAIE card and the RBUS connector on the DAIC/DAIF card by the 48-TW-0.2 CONN CA, as shown in Figure 2-7. Figure 2-7 DAIB/DAIE Between DAIC/DAIF Cable Connection DAICDAIB TBUS RBUSBUS • When mounting 1 DAIC/DAIF card DAIC TBUS RBUSBUSDAIC When mounting 2 DAIC cards /DAIF/DAIE DAIB 48-TW-0.2 CONN CA 48-TW-0.2 CONN CA
Page 39
CHAPTER 2 INSTALLATION Installation for Remote Site NEAX2000 IVS2 Remote PIM System Manual ND-70917 (E), Issue 1.0 Page 31 Mounting Line/Trunk Card for T1 (1) Mount line/trunk cards in the LT slots on the Remote PIM. (2) Connect the line cables by referring to Figure 2-8 and Ta b l e 2 - 1. Figure 2-8 Mounting Location of Line/Trunk Card for T1 Table 2-1 LTC Connector Accommodation for T1 LTC CONNECTOR CARD SLOT NUMBER LT C 0 LT 0 0 ~ LT 0 2 LT C 1 LT 0 3 ~ LT 0 5 LT C 2 LT 0 6 ~ LT 0 8 LT C 3...
Page 40
NEAX2000 IVS2 Remote PIM System ManualPage 32 ND-70917 (E), Issue 1.0 CHAPTER 2 INSTALLATION Installation for Remote Site Figure 2-9 Location of Each LEN for T1 NOTE 1:A maximum of 63 line/trunks can be accommodated in one Remote PIM. NOTE 2:In Slot 08-11, only 4-port line/trunk cards are mountable. When the following 8-port cards are mounted in Slot 04-07, any line/trunk cards are not mountable in Slot 08-11. 8COT, 8DLC, 8LC, 8RSTA, 4DAT, CFTB, 2CSI, 2ILC When opposite DAIA card is set to FP No....