Page 41
CHAPTER 2 INSTALLATION Installation for Remote Site NEAX2000 IVS2 Remote PIM System Manual ND-70917 (E), Issue 1.0 Page 33 Figure 2-10 LTC Connector Pin Arrangement for T1 (1 of 2) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25(FP1) LEN 200 201 202 203 204 205 206 207 208 209 210 211 212 213 214 215 216 217 218 219 220 221 222 LEN 223(FP2) /400 /401 /402 /403 /404 /405 /406 /407 /408 /409 /410 /411 /412 /413 /414 /415 /416 /417 /418 /419 /420 /421 /422 /423 (FP3)...
Page 42
NEAX2000 IVS2 Remote PIM System ManualPage 34 ND-70917 (E), Issue 1.0 CHAPTER 2 INSTALLATION Installation for Remote Site Figure 2-10 LTC Connector Pin Arrangement for T1 (2 of 2) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25(FP1) LEN 248 249 250 251 252 253 254 255 256 257 258 259 260 261 262 263 236 237 238 LEN 239(FP2) /448 /449 /450 /451 /452 /453 /454 /455 /456 /457 /458 /459 /460 /461 /462 /463 /436 /437 /438 /439 (FP3) /648 /649 /650 /651 /652 /653 /654 /655 /656...
Page 43
CHAPTER 2 INSTALLATION Installation for Remote Site NEAX2000 IVS2 Remote PIM System Manual ND-70917 (E), Issue 1.0 Page 35 Mounting Line/Trunk Card for E1 (1) Mount line/trunk cards in the LT slots on the Remote PIM. (2) Connect the line cables by referring to Figure 2-11 and Ta b l e 2 - 2. Figure 2-11 Mounting Location of Line/Trunk Card for E1 Table 2-2 LTC Connector Accommodation for E1 LTC CONNECTOR CARD SLOT NUMBER LT C 0 LT 0 0 ~ LT 0 2 LT C 1 LT 0 3 ~ LT 0 5 LT C 2 LT 0 6 ~ LT 0 8 LT C...
Page 44
NEAX2000 IVS2 Remote PIM System ManualPage 36 ND-70917 (E), Issue 1.0 CHAPTER 2 INSTALLATION Installation for Remote Site Figure 2-12 Location of Each LEN for E1 When opposite DAID card is set to FP No. 1: When opposite DAID card is set to FP No. 2: When opposite DAID card is set to FP No. 3: NOTE 1:A maximum of 60 line/trunks can be accommodated in one Remote PIM. NOTE 2:In Slot 08-11, only 4-port line/trunk cards are mountable. When the following 8-port cards are mounted in Slot 04-07, any...
Page 45
CHAPTER 2 INSTALLATION Installation for Remote Site NEAX2000 IVS2 Remote PIM System Manual ND-70917 (E), Issue 1.0 Page 37 Figure 2-13 LTC Connector Pin Arrangement for E1 (1 of 2) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25(FP1) LEN 200 201 202 203 204 205 206 207 208 209 210 211 212 213 214 215 216 217 218 219 220 221 222 LEN 223(FP2) /400 /401 /402 /403 /404 /405 /406 /407 /408 /409 /410 /411 /412 /413 /414 /415 /416 /417 /418 /419 /420 /421 /422 /423 (FP3)...
Page 46
NEAX2000 IVS2 Remote PIM System ManualPage 38 ND-70917 (E), Issue 1.0 CHAPTER 2 INSTALLATION Installation for Remote Site Figure 2-13 LTC Connector Pin Arrangement for E1 (2 of 2) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25(FP1) LEN 248 249 250 251 252 253 254 255 256 257 258 259 260 261 262 263 236 237 238 LEN 239(FP2) /448 /449 /450 /451 /452 /453 /454 /455 /456 /457 /458 /459 /460 /461 /462 /463 /436 /437 /438 /439 (FP3) /648 /649 /650 /651 /652 /653 /654 /655 /656...
Page 47
CHAPTER 2 INSTALLATION Installation for Remote Site NEAX2000 IVS2 Remote PIM System Manual ND-70917 (E), Issue 1.0 Page 39 Power Failure Transfer (AUC) The PN-AUC card can be used as the PFT card at the Remote Site. Figure 2-14 shows an outline of a PFT (PN-AUC) connection. Figure 2-15 shows the MDF cross connection for a PFT (PN-AUC). Figure 2-14 PFT Connection Outline (AUC) MDF TEL PN-AUCRemote PIM MDF PN-4COTTO C.O. LINE
Page 48
NEAX2000 IVS2 Remote PIM System ManualPage 40 ND-70917 (E), Issue 1.0 CHAPTER 2 INSTALLATION Installation for Remote Site Figure 2-15 MDF Cross Connection for PFT (AUC) (1 of 2) 1 26 2 27 3 28 4 29 9 34 10 35 C.O.R0 C.O.T0 C.O.R1 C.O.T1 PN-4COT1 26 2 27 3 28 4 29 TO STATIONSta. R0 Sta. T0 Sta. R1 Sta. T1 MDF REMOTE PIM PN-AUC LT00 9 34 10 35 JPLTC0 4Q-TW-0.3 CONN CA LT01 LEN000 (No. 0) LEN001 (No. 1) CN1 04 03 02 01 CN1 04 03 02 01LEN008 (No. 0) LEN009 (No. 1) Ring TO STATION Tip Tip Ring TO C.O....
Page 49
CHAPTER 2 INSTALLATION Installation for Remote Site NEAX2000 IVS2 Remote PIM System Manual ND-70917 (E), Issue 1.0 Page 41 Figure 2-15 MDF Cross Connection for PFT (PN-AUC) (2 of 2) NOTE 1:The No. 2 and No. 3 circuit in the PN-4COT card cannot be used with the PFT function. NOTE 2:When using Ground Start trunks with the PFT function, the single line stations must have a ground sending button and a ground lead must be run to the station. 1 C.O.R0 26 C.O.T0 2 C.O.R1 27 C.O.T1 LTC0 (J) 26 C.O.T0 1...
Page 50
NEAX2000 IVS2 Remote PIM System ManualPage 42 ND-70917 (E), Issue 1.0 CHAPTER 2 INSTALLATION Installation for Remote Site Power Failure Transfer (8PFT) The PZ-8PFTB card can be used as the PFT card at the Remote Site. Figure 2-16 shows an outline of a PFT (PZ-8PFTB) connection. Figure 2-16 PFT Connection Outline (8PFT) PZ-8PFTB Remote PIM MDF MDFMDF MDF TO C. O. LINE PN-8LC PN-8COT TEL NOTE NOTE:Using the PN-AUC card (long line card) instead of the PN-8LC card is not recommended due to the...