Page 61
CHAPTER 2 TROUBLESHOOTING Precautions NEAX2000 IVS2 Maintenance Manual ND-70926 (E), Issue 1.0 Page 53 Static Electricity Guard You must wear a grounded wrist strap to protect circuit cards from static electricity. Figure 2-1 Static Electricity Guard (1 of 2) WHEN PLUGGING/UNPLUGGING A CIRCUIT CARD WHEN HOLDING A CIRCUIT CARD PBX WRIST STRAP FRAME GROUND SCREW CARD FRONT NEVER TOUCH THE COMPONENTS OR SOLDERED SURFACE WITH BARE HANDS.
Page 62
NEAX2000 IVS2 Maintenance ManualPage 54 ND-70926 (E), Issue 1.0 CHAPTER 2 TROUBLESHOOTING Precautions Figure 2-1 Static Electricity Guard (2 of 2) WHEN MAKING A SWITCH SETTING ON A CIRCUIT CARD WHEN CARRYING A CIRCUIT CARD WEAR A WRIST STRAP AND PERFORM THE WORK ON A GROUNDED CONDUCTIVE WORK SURFACE. CIRCUIT CARD WHEN CARRYING A CIRCUIT CARD AROUND, KEEP THE CARD IN A CONDUCTIVE POLYETHYLENE BAG. CIRCUIT CARDCONDUCTIVE POLYETHYLENE BAG
Page 63
CHAPTER 2 TROUBLESHOOTING Precautions NEAX2000 IVS2 Maintenance Manual ND-70926 (E), Issue 1.0 Page 55 CAUTION You must hold the edge of a circuit card when plugging or unplugging the circuit card. If you touch another area, you may be exposed to hazardous voltages. CARD FRONT NEVER TOUCH THE COMPONENTS OR SOLDERED SURFACE WITH BARE HANDS. PBX
Page 64
NEAX2000 IVS2 Maintenance ManualPage 56 ND-70926 (E), Issue 1.0 CHAPTER 2 TROUBLESHOOTING Precautions Turning Power ON (1) Check the switch position of each PZ-PW121 card before turning power on. Make sure that the AC120V/240V selector switch is positioned to appropriate voltage for each country (AC120V or AC240V). Make sure that the battery mode selector switch is positioned as shown below to meet the kind of battery: (2) Turn the SW1 switches of all the PZ-PW121 cards to ON. First, turn ON PIM1...
Page 65
CHAPTER 2 TROUBLESHOOTING Precautions NEAX2000 IVS2 Maintenance Manual ND-70926 (E), Issue 1.0 Page 57 Turning Power OFF (1) Before turning power off, make sure that all line/trunk cards are not operating by no busy lamps indication. (2) Turn the SW1 switches of all the PZ-PW121 cards to OFF. First, turn OFF PIM0. Then, turn OFF PIM1 to PIM7.
Page 66
NEAX2000 IVS2 Maintenance ManualPage 58 ND-70926 (E), Issue 1.0 CHAPTER 2 TROUBLESHOOTING Outline of Troubleshooting OUTLINE OF TROUBLESHOOTING Figure 2-2 shows an outline of the recommended troubleshooting procedure. Figure 2-2 Troubleshooting Outline START FAULT DIAGNOSIS AND TROUBLESHOOTING Fault Detection Method (See Page 59.) (1) Alarm Indication on PWRU, Alarm Display Panel (2) Lamp Indication on Circuit Cards (3) Complaint from station user or operator Fault Diagnosis and Troubleshooting...
Page 67
CHAPTER 2 TROUBLESHOOTING Fault Detection NEAX2000 IVS2 Maintenance Manual ND-70926 (E), Issue 1.0 Page 59 FAULT DETECTION This section describes the way in which alarm indications are given. If a fault occurs in the sys- tem, you can detect the fault via the routes shown in Figure 2-3. Figure 2-3 Alarm Indication Routes PWR CARD MJ MN ON PWR MJMN ALARM DISPLAY PANEL MJ/MN ALARM INDICATION MJ/MN ALARM INDICATION LAMP INDICATION CIRCUIT CARD MAINTENANCE PERSONNEL COMPLAINT FROM STATION USER OR...
Page 68
NEAX2000 IVS2 Maintenance ManualPage 60 ND-70926 (E), Issue 1.0 CHAPTER 2 TROUBLESHOOTING Fault Detection (1) Fault Detection by Alarm Indication When a fault occurs in the system, you can detect the fault by a Major (MJ) alarm or Minor (MN) alarm indicated on the AC/DC PWR card or by the external Alarm Display Panel. (2) Fault Detection by Lamp Indication on Circuit Cards When a fault occurs in the system, you can detect the fault by lamp indication on circuit cards, such as a Major (MJ) or Minor...
Page 69
CHAPTER 2 TROUBLESHOOTING Fault Detection NEAX2000 IVS2 Maintenance Manual ND-70926 (E), Issue 1.0 Page 61 Table 2-2 Lamp Indications on Circuit Cards KIND OF CIRCUIT CARDCARD NAMELAMP NAMECOLORINDICATIONS NORMAL ABNORMAL Control Cards PN-CP14 (MP) RUN Green 120 IPM Flash Steady ON or OFF PN-CP15 (FP) RUN Green 120 IPM Flash Steady ON or OFF PN-PW00 (EXTPWR)RUN Green Steady ON OFF PZ-PW121 (AC/DC PWR)ON Green Steady ON OFF PZ-PW122 (DC/DC PWR)ON Green Steady ON OFF Application Processor...
Page 70
NEAX2000 IVS2 Maintenance ManualPage 62 ND-70926 (E), Issue 1.0 CHAPTER 2 TROUBLESHOOTING Fault Detection Application Processor CardsPN-30DTC-A (DTI)RUN Green 120 IPM Flash Steady ON or OFF AIS Red OFF Steady ON MRMT Red OFF Steady ON RMT Red OFF Steady ON MFRM Red OFF Steady ON FRM Red OFF Steady ON PCM Red OFF Steady ON PN-24PRT (PRT)RUN Green 120 IPM Flash Steady ON or OFF LC Green Steady ON OFF AIS Red OFF Steady ON RMT Red OFF Steady ON FRM Red OFF Steady ON PCM Red OFF Steady ON CRC Red OFF...