NEC Neax 2000 Ivs2 Maintenance Manual
Here you can view all the pages of manual NEC Neax 2000 Ivs2 Maintenance Manual. The NEC manuals for Communications System are available online for free. You can easily download all the documents as PDF.
Page 111
CHAPTER 2 TROUBLESHOOTING Fault Diagnosis and Troubleshooting NEAX2000 IVS2 Maintenance Manual ND-70926 (E), Issue 1.0 Page 103 (3) If Dial Tone is returned after seizing the original trunk, there is a problem with the distant office, the Carrier Equipment, or the line. (4) If not, check for trouble with wiring on the MDF and the trunk card. Any dialed digit is not transmit- ted to the distant office.(1) System Data Programming for the trunk route: CM35 Y=01, 08, 20 (2) When the Sender...
Page 112
NEAX2000 IVS2 Maintenance ManualPage 104 ND-70926 (E), Issue 1.0 CHAPTER 2 TROUBLESHOOTING Fault Diagnosis and Troubleshooting After dialing the first digit, Dial Tone from the distant office is not disconnected.(1) Appropriate signal (DP/DTMF) to distant office is transmitted. System Data Programming for DP signal: CM35 Y=01, 13, 23, 25, 45 System Data Programming for DTMF signal: CM35 Y=01, 13, 24, 26, 46 (2) System Data Programming for Numbering Plan: CM20>A100- A163,...
Page 113
CHAPTER 2 TROUBLESHOOTING Fault Diagnosis and Troubleshooting NEAX2000 IVS2 Maintenance Manual ND-70926 (E), Issue 1.0 Page 105 (2) On Incoming Call C.O. Incoming Call is not termi- nated to ATTCON Station, DIT or TAS Buzzer. BL lamp on the trunk card is not turned on.(1) Disconnect the trunk from the line on the MDF. (2) Connect a test telephone set to the line on the MDF. (3) If the telephone rings, check for trouble with wiring on the MDF and the trunk card. (4) If not, there is a...
Page 114
NEAX2000 IVS2 Maintenance ManualPage 106 ND-70926 (E), Issue 1.0 CHAPTER 2 TROUBLESHOOTING Fault Diagnosis and Troubleshooting No Dial Tone Connection on Tie Line Incoming Call (only for the 2nd dial tone system)(1) In case all Tie Line Trunks fail, check if DTMF Receivers for Tie Line Incoming Call are installed (only when the signal kind of the trunk is DTMF). In case of ODT card (1) System Data Programming for the trunk: CM35 Y=00, 09, 10. (2) Disconnect trunk from the line on the MDF....
Page 115
CHAPTER 2 TROUBLESHOOTING Fault Diagnosis and Troubleshooting NEAX2000 IVS2 Maintenance Manual ND-70926 (E), Issue 1.0 Page 107 The Tie Line Incoming Call/DID Call is routed to a different station other than the dialed station, or to Reorder Tone.(1) System Data Programming for the trunk: CM35 Y=01, 17, 61-68 (1) Trunk card (2) FP card (3) MP card B END CHECK REPLACE
Page 116
NEAX2000 IVS2 Maintenance ManualPage 108 ND-70926 (E), Issue 1.0 CHAPTER 2 TROUBLESHOOTING Fault Diagnosis and Troubleshooting (3) On Answering the Call Speech Path Trouble: No connection/One way connection(1) Disconnect the trunk from the line on the MDF. (2) To perform the Speech Path Test internally, make the following connection on the MDF according to type of card. START ACHECK MDF ODT ODTE M E M MDF COT ATTCON STATION PORT In Case of COT Card In Case of ODT Card
Page 117
CHAPTER 2 TROUBLESHOOTING Fault Diagnosis and Troubleshooting NEAX2000 IVS2 Maintenance Manual ND-70926 (E), Issue 1.0 Page 109 (3) If the trouble remains, replace the trunk card. (4) If not, there is a problem with the distant office. (1) Trunk card (2) FP card (3) MP card Call is dropped (This condition excludes the Line Fault detected within a system). When the station user flashes the switch-hook(1) System Data Programming for the trunk: CM35 Y=16 When the failure occurs...
Page 118
NEAX2000 IVS2 Maintenance ManualPage 110 ND-70926 (E), Issue 1.0 CHAPTER 2 TROUBLESHOOTING Fault Diagnosis and Troubleshooting Transmission quality is not acceptable. Noise/Distor tion (1) Cabling between the PBX and the MDF or between the MDF and the lines is properly run to avoid induction from an AC power cable, motor or power supply equipment. (1) Trunk card (2) FP card (3) MP card (4) PWR card Low Voice Level (1) Loose connection of cables on the MDF (1) Trunk card (2) FP card (3) MP...
Page 119
CHAPTER 2 TROUBLESHOOTING Fault Diagnosis and Troubleshooting NEAX2000 IVS2 Maintenance Manual ND-70926 (E), Issue 1.0 Page 111 POWER FAILURE TRANSFER (PFT) FAULT Preassigned stations are not connected to the C.O. line when system alarm or power failure has occurred.(1) Cross connection on the MDF is properly made. (2) Proper connection between the AUC card and the COT card (1) AUC card PFT operates without Power Failure or Emergency Alarm.(1) AUC card (2) MP card START END CHECK REPLACE...
Page 120
NEAX2000 IVS2 Maintenance ManualPage 112 ND-70926 (E), Issue 1.0 CHAPTER 2 TROUBLESHOOTING Fault Diagnosis and Troubleshooting Dterm FAULT This troubleshooting procedure covers faults with the D term function only. For other faults, see Station Line Fault on Page 98. All Keys on the D term are ineffective.(1) Wiring on Modular Box (Rosette) (2) DLC card is properly mounted. (3) System Data Programming for the D term station: CM10, CM11, CM12, CM13, CM90, CM93 (4) RUN lamp on the FP card and MP...