NEC Neax 2000 Ivs2 Maintenance Manual
Here you can view all the pages of manual NEC Neax 2000 Ivs2 Maintenance Manual. The NEC manuals for Communications System are available online for free. You can easily download all the documents as PDF.
Page 81
CHAPTER 2 TROUBLESHOOTING Fault Diagnosis and Troubleshooting NEAX2000 IVS2 Maintenance Manual ND-70926 (E), Issue 1.0 Page 73 16 Periodic maintenanceInspection kind 00: Battery check Exchange the battery. 20 DTI line failure 3: XX XX XX XX Fault Details Kind (See below.) Fault Detail Kind 00: PCM Loss Check the DTI cable connection. Fault Detail Kind 01: Frame Loss Fault Detail Kind 02: Multi frame Loss Fault Detail Kind 03: AIS error Fault Detail Kind 04: Remote alarmReplace the DTI card....
Page 82
NEAX2000 IVS2 Maintenance ManualPage 74 ND-70926 (E), Issue 1.0 CHAPTER 2 TROUBLESHOOTING Fault Diagnosis and Troubleshooting 24 [Australia Only]Number of faulty trunks was more than predeter- mined numberSearch for a line fault trunk by CMB0 Y=1 or CMF5 Y=0. Check to see if the trunk line is faulty. 25 Number of line lockout stations was more than predetermined numberSearch for stations in line lockout by the configuration repor t on the MAT. Place the handset of any station in line...
Page 83
CHAPTER 2 TROUBLESHOOTING Fault Diagnosis and Troubleshooting NEAX2000 IVS2 Maintenance Manual ND-70926 (E), Issue 1.0 Page 75 26 DLC card down 3: XX XX XX XX 4: XX XX XX XX DLC Failure Kind (See below.) LEN (000-763) Station No. (X - XXXXXXXX) DLC Failure Kind 00: Terminal was cut offCheck the cable connection between the terminal and the PBX. Check to see if the cable is cut off. Check to see if the Tip wire of the cable is grounded. DLC Failure Kind 02: Short circuit was made on the...
Page 84
NEAX2000 IVS2 Maintenance ManualPage 76 ND-70926 (E), Issue 1.0 CHAPTER 2 TROUBLESHOOTING Fault Diagnosis and Troubleshooting 26 DLC card down DLC Failure Kind 05: Terminal failureReplace the terminal with a known good one and check to see if the same failure occurs. DLC Failure Kind 08: Terminal circuit failureReplace the terminal with a known good one and check to see if the same failure occurs. 27 Synchronism of DPC missed3: XX XX XX XX DPC Failure Kind DPC Number DPC Failure Kind 00:...
Page 85
CHAPTER 2 TROUBLESHOOTING Fault Diagnosis and Troubleshooting NEAX2000 IVS2 Maintenance Manual ND-70926 (E), Issue 1.0 Page 77 28 SMDR output buffer memory overflowMemory kind 02: Automatic print Buffer memory block Memory kind 03: Automatic print Buffer memory blockConfirm if the printer power is on or printer is out of paper. Memory kind 04: Notice of the rest of memory block numbers in the system Memory kind 05: CCIS output Buffer memory block Memory kind 06: CS repor t traffic...
Page 86
NEAX2000 IVS2 Maintenance ManualPage 78 ND-70926 (E), Issue 1.0 CHAPTER 2 TROUBLESHOOTING Fault Diagnosis and Troubleshooting Table 2-4 Fault Restoration Information FAU LT RESTORATION KIND NUMBERFAULT RESTORATION CONTENTFAULT RESTORATION INFORMATION 18 AP card returned to normal condition3: XX XX XX XX FP/AP Number 00-03 : FP No. 0-3 04-15, 20-31: AP No. 4-15, 20-31 19 Power failure returned to normal condition3: XX XX XX XX Power Failure Restoration Kind 00: AC input failure 01: Fuse...
Page 87
CHAPTER 2 TROUBLESHOOTING Fault Diagnosis and Troubleshooting NEAX2000 IVS2 Maintenance Manual ND-70926 (E), Issue 1.0 Page 79 35 Number of lockout stations was less than predetermined number 36 DLC returned to normal condition3: XX XX XX XX 4: XX XX XX XX DLC Failure Kind 00: Terminal was cut off 02: Short circuit was made on the line 03: Ring wire was grounded 04: Tip wire was grounded or ter- minal was unconnected 05: Terminal failure 08: Terminal circuit failure LEN (000-763) Station...
Page 88
NEAX2000 IVS2 Maintenance ManualPage 80 ND-70926 (E), Issue 1.0 CHAPTER 2 TROUBLESHOOTING Fault Diagnosis and Troubleshooting STATION LINE STATUS DISPLAY Item (1) shows the display format for the Station Line Status Display feature, and item (2) shows the fault diagnosis and troubleshooting method. For details of the Station Line Status Display feature, see Station Line Status Display on Page 32. (1) Display Format (2) Fault Diagnosis and Troubleshooting Table 2-5 shows the line status and the...
Page 89
CHAPTER 2 TROUBLESHOOTING Fault Diagnosis and Troubleshooting NEAX2000 IVS2 Maintenance Manual ND-70926 (E), Issue 1.0 Page 81 Table 2-5 Line Status and Remedial Action INDICATED DATASINGLE LINE TELEPHONE D term LINE STATUSREMEDIAL ACTIONLINE STATUSREMEDIAL ACTION Hardware Test 00 Terminal is not con- nectedCheck the cable connection between the terminal and the PBX. Check to see if the cable is cut off.Terminal is not con- nected or Tip wire is groundedCheck the cable connection...
Page 90
NEAX2000 IVS2 Maintenance ManualPage 82 ND-70926 (E), Issue 1.0 CHAPTER 2 TROUBLESHOOTING Fault Diagnosis and Troubleshooting Software Test 01 Idle No action is required. Idle No action is required. 02 Line LockoutPlace the handset of the station in line lockout back onto the hookswitch.Line LockoutPlace the handset of the station in line lockout back onto the hookswitch. Other than 01, 02 Busy No action is required. Busy No action is required. Table 2-5 Line Status and Remedial Action...