CHAPTER 2  TROUBLESHOOTING
Fault Diagnosis and Troubleshooting
NEAX2000 IVS2 Maintenance Manual    
ND-70926 (E), Issue 1.0   Page 83
Lamp Indication on Cards
This section describes the method for fault diagnosis and troubleshooting when you detect the
fault occurrence by lamp indication on circuit cards.
Table 2-6 shows the contents of the fault and the remedial action on each lamp status.
Table 2-6  Remedial Action on Each Lamp Status 
CARD NAME LAMP STATUSFAU LT
CONTENTREMEDIAL ACTION
PN-CP14 (MP) RUN...

Page 92

 NEAX2000 IVS2 Maintenance ManualPage 84  ND-70926 (E), Issue 1.0
CHAPTER 2  TROUBLESHOOTING
Fault Diagnosis and Troubleshooting
PN-PW00
(EXTPWR)RUN lamp is not 
on-48V power is not 
being suppliedConfirm the lamp indication of 
PZ-PW121 all lamps.
If the fault cannot be cleared, 
replace the PN-PW00 card.
If PZ-PW121 lamp has abnormal 
condition, replace the PZ-PW121 
card.
PZ-PW121
(AC/DC PWR)ON lamp is not 
onOperation power 
is not being 
suppliedConfirm the connection of PZ-
PW121 and PZ-PW122.
Turn...

Page 93

CHAPTER 2  TROUBLESHOOTING
Fault Diagnosis and Troubleshooting
NEAX2000 IVS2 Maintenance Manual    
ND-70926 (E), Issue 1.0   Page 85
PN-AP00-B
 (AP00)RUN lamp is not 
flashingAbnormal 
operation of 
AP00 cardConfirm the programming data: 
CM05.
Check to see if the SENSE switch 
is set as per the AP Number (04-
15, 20-31) assigned by CM05.
Reset the MB switch. 
(Down→
Up→
Down)
Check the setting of SW1.
SW1-1: ON
SW1-2: ON
SW1-3: ON
If the fault cannot be cleared, 
replace the card.
PN-AP01 (AP01) RUN...

Page 94

 NEAX2000 IVS2 Maintenance ManualPage 86  ND-70926 (E), Issue 1.0
CHAPTER 2  TROUBLESHOOTING
Fault Diagnosis and Troubleshooting
PN-2BRTC
(BRT)RUN lamp is not 
flashingAbnormal 
operation of BRT 
cardConfirm the programming data: 
CM05.
Check to see if the SENSE switch 
is set as per the AP Number (04-
15, 20-31) assigned by CM05, 
CM07 Y=2.
Reset the MB switch.
(Down
→Up
→Down)
If the fault cannot be cleared, 
replace the card.
ALM0 lamp is on No.0 circuit 
transmission line 
faultConfirm No.0 circuit...

Page 95

CHAPTER 2  TROUBLESHOOTING
Fault Diagnosis and Troubleshooting
NEAX2000 IVS2 Maintenance Manual    
ND-70926 (E), Issue 1.0   Page 87
PN-24DTA-C
(DTI)RUN lamp is not 
flashingAbnormal 
operation of DTI 
cardConfirm the programming data: 
CM05, CM07 Y=01.
Check to see if the SENS switch 
is set as per the AP Number (04-
15, 20-31) assigned by CM05.
Reset the MB switch.
(Down→
Up→
Down)
If the fault cannot be cleared, 
replace the card.
CRC lamp is on Bit Error Rate 
exceeds the 
predetermined 
valueCheck...

Page 96

 NEAX2000 IVS2 Maintenance ManualPage 88  ND-70926 (E), Issue 1.0
CHAPTER 2  TROUBLESHOOTING
Fault Diagnosis and Troubleshooting
PN-30DTC-A
(DTI)RUN lamp is not 
flashingAbnormal 
operation of DTI 
cardConfirm the programming data: 
CM05, CM07 Y=01.
Check to see if the SENS switch 
is set as per the AP Number (04-
15, 20-31) assigned by CM05.
Reset the MB switch.
(Down
→Up
→Down)
If the fault cannot be cleared, 
replace the card.
PCM lamp is on No PCM signals 
arrive from the 
distant officeCheck to see...

Page 97

CHAPTER 2  TROUBLESHOOTING
Fault Diagnosis and Troubleshooting
NEAX2000 IVS2 Maintenance Manual    
ND-70926 (E), Issue 1.0   Page 89
PN-24PRT
(PRT)RUN lamp is not 
flashingAbnormal 
operation of PRT 
cardConfirm the programming data: 
CM05, CM07 Y=01.
Check to see if the SENS switch 
is set as per the AP Number (04-
15, 20-31) assigned by CM05.
Reset the MB switch.
(Down→
Up→
Down)
If the fault cannot be cleared, 
replace the card.
LC lamp is not 
onISDN primary 
rate D-channel 
data link 
connection...

Page 98

 NEAX2000 IVS2 Maintenance ManualPage 90  ND-70926 (E), Issue 1.0
CHAPTER 2  TROUBLESHOOTING
Fault Diagnosis and Troubleshooting
PN-4RSTB
(MFR)RUN lamp is not 
flashingAbnormal 
operation of MFR 
cardConfirm the programming data: 
CM05.
Check to see if the SENSE switch 
is set as per the AP Number (04-
15, 20-31) assigned by CM05.
Reset the MB switch.
(Down
→Up
→Down)
If the fault cannot be cleared, 
replace the card.
PN-4RSTC
(CIR)RUN lamp is not 
flashingAbnormal 
operation of CIR 
cardConfirm the...

Page 99

CHAPTER 2  TROUBLESHOOTING
Fault Diagnosis and Troubleshooting
NEAX2000 IVS2 Maintenance Manual    
ND-70926 (E), Issue 1.0   Page 91
PN-SC01 (DCH) RUN lamp is not 
flashingAbnormal opera-
tion of DCH cardConfirm the programming data: 
CM05.
Check to see if the SENS switch 
is set as per the AP Number (04-
15, 20-31) assigned by CM05.
Reset the MB switch.
(Down→
Up→
Down)
If the fault cannot be cleared, 
replace the card.
LC lamp is not 
onDCH D-channel 
link connection 
failureCheck the status of the...

Page 100

 NEAX2000 IVS2 Maintenance ManualPage 92  ND-70926 (E), Issue 1.0
CHAPTER 2  TROUBLESHOOTING
Fault Diagnosis and Troubleshooting
PN-SC03-A
(CSH)RUN lamp is not 
flashingAbnormal opera-
tion of CSH cardConfirm the programming data: 
CM05.
After confirmation of CM05, reset 
the system (Push the SW1 of 
MP).
Check to see if the SENS switch 
is set as per the AP Number (04-
15, 20-31) assigned by CM05. 
Reset the MB switch.
(Down
→Up
→Down)
If the fault cannot be cleared, 
replace the card.
DOPE lamp is 
not...