Page 21
CHAPTER 1 MAINTENANCE SERVICE FEATURES Fault Messages NEAX2000 IVS2 Maintenance Manual ND-70926 (E), Issue 1.0 Page 13 Table 1-2 Fault Restoration Kind Number FAULT KIND NUMBER FAULT RESTORATION CONTENT 18 FP/AP card returned to normal condition 19 Power failure returned to normal condition 30 DTI line returned to normal condition 31 DCH/BRT/PRT D-channel link connection returned to normal condition 32 CCH link connection returned to normal condition 34 [Australia Only]Number of faulty trunks was...
Page 22
NEAX2000 IVS2 Maintenance ManualPage 14 ND-70926 (E), Issue 1.0 CHAPTER 1 MAINTENANCE SERVICE FEATURES Fault Messages : External Alarm Kind (MJ/MN/–) External Alarm Kind—Minor (MN), Major (MJ), or no alarm (external alarm not provided) is programmed by CMEA Y=2. Table 1-3 shows the standard data set by the 2nd data=3 of CMEA Y=2. Table 1-3 Standard Data Set of External Alarm Kind FAU LT KINDFAULT CONTENTALARM KIND 01 System Initialization MN ALARM 04 MP-FP/AP communication failure MN ALARM 08...
Page 23
CHAPTER 1 MAINTENANCE SERVICE FEATURES Fault Messages NEAX2000 IVS2 Maintenance Manual ND-70926 (E), Issue 1.0 Page 15 The alarm lamps in Ta b l e 1 - 4 are indicated according to the alarm kind. 34 [Australia Only]Number of faulty trunks was less than predetermined number– 35 Number of lockout stations was less than predetermined number– 36 DLC card returned to normal condition– 37 Synchronism of DPC returned to normal– 38 SMDR output buffer memory returned to normal condition– 3B CS/ZT...
Page 24
NEAX2000 IVS2 Maintenance ManualPage 16 ND-70926 (E), Issue 1.0 CHAPTER 1 MAINTENANCE SERVICE FEATURES Fault Messages - : Fault Information/Fault Restoration Information Table 1-5 Fault Information FAU LT KIND NUMBER 01 Initial Kind, ,System Initialization Information 04 Communication Failure KindNumber of Communication FailuresFP/AP No. 08 FP/AP No. 09 Power Failure Kind 1 Power Failure Kind 2 Power Failure Kind 3 12 Fault Kind AP No. CS/ZT Interface No. 16 Inspection Kind 20 Fault...
Page 25
CHAPTER 1 MAINTENANCE SERVICE FEATURES Fault Messages NEAX2000 IVS2 Maintenance Manual ND-70926 (E), Issue 1.0 Page 17 Table 1-6 Fault Restoration Information FAU LT KIND NUMBER 18 FP/AP No. 19 Power Failure Kind 1 Power Failure Kind 2 Power Failure Kind 3 30 Fault Detail Kind 31 D-ch No. 32 CCH No. 34 35 36 DLC Failure Kind LEN Station No. 37 DPC Failure Kind DPC No. 38 Memory Kind 3B Fault Kind AP No. CS/ZT Interface No. 56789101112 e kkk l m n o pq r s t yzA
Page 26
NEAX2000 IVS2 Maintenance ManualPage 18 ND-70926 (E), Issue 1.0 CHAPTER 1 MAINTENANCE SERVICE FEATURES Fault Messages : Kind of System Initialization information (Upper digit) 1: Program address information 2: Receive command information F: No system initialization information : Initial Kind (Lower digit) 0: Power On Initialize 1: Initialize by Reset Button (SW1) 2: Serious failure 1 3: Serious failure 2 4: Not used 5: Serious failure 3 6: Serious failure 4 7: Serious failure 5 8: Serious failure 6 9:...
Page 27
CHAPTER 1 MAINTENANCE SERVICE FEATURES Fault Messages NEAX2000 IVS2 Maintenance Manual ND-70926 (E), Issue 1.0 Page 19 : Power Failure Kind 00: AC input failure 01: Fuse break 02: PWR alarm :Fault Kind 00: Fault notice from CS/ZT 01: CS/ZT initial failure 02: CS/ZT condition read failure 03: CS/ZT condition unmatch 04: B channel condition unmatch 05: SYS-ID upload failure 06: SYS-ID download failure 07: CS/ZT make busy failure 08: CS/ZT data load failure 09: B channel make busy failure 0A: CS/ZT...
Page 28
NEAX2000 IVS2 Maintenance ManualPage 20 ND-70926 (E), Issue 1.0 CHAPTER 1 MAINTENANCE SERVICE FEATURES Fault Messages : Fault Detail Kind 00: PCM loss 01: Frame loss 02: Multi frame loss 03: AIS error 04: Remote alarm 05: Multi remote alarm 06: S-bit error 07: Not used 08: CRC error 09: Slip detected 0A: Main signal all 1 (for BRT) 0B: INFO 0 (for BRT) 0C: INFO 2 (for BRT) 0D: Not used 0E: Not used 0F: Not used : D-channel Circuit No. DCH/BRT/PRT: 00-07 =D-channel No. 0-7 : CCH No. 00-07=CCH No. 0-7 :...
Page 29
CHAPTER 1 MAINTENANCE SERVICE FEATURES Fault Messages NEAX2000 IVS2 Maintenance Manual ND-70926 (E), Issue 1.0 Page 21 : DPC Failure Kind 00: DPC on the side of par tner 01: DPC on the side of oneself :DPC No. : Memory Kind 00: Billing memory block 01: Host CPU No. 0 output Buffer memory block 02: Host CPU No. 1 output Buffer memory block 03: Automatic print Buffer memory block 04: Notice of the rest of memory block numbers in the system 05: CCIS output Buffer memory block 06: CS report traffic...
Page 30
NEAX2000 IVS2 Maintenance ManualPage 22 ND-70926 (E), Issue 1.0 CHAPTER 1 MAINTENANCE SERVICE FEATURES Fault Messages : Fault Restoration Kind 00: CS/ZT connection returned 01: CS/ZT carrier has space : AP No. returned to normal condition : CS/ZT Interface No. returned to normal conditiony z A