Home
>
NEC
>
Communications System
>
NEC Neax 2000 Ivs2 Business/Hotel/Data Features And Specifications
NEC Neax 2000 Ivs2 Business/Hotel/Data Features And Specifications
Here you can view all the pages of manual NEC Neax 2000 Ivs2 Business/Hotel/Data Features And Specifications. The NEC manuals for Communications System are available online for free. You can easily download all the documents as PDF.
Page 101
CALL FORWARDINGCall Forwarding – Busy Line NEAX2000 IVS2 Business/Hotel/Data Features and SpecificationsPage 78 NDA-24271, Issue 1.0 From a Single Line Telephone To set Call Forwarding – Busy Line 1. Lift the handset and receive dial tone. 2. Dial the Call Forwarding – Busy Line feature access code and receive feature dial tone. 3. Dial the desired target station number and receive service set tone. To set Call Forwarding – Busy Line – Outside 1. Lift the handset and receive dial tone. 2. Dial the...
Page 102
CALL FORWARDINGCall Forwarding – No Answer NEAX2000 IVS2 Business/Hotel/Data Features and Specifications NDA-24271, Issue 1.0 Page 79 14. The setting stations trunk restriction class is used to allow or deny the tandem connection on a Call For- warding – Busy Line Outside. 15. Checking of the setting stations trunk restriction class can be allowed or denied on a system-wide basis. 16. A Direct Inward System Access (DISA) call to a station set for Call Forwarding – Busy Line Outside will be allowed or...
Page 103
CALL FORWARDINGCall Forwarding – No Answer NEAX2000 IVS2 Business/Hotel/Data Features and SpecificationsPage 80 NDA-24271, Issue 1.0 5. Replace the handset or press the Speaker key. To cancel Call Forwarding – No Answer 1. Lift handset or press Speaker key and receive dial tone. 2. Press the Call Forwarding – No Answer feature access key and receive special dial tone. Press the * key, the associated LED goes out and service set tone is received. The LCD displays CANCEL. From a Single Line Telephone...
Page 104
CALL FORWARDINGCall Forwarding – Destination NEAX2000 IVS2 Business/Hotel/Data Features and Specifications NDA-24271, Issue 1.0 Page 81 10. In the SMDR call record, the station that set Call Forwarding – No Answer – Outside will appear as the originator of the call. 11. SMDR only records if the Tandem Connection receives answer supervision. 12. The setting stations trunk restriction class is used to allow or deny the tandem connection on a Call For- warding – No Answer – Outside. 13. Checking of the...
Page 105
CALL FORWARDINGMultiple Call Forwarding – All Calls NEAX2000 IVS2 Business/Hotel/Data Features and SpecificationsPage 82 NDA-24271, Issue 1.0 To cancel Call Forwarding – Destination from destination station 1. Lift the handset or press the Speaker key and receive dial tone. 2. Press the Call Forwarding – Destination Cancel key or dial the Call Forwarding – Destination Cancellation code and receive feature dial tone. 3. Dial the users station number (forwarded station) and receive set tone. 4. Replace...
Page 106
CALL FORWARDINGMultiple Call Forwarding – All Calls NEAX2000 IVS2 Business/Hotel/Data Features and Specifications NDA-24271, Issue 1.0 Page 83 Service Conditions 1. Multiple Call Forwarding – All Calls can forward a maximum of five times when the called station sets Call Forwarding – All Calls to a station that has set Call Forwarding – All Calls or Call Forwarding – Busy Line. 2. Multiple Call Forwarding – All Calls cannot be performed for data calls. 3. If a calling station has been set to Call...
Page 107
CALL FORWARDINGMultiple Call Forwarding – Busy Line NEAX2000 IVS2 Business/Hotel/Data Features and SpecificationsPage 84 NDA-24271, Issue 1.0 Multiple Call Forwarding – Busy Line General Description This feature permits a call to a busy station to be forwarded, multiple times, to a predesignated idle station. Station Application All stations. Operating Procedure The same operating procedures for Call Forwarding – All Calls apply. Service Conditions 1. Multiple Call Forwarding – Busy Line can not be...
Page 108
CALL FORWARDINGSplit Call Forwarding – All Calls NEAX2000 IVS2 Business/Hotel/Data Features and Specifications NDA-24271, Issue 1.0 Page 85 Operating Procedure The same operating procedures for Call Forwarding – All Calls apply. Service Conditions 1. Multiple Call Forwarding – No Answer can only be performed for non-data calls. 2. Multiple Call Forwarding – No Answer can be forwarded as many times as desired. The call will stop for- warding when it terminates to the Attendant Console or to a station...
Page 109
CALL FORWARDINGSplit Call Forwarding – All Calls NEAX2000 IVS2 Business/Hotel/Data Features and SpecificationsPage 86 NDA-24271, Issue 1.0 From a Multiline Terminal with LCD To set split Call Forwarding – All Calls 1. Lift the handset or press the Speaker key and receive dial tone. 2. Press the Split Call Forwarding – All Calls feature access key and receive feature dial tone. 3. Dial the desired destination number (0-9) and receive service set tone. The associated LED lights and the LCD displays:...
Page 110
CALL FORWARDINGSplit Call Forwarding – All Calls NEAX2000 IVS2 Business/Hotel/Data Features and Specifications NDA-24271, Issue 1.0 Page 87 From a Single Line Telephone To set Split Call Forwarding – All Calls 1. Lift the handset and receive dial tone. 2. Dial the Call Forwarding – All Calls feature access code and receive feature dial tone. 3. Dial the desired destination number (0-9) and receive service set tone. 4. Replace the handset. To monitor Split Call Forwarding – All Calls 1. Lift the...