Page 571
The Maintenance Manager device identification device status background diagnostics on / off power up diagnostics on / off number of background tests pending number of system tests pending number of power up tests pending number of fault isolation tests pending number of power up diagnostic retries number of fault diagnostic retries number of user specified diagnostic retries number of requests for this card DEV PLID bay / slot / circuit / subcircuit CARDTYPE type of card CARDSTAT status of...
Page 573
5 Diagnostic Tests General 5.1 For each physical device in the SX-200 ML PABX there is a special set of diagnostic tests specifically designed to test the device as thoroughly as possible. If faults are detected, broader ranges of tests may be run in an attempt to isolate the fault to the board level, and to ensure that isolated faults are not merely side effects of other problems. Diagnostics are divided into four different functional groups to facilitate the different characteristics of the...
Page 574
General Maintenance information Table 5-2 Diagnostic Coverage Device Type I Power-up Background Directed I PROM ONS Line (digital) w COV Line (digital) w OPS Line (digital) LS/GS Trunk (digital) DID Trunk (digital) yes w w E&M Trunk Module (digital) Digital Line Card (DNIC) yes yes 9s DTMF Receiver Module ws w yes Music-on-Hold /Paging Module (cannot be tested, because the device is always busy) System Printer n/a nla Main Control Card II Digital Signal Processor (DSP) Bay Control...
Page 575
Diagnostic Tests Peripheral Device Tests ’ 5.4 There is a unique sequence of tests specifically designed for each type of peripheral device in the system. These test sequences include device-specific tests and common tests. The test sequences are described in Table 5-3 through Table 5-14. The actual tests are described in the following paragraphs. Refer to the Engineering hforrnat~on Practice for information on peripheral circuit hardware. AC CODEC loopback test: This test verifies the CODEC...
Page 576
General Maintenance Information DC CODEC test: This test verifies the operation of the PCM paths from the DX Matrix to the CODEC on the peripheral card and back again. It also verifies the integrity of a tone transmitted from the Main Control Card’s digital signal processor (DSP) along these paths. If the test fails, it is not possible for the system to isolate the fault com- pletely. Digital bay type test: Used to decide which set of diagnostics to run. If this routine returns a pass, digital bay...
Page 577
Diagnostic Tests Test DNIC output: This test is used to loop the data internally at DNIC output. Failure of this test will isolate the fault to the particular DNIC chip under test on the card. Tone detection test: This test generates a test tone of 440 Hz, and loops it back to the digital signal processor. The energy level of the tone must fall in a particular range to pass this test. Failure of the test indicates a faulty device. Tone generation test: This test collects two consecutive samples...
Page 578
General Maintenance Information Table 5-5 CO Trunk Card initialization Diagnostic State Test Name Circuit State If Test Passes Circuit State If Test Fails State 1 State 2 digital bay test adc reference test state 2 state 3 state 10 device failure unisolated I State 3 1 digital CODEC test 1 state 4 1 device failure unisolated 1 I State 4 digital CODEC state 5 device failure isolated loopback test I State 5 State 6 analog CODEC loopback test hybrid loopback test state 6 device passed...
Page 579
Diagnostic Tests Table 5-6 DID Trunk Card Initialization Diagnostic State State 1 State 2 State 3 State 4 Test Name Circuit State if Test Passes Circuit State if Test Fails acfc reference test state 2 device failure unisolated digital CODEC test state 3 device failure unisoiated digital CODEC state 4 device failure isolated loopback test analog CODEC device passed device failure isolated loopback test Table 5-7 Receiver Module Initialization Diagnostic State State 1 State 2 State 3...
Page 580
General Maintenance information Table 5-9 COV Card initialization Circuit State if Test Circuit State if Test Fails Circuit State if Test Circuit State if Test Fails Table 5-11 DID Card Initialization Circuit State if Test Fails 5-8 Issue 1 Revision 0 March 1997