Page 581

Diagnostic Tests 
Table 5-11 DID Card Initialization (continued) 
Diagnostic 
State Test Name Circuit State if Test 
Passes Circuit State if Test Fails 
I 1 1 
State 11 junctor ac CODEC test state 12 state 13 
State 12 junctor test state 14 state 13 
State 13 make junctor suspect state 9 state 9 
State 14 analog DSP test state 9 state 15 
State 15 retest primary state 15 state 16 
State 16 
State 17 retest secondary 
has junctor been 
isolated state 16 state 17 
state 18 device failure isolated 
State 18...

Page 582

General Maintenance Information 
Table 5-i 2 Digital Line Card Initialization (continued) 
Diagnostic 
Test Name Circuit State if Test 
State Passes Circuit State if Test Fails 
State 9 DNIC output loopback device passed device failure isolated 
test 
State 10 dataset data loopback device passed device failure isolated 
test 
State 11 DNIC input loopback state 2 device failure isolated 
test 
State 12 digital set transducer state 13 device failure isolated 
speaker test 
State 13 digital set transducer...

Page 583

6 Test Line 
General 
6.1 The test line interface is designed to provide the maintenance person with a portable, 
inexpensive, and readily available tool for diagnosing system failures and for 
performing maintenance functions. The test line interface provides a powerful subset 
of the maintenance functionality available through the maintenance terminal. In 
addition, the maintenance person can place calls without having a permanently wired 
extension on the premises. 
The connection to the default test...

Page 584

General Maintenance Information 
Table 6-l Test Line Command Codes 
Numeric Alpha Command Codes Description 
22 
BC Busy Out Channel (Remove Channel) 
25 
BJ Busv Out Junctor 
26 BO 
35 DL 
38 DT Busy Out device 
Dump Logs 
Direct Trunk select 
72 
FIG 
73 
SD 
77 FLS 
Return Channel 
Stop Dump Logs 
Return Device to Service 
t I I 7% ST 1 Stop Test Printers I I 
82 1 TC 1 Test Channel 
83 TD Test Device 
872 
TPB Test Printer Bay-Slot-Circuit I I 
873 1 TPE 1 Test Printer Extension-Number 
877 TPP Test...

Page 585

Test Line 
Dump Logs Command (DL) 
Allows the maintenance person to print the system maintenance log on to the system 
printer. 
I. Enter the test line access code 
2. Enter the Dump Logs code (35). 
“PA”on the status indicators and a single beep tone indicate that the system has started 
sending the logs to the printer. “FA” and reorder tone indicate failure. See Table 6-2. 
Direct Trunk Select Command (DT) 
Allows the maintenance person to directly select any trunk in the system from the test 
line....

Page 586

General Maintenance Information 
I. Enter the Test Line Access code 
2. Enter the Return Device to Service code (77) 
3. Enter the physical location number of the device. 
“PA” on the status indicators and a single beep tone will indicate that the device was 
returned to service. “FA” and reorder tone indicate failure. See Table 6-2. 
Stop Test Printers Command (ST) 
Allows the maintenance person to stop testing the printers on the system. 
I. Enter the Test Line Access code 
2. Enter the Stop Test...

Page 587

Test Line 
, “PA” on the status indicators and a single beep tone indicates that the system has 
started sending test data to the printer, which should then print two full pages of all the 8 
printable characters. “FA” and reorder tone indicates that the test failed. SeeTable 6-2. 3 
Test Printer Extension-Number Command (TPE) a 
Allows the maintenance person to test any printer on the system (except the system 
1 
z 
printer) using the extension number of the printer port. z 
. 
5 
I. Enter the Test...

Page 588

General Maintenance Information 
Test Line Indicator LEDs 
6.5 The status of the test line software is indicated by the dual seven-segment display 
status indicators on the Main Control Card Il. When the maintenance person enters 
the test line access code on the test line set, the LEDs go blank, indicating that the 
system is waiting for command input. After the maintenance person enters a 
command sequence, the LEDs will display the results of the action petformed. Refer 
to Table 6-2 for an...

Page 589

Test Line 
Test Line Tones 
6.6 The test line software uses some of the existing system-generated tones as audible 
status indicators. Approximately ten seconds after the maintenance person enters the 
test line access code on the test line set, a short ring burst, followed by dial tone is 
heard, indicating that the system is waiting for command input. After the maintenance 
person enters a command sequence, the returned tone will indicate the result of the 
action performed. See Table 6-3 for a...

Page 590

General Maintenance information 
6-8 Issue 1 
Revision 0 March 1997  