Maintenance Log Messages Table 7-4 Main Control Reset Log Reports Reset Log Message Main Control was reset due to power up Main Control was reset due to pushbutton Main Control was reset due to watch dog timer Main Control was reset due to local bay cause Main Control was reset due to msg link failure Main Control was reset due to software error Process 00 ANYTHING at address 012345 Main Control was reset due to software error Main Control was reset due to software error Process 00 has...
Page 452
Troubleshooting Table 7-6 Miscellaneous Log Reports Reset Log Message Action Required System Configuration/System ID module conflict. Change system configuration to clear error. Check the installation of the System ID module. Check Form 4 option selection. Log(s) deleted by user A user logged in to the maintenance facility (maintenance terminal or console) deleted one or more log entries via the DELETE LOGS command. Involved in recovery is 01 04 04 04 ext 1100 01 03 03 03 Trk 001 Main...
Page 453
8 Troubleshooting Aids Call Processing Information Table 8-l Digital Bay to Digital Bay Call Step Event 1. Caller in Bay 1 goes Off-Hook (the event). 2. The Bay Control Card (BCC) scans circuits on each card for events (hardware). 3. When an event occurs, the BCC assembles a message (in HDLC format) describing the event, the associated PLID, and the device which caused the event. 4. The message is then sent via a dedicated message channel to the Main Control Card II (MCC II). 5. The message is...
Page 454
Troubleshooting Table 8-l Digital Bay to Digital Bay Call (continued) I I Step Event 19. MCC II accepts the answer message, instructs the BCC to turn off the ringing being sent to the destination, turns off ringback tone being sent to the source, and then instructs the DX matrix to connect the source to the destination. This establishes the voice connection. 20. Conversation is carried out and completed. 21. One party hangs up. BCC detects and sends disconnect message to MCC Il. MCC II puts...
Page 455
TroubleshooGng Aids 2. insert an ammeter where the clip was. 3. Take current readings at the instant the trunk is seized, and after the call has been completed. Do this in both incoming and outgoing directions. 4. Release the trunk and repeat the measurements several times on the same Central Office at peak and low traffic hours. 5. Repeat the above steps using different Central Office trunks. Voltage Conversion Method. This method of loop current measurement should be used only in such instances...
Page 456
Troubleshooting Loop Stat-t Versus Ground Start Check The loop start versus ground start check should be performed as follows (also refer to Figure 8-2): 1. Locate the PBX trunk circuit Tip and Ring on the connecting block at the MDF. 2. Remove the bridge clips on the Tip and Ring (i.e., disconnect the PBX trunk circuit from the Central Office Tip and Ring). 3. Connect the butt set across the Central Office Tip and Ring. 4. Go off-hook with the butt set. If Central Office dial tone is returned,...
Page 459
SX-200@ ML PABX RS-232 Maintenance Terminal TM, @I - Trademark of Mite1 Corporation. @ Copvriaht 1997. Mite1 Corporation. @ MITEL’
Page 460
RS-232 Maintenance Terminal NOTICE The information contained in this document is believed to be accurate in all re- spects but is not warranted by Mite1 Corporation (MlTEL@). The information is subject to change without notice and should not be construed in any way as a commitment by Mite1 or any of its affiliates or subsidiaries. Mite1 and its affiliates and subsidiaries assume no responsibility for any errors or omissions in this doc- ument. Revisions of this document or new editions of it may...