Page 441
Maintenance Log Messages Table 7-l Fault Reports (continued) Alarm Code Message Action Required 111 LS/GStrnkcardfai1edat020201 OOTrkl Can’t Verify the wiring from the trunk circuit to the seize trunk AlarmCode= 111 public network. Correct as required. Refer to CO tnmk card failed at 02 02 0100 Trk 01 Can’t the /r~s~a//a~~or~ /r~~orrrra~io/~ Practice. if this is seize trunk Alarm Code = 111 not the problem, suspect failure or bad wiring at the Central Off ice. E&M trunk card failed at 02 02 0100...
Page 442
Troubleshooting Table 7-l Fault Reports (continued) Alarm Code Message Action Required 122 PFT sense passed at 00 00 08 00 The bay has been cut back to normal Bay has cut back Alarm Code = 122 operation. Verify that appropriate action was PFT sense passed at 03 00 00 00 taken to rectify the event which caused the Bay has cut back Alarm Code = 122 cut through. 123 ONS card failed at 02 01 01 00 ext 123 GENERAL: The recording device attached to Recording dev failed Alarm Code = 123 the specified...
Page 443
Maintenance Log Messages Table 7-l Fault Reports (continued) Alarm Code Message Action Required 129 ** anything ** failed at 00 00 00 00 Record this and watch for further occurrenc- Group-Link-Test not a proper member es. Perform a Verify Database operation and Alarm Code = 129 check for further occurrences of this Alarm * * anything * * failed at 00 00 00 00 Code. if system performance is degraded Group-Link-Test Invalid Group Link substantially, contact MITEL Field Service. Alarm Code = 129...
Page 444
Troubleshooting Table 7-l Fault Reports (continued) Jarm >ode Message Action Required 132 Key-DB-test failed at 00 00 00 00 Key 1 is not programmed as an INTERCOM ont’d) ICM is not key 1 key - key I must be an INTERCOM key. Key-DB-test failed at 00 00 00 00 The INTERCOM key is not programmed as ICM not immed ring IMMEDIATE RING - must be so. Key-DB-test failed at 00 00 00 00 The DIRECTION for the INTERCOM key is ICM not in and out not programmed as In/Out - must be so. Key-DB-test failed at 00...
Page 445
Maintenance Log Messages Table 7-l Fault Reports (continued) Alarm Code Message Action Required 141 Nil device failed at 00 00 00 00 The PMS system failed to respond to 20 PMS is down Alarm Code = 141 consecutive queries from the PABX. Refer to PMS procedures. 142 Nil device failed at 00 00 00 00 After failing to respond, the PMS system has PMS is up Alarm Code = 142 now responded to a PABX enquiry. 143 Nil device failed at 00 00 00 00 The system attempted to send a message to PMS buffer is...
Page 446
Troubleshooting Table 7-l Fault Reports (continued) Alarm Code Message Action Required 155 Tl trunk card at 01 06 01 00 Trk 019 The link has exceeded the specified (cont’d) has exceeded the service slip threshold threshold. A yellow alarm has been sent to the far end, and the link has been removed from service, and a new sync source selected. The RTS - Service Limit timer has been started. Refer to Ti Trunk troubleshooting procedures. Tl trunk card at 0106 01 00 Trk 019 has exceeded the maint...
Page 447
Maintenance Log Messages Table 7-l Fault Reports (continued) Alarm Code Message Action Required 155 Tl trunkcardatO1 0601 OOTrkO19 There is no synchronization detected on the (cont’d) is in red alarm condition due to loss of sync link; it has been removed from service. If this is the network sync source, a new source has been selected. Problem with either the local Channel Service Unit, or at the far end. Tl trunk card at 0106 0100 Trk 019 No power on the link; it has been removed is in red...
Page 448
Troubleshooting Table 7-l Fault Reports (continued) Alarm Code Message Action Required 155 Tl trunk card at 0106 01 00 Trk 019 There was a change in the network sync [cont’cf) was previous sync source in auto mode source. The link was the old sync source, and the system was in auto mode. Information only. Tl trunk card at 01 06 01 00 Trk 019 is reporting unstable link (phase error) The link is reporting phase errors. If this is the network sync source, a new source has been selected. Problem...
Page 449
Maintenance Log Messages Table 7-l Fault Reports (continued) Alarm Code Message Action Required 162 DIGlinecardfailedatOlO2 1102ext 123 Flood Call Processing received more than 125 EIA of EIA input Alarm Code = 162 input reports within 2 minutes while in the idle state; the data device was busied out. When the device is replaced, the data device will be unbusied. Check the equipment attached to the data device for a faulty EIA output. 163 DIG line card failed at 01 02 11 02 ext 123 A flood of...
Page 450
Troubleshooting Table 7-2 Alarm Log Reports Alarm Code Action Required Tot alarm went from No Alarm to MAJOR Use SHOW ALARMS command for more detailed see Alarm Reasons in Table 7-3 information. Also see the applicable entry in Table 7-3. Tot alarm went from MINOR to MAJOR see Use SHOW ALARMS command for more detailed Alarm Reasons in Table 7-3 information. Also see the applicable entry in Table 7-3. Tot alarm went from MAJOR to Use SHOW ALARMS command for more detailed CRITICAL see Alarm...