Home > Mitel > Communications System > Mitel Sx 200 Ml Pabx Lightware 16 Instructions Guide

Mitel Sx 200 Ml Pabx Lightware 16 Instructions Guide

Here you can view all the pages of manual Mitel Sx 200 Ml Pabx Lightware 16 Instructions Guide. The Mitel manuals for Communications System are available online for free. You can easily download all the documents as PDF.

Page 441

Maintenance Log Messages 
Table 7-l Fault Reports (continued) 
Alarm 
Code Message Action Required 
111 LS/GStrnkcardfai1edat020201 OOTrkl Can’t Verify the wiring from the trunk circuit to the 
seize trunk AlarmCode= 111 public network. Correct as required. Refer to 
CO tnmk card failed at 02 02 0100 Trk 01 Can’t the /r~s~a//a~~or~ /r~~orrrra~io/~ Practice. if this is 
seize trunk Alarm Code = 111 not the problem, suspect failure or bad wiring 
at the Central Off ice. 
E&M trunk card failed at 02 02 0100...

Page 442

Troubleshooting 
Table 7-l Fault Reports (continued) 
Alarm 
Code Message Action Required 
122 PFT sense passed at 00 00 08 00 The bay has been cut back to normal 
Bay has cut back Alarm Code = 122 operation. Verify that appropriate action was 
PFT sense passed at 03 00 00 00 taken to rectify the event which caused the 
Bay has cut back Alarm Code = 122 cut through. 
123 ONS card failed at 02 01 01 00 ext 123 GENERAL: The recording device attached to 
Recording dev failed 
Alarm Code = 123 the specified...

Page 443

Maintenance Log Messages 
Table 7-l Fault Reports (continued) 
Alarm 
Code Message Action Required 
129 ** anything ** failed at 00 00 00 00 Record this and watch for further occurrenc- 
Group-Link-Test not a proper member es. Perform a Verify Database operation and 
Alarm Code = 129 check for further occurrences of this Alarm 
* * anything * * failed at 00 00 00 00 Code. if system performance is degraded 
Group-Link-Test Invalid Group Link substantially, contact MITEL Field Service. 
Alarm Code = 129...

Page 444

Troubleshooting 
Table 7-l Fault Reports (continued) 
Jarm 
>ode Message Action Required 
132 Key-DB-test failed at 00 00 00 00 Key 1 is not programmed as an INTERCOM 
ont’d) ICM is not key 1 key - key I must be an INTERCOM key. 
Key-DB-test failed at 00 00 00 00 The INTERCOM key is not programmed as 
ICM not immed ring IMMEDIATE RING - must be so. 
Key-DB-test failed at 00 00 00 00 The DIRECTION for the INTERCOM key is 
ICM not in and out not programmed as In/Out - must be so. 
Key-DB-test failed at 00...

Page 445

Maintenance Log Messages 
Table 7-l Fault Reports (continued) 
Alarm 
Code Message Action Required 
141 Nil device failed at 00 00 00 00 The PMS system failed to respond to 20 
PMS is down Alarm Code = 141 consecutive queries from the PABX. Refer to 
PMS procedures. 
142 Nil device failed at 00 00 00 00 After failing to respond, the PMS system has 
PMS is up Alarm Code = 142 now responded to a PABX enquiry. 
143 Nil device failed at 00 00 00 00 The system attempted to send a message to 
PMS buffer is...

Page 446

Troubleshooting 
Table 7-l Fault Reports (continued) 
Alarm 
Code Message Action Required 
155 Tl trunk card at 01 06 01 00 Trk 019 The link has exceeded the specified 
(cont’d) has exceeded the service slip threshold threshold. A yellow alarm has been sent to 
the far end, and the link has been removed 
from service, and a new sync source selected. 
The RTS - Service Limit timer has been 
started. Refer to Ti Trunk troubleshooting 
procedures. 
Tl trunk card at 0106 01 00 Trk 019 
has exceeded the maint...

Page 447

Maintenance Log Messages 
Table 7-l Fault Reports (continued) 
Alarm 
Code Message Action Required 
155 Tl trunkcardatO1 0601 OOTrkO19 There is no synchronization detected on the 
(cont’d) is in red alarm condition due to loss of sync link; it has been removed from service. If this 
is the network sync source, a new source has 
been selected. Problem with either the local 
Channel Service Unit, or at the far end. 
Tl trunk card at 0106 0100 Trk 019 No power on the link; it has been removed 
is in red...

Page 448

Troubleshooting 
Table 7-l Fault Reports (continued) 
Alarm 
Code Message Action Required 
155 Tl trunk card at 0106 01 00 Trk 019 There was a change in the network sync 
[cont’cf) was previous sync source in auto mode source. The link was the old sync source, and 
the system was in auto mode. Information 
only. 
Tl trunk card at 01 06 01 00 Trk 019 
is reporting unstable link (phase error) The link is reporting phase errors. If this is the 
network sync source, a new source has been 
selected. Problem...

Page 449

Maintenance Log Messages 
Table 7-l Fault Reports (continued) 
Alarm 
Code Message Action Required 
162 DIGlinecardfailedatOlO2 1102ext 123 Flood Call Processing received more than 125 EIA 
of EIA input Alarm Code = 162 input reports within 2 minutes while in the idle 
state; the data device was busied out. When 
the device is replaced, the data device will be 
unbusied. Check the equipment attached to 
the data device for a faulty EIA output. 
163 DIG line card failed at 01 02 11 02 ext 123 A flood of...

Page 450

Troubleshooting 
Table 7-2 Alarm Log Reports 
Alarm Code 
Action Required 
Tot alarm went from No Alarm to MAJOR 
Use SHOW ALARMS command for more detailed 
see Alarm Reasons in Table 7-3 information. Also see the applicable entry in Table 7-3. 
Tot alarm went from MINOR to MAJOR see Use SHOW ALARMS command for more detailed 
Alarm Reasons in Table 7-3 information. Also see the applicable entry in Table 7-3. 
Tot alarm went from MAJOR to Use SHOW ALARMS command for more detailed 
CRITICAL see Alarm...
Start reading Mitel Sx 200 Ml Pabx Lightware 16 Instructions Guide

Related Manuals for Mitel Sx 200 Ml Pabx Lightware 16 Instructions Guide

All Mitel manuals