Home > Mitel > Communications System > Mitel Sx 200 Ml Pabx Lightware 16 Instructions Guide

Mitel Sx 200 Ml Pabx Lightware 16 Instructions Guide

Here you can view all the pages of manual Mitel Sx 200 Ml Pabx Lightware 16 Instructions Guide. The Mitel manuals for Communications System are available online for free. You can easily download all the documents as PDF.

Page 391

Peripheral Equipment Troubleshooting Procedures 
Table 3-24 DATASET 2103 LED indicators (continued) 
I Indicator Meaning 
POWER ON - Indicates that the Dataset has power, and is in sync with the 
corresponding Digital Line card. 
FLASHING - Indicates that the Dataset has power, but is not in sync with the 
corresponding Digital Line card. 
OFF - Indicates that the Dataset is not receiving power from the 9 Vat 
plug-in transformer. 
Page 2 of 2 
Note: See Figure 3-8. 
PHONE RS-232 
CONbECTOR 
POWER READY...

Page 392

Troubleshooting 
Table 3-25 DATASET 1103 Indicators 
Indicator 
DEVICE Meaning 
ON - Indicates that the attached device is connected to the Dataset unit, 
and is supplying DSR or DTR on pin 21 of the RS-232 connector. 
FLASHING - Indicates that the Dataset is transmitting data. 
OFF - Indicates that the device is not supplying DTR or DSR, or is not 
connected. 
READY 
POWER ON - Indicates that the Dataset is involved in an active call. 
FLASHING - Indicates that the Dataset is receiving data. 
OFF -...

Page 393

Peripheral Equipment Troubleshooting Procedures 
Step 
7. 
6. 
9. 
10. 
11. 
12. 
13. 
14. 
15. 
Table 3-26 DATASET 1103 / DATASET 2103 - DCE Mode Troubleshooting 
Procedures (continued) 
Possible Malfunction Source 
Incorrect modem switch settings or modem software set-up characteristics (if applicable). 
Modem requires reset - refer to manufacturer’s instructions. 
Faulty external equipment (modem). 
DATASET requires reset - disconnect, reconnect power cord. See Table 3-24 / Table 3-25. 
Bay Control...

Page 394

Troubleshooting 
ABUNK Data Module 
Table 3-27 outlines in descending order, the most likely items to cause malfunction. 
Table 3-27 M/L/NK Data Module Troubleshooting Procedures 
item Possible Malfunction Source 
1. Faulty connections between the data module and the cross-connect field. 
2. Faulty connections between the cross-connect field and the system. 
3. Faulty connections between the data module and the connecting device (terminal, tele 
phone set). 
4. Faulty CDE programming; likely forms: 
l...

Page 395

Peripheral Equipment Troubleshooting Procedures 
DEVICE ATTENTION 
TOP VIEW 
REAR VIEW 
AM/NK CHANNEL MMNK CHANNEL 
6 CONNECTOR A CONNECTOR 
RS-232 1 
CONNECTOR 
L F’OWER 
EECO95 
Figure 3-l 1 /WL/NK Data Module, Indicators and Connectors 
March 1997 Issue 1 Revision 0 3-29  

Page 396

Troubleshooting 
PABX 
AC ADAPTER 
IA232 TERMINAL 
M!hVK DATA MODULE 
Figure 3-12 /WUVK Data Module Configuration 
EEOZ42 
Table 3-28 /W//W Data Module LEDs 
Indicator Meaning 
DEVICE ON - indicates that the attached device is connected to the data module, 
(TO and is supplying DSR or DTR on pin 21 of the RS-232 connector. 
OFF - Indicates that the device is not supplying DTR or DSR, or is not 
connected. 
FLASHING - Indicates that the data module is transmitting data. 
READY ON - Indicates that the data...

Page 397

4 Subsystem 
Troubleshooting 
Procedures 
Main Control Card II 
4.1 The following paragraphs outline troubleshooting for the Main Control Card Il. 
Configuration 
The Main Control Card II consists of the following: 
l Main Control Card II 
l System ID module 
. Flash Memory card 
l Tl Clock. 
Main Control Card II Power-Up Tests 
The Main Control Card II power-up tests are run automatically upon operation of the 
RESET pushbutton located on the Main Control Card II front panel. The test results 
are...

Page 398

Troubleshooting 
FRONT PANEL ---!-!w 
FRONl 
(PANEI 
POWER SLIPPLY- 
PERIPHERAL- 
INTERFACE 
CARD 
BAY CONTROL - 
CARD 
MAIN CONTROL - REAR VIEW 
ll 
u ASSEMBLY 
ZTFM MAINTENANCE 
CONNECTOR 
-a ..e.s,.w 
I 
PORT FOR SYSTEM 
FAIL TRANSFER UNIT 
Figure 4-l SX-ZOO ML Cabinet 
4-2 Issue 1 Revision 0 March 1997  

Page 399

Subsystem Troubleshooting Procedures 
Table 4-l Main Cotdroi TroubleshooGng Summary 
Step Possible Malfundion Source for SX-ZOO ML Systems 
1. Main Control Card Ii requires a reset - press IX!ZE~pushbutton on the Main Control Card 
II front panel. 
2. Failure of initialization / power up tests - check for error codes on the Main Control Card II 
numeric displays - see Table 2-2. 
3. Faulty Bay Power Supply - refer to that procedure. 
4. Faulty Main Control Card Il. 
5. Faulty backplane cable connections....

Page 400

Troubleshooting 
Power-Up Sequence 
The Bay Control Card power-up sequence is described in the Genera/ MaMenaxe 
hformtion Practice. Table 4-2 summarizes the troubleshooting procedures for the 
Bay Control Card. 
Troubleshooting Procedures 
The following table outlines the most likely causes of Bay Control failure. 
Table 4-2 Digital Bay Control Troubleshooting Summary 
Step Possible Malfunction Source for the SX-200 ML System 
1. Bay Control Card requires a reset - power down bay, reseat card, and power...