Page 391
Peripheral Equipment Troubleshooting Procedures Table 3-24 DATASET 2103 LED indicators (continued) I Indicator Meaning POWER ON - Indicates that the Dataset has power, and is in sync with the corresponding Digital Line card. FLASHING - Indicates that the Dataset has power, but is not in sync with the corresponding Digital Line card. OFF - Indicates that the Dataset is not receiving power from the 9 Vat plug-in transformer. Page 2 of 2 Note: See Figure 3-8. PHONE RS-232 CONbECTOR POWER READY...
Page 392
Troubleshooting Table 3-25 DATASET 1103 Indicators Indicator DEVICE Meaning ON - Indicates that the attached device is connected to the Dataset unit, and is supplying DSR or DTR on pin 21 of the RS-232 connector. FLASHING - Indicates that the Dataset is transmitting data. OFF - Indicates that the device is not supplying DTR or DSR, or is not connected. READY POWER ON - Indicates that the Dataset is involved in an active call. FLASHING - Indicates that the Dataset is receiving data. OFF -...
Page 393
Peripheral Equipment Troubleshooting Procedures Step 7. 6. 9. 10. 11. 12. 13. 14. 15. Table 3-26 DATASET 1103 / DATASET 2103 - DCE Mode Troubleshooting Procedures (continued) Possible Malfunction Source Incorrect modem switch settings or modem software set-up characteristics (if applicable). Modem requires reset - refer to manufacturer’s instructions. Faulty external equipment (modem). DATASET requires reset - disconnect, reconnect power cord. See Table 3-24 / Table 3-25. Bay Control...
Page 394
Troubleshooting ABUNK Data Module Table 3-27 outlines in descending order, the most likely items to cause malfunction. Table 3-27 M/L/NK Data Module Troubleshooting Procedures item Possible Malfunction Source 1. Faulty connections between the data module and the cross-connect field. 2. Faulty connections between the cross-connect field and the system. 3. Faulty connections between the data module and the connecting device (terminal, tele phone set). 4. Faulty CDE programming; likely forms: l...
Page 395
Peripheral Equipment Troubleshooting Procedures DEVICE ATTENTION TOP VIEW REAR VIEW AM/NK CHANNEL MMNK CHANNEL 6 CONNECTOR A CONNECTOR RS-232 1 CONNECTOR L F’OWER EECO95 Figure 3-l 1 /WL/NK Data Module, Indicators and Connectors March 1997 Issue 1 Revision 0 3-29
Page 396
Troubleshooting PABX AC ADAPTER IA232 TERMINAL M!hVK DATA MODULE Figure 3-12 /WUVK Data Module Configuration EEOZ42 Table 3-28 /W//W Data Module LEDs Indicator Meaning DEVICE ON - indicates that the attached device is connected to the data module, (TO and is supplying DSR or DTR on pin 21 of the RS-232 connector. OFF - Indicates that the device is not supplying DTR or DSR, or is not connected. FLASHING - Indicates that the data module is transmitting data. READY ON - Indicates that the data...
Page 397
4 Subsystem Troubleshooting Procedures Main Control Card II 4.1 The following paragraphs outline troubleshooting for the Main Control Card Il. Configuration The Main Control Card II consists of the following: l Main Control Card II l System ID module . Flash Memory card l Tl Clock. Main Control Card II Power-Up Tests The Main Control Card II power-up tests are run automatically upon operation of the RESET pushbutton located on the Main Control Card II front panel. The test results are...
Page 398
Troubleshooting FRONT PANEL ---!-!w FRONl (PANEI POWER SLIPPLY- PERIPHERAL- INTERFACE CARD BAY CONTROL - CARD MAIN CONTROL - REAR VIEW ll u ASSEMBLY ZTFM MAINTENANCE CONNECTOR -a ..e.s,.w I PORT FOR SYSTEM FAIL TRANSFER UNIT Figure 4-l SX-ZOO ML Cabinet 4-2 Issue 1 Revision 0 March 1997
Page 399
Subsystem Troubleshooting Procedures Table 4-l Main Cotdroi TroubleshooGng Summary Step Possible Malfundion Source for SX-ZOO ML Systems 1. Main Control Card Ii requires a reset - press IX!ZE~pushbutton on the Main Control Card II front panel. 2. Failure of initialization / power up tests - check for error codes on the Main Control Card II numeric displays - see Table 2-2. 3. Faulty Bay Power Supply - refer to that procedure. 4. Faulty Main Control Card Il. 5. Faulty backplane cable connections....
Page 400
Troubleshooting Power-Up Sequence The Bay Control Card power-up sequence is described in the Genera/ MaMenaxe hformtion Practice. Table 4-2 summarizes the troubleshooting procedures for the Bay Control Card. Troubleshooting Procedures The following table outlines the most likely causes of Bay Control failure. Table 4-2 Digital Bay Control Troubleshooting Summary Step Possible Malfunction Source for the SX-200 ML System 1. Bay Control Card requires a reset - power down bay, reseat card, and power...