Mitel Sx 200 Ml Pabx Lightware 16 Instructions Guide
Here you can view all the pages of manual Mitel Sx 200 Ml Pabx Lightware 16 Instructions Guide. The Mitel manuals for Communications System are available online for free. You can easily download all the documents as PDF.
Page 501
Reports Level Functions Status - Entire Bay To obtain an equipment status report on an entire bay, press the following softkeys: SHOW STATUS BAY/SLOT/CCT (enter the required bay number, press the RETURN key, and enter only the RETURN key for the slot, circuit, and sub-circuit prompts) ENTER Status - Specific Card Slot To obtain an equipment status report on a specific card slot, press the following softkeys: SHOW STATUS BAY/SLOT/CCT (enter the required bay and slot numbers, pressing the...
Page 502
RS-232 Maintenance Terminal 3:98 PM l+JRN-97 alarm status = NO RLRRM > 86 SS CC SC SOFTWRRE-ID EX,TK TVPE 8G PWR MTSTRT SWSTRT HWSTRT 0080 - - dsP off avail - - 0100 - - Pcm tiff avail busy busy 0101 - - PCrn off avail free idle 0102 - P=m off avail free idle 0103 - p=m off auail free idle 010q - PC off avail free idle m 0105 - Pcm off avail free idle 0106 - - Pcm off avail free idle 0107 - - Pcm off avail free idle DEUICE STflTUS < l- 6-MT-DWR 2- 3- q- 5-CRNCEL 7-MT-DWR-HEH...
Page 503
Reports Level Functions Table 5-3 summarizes the terms used in the equipment status report: Table 5-3 Terms Used In the Equipment Status Report Term Meaning BB The bay in which the device is located ss The card slot in which the device is located cc The circuit number of the device SC The sub-circuit number of the device (where applicable) SOFTWARE-ID Type of device installed and its software identification number ( SWID ) EX/l-K The extension or trunk number of the device (where applicable);...
Page 504
RS-232 Maintenance Terminal Table 5-3 Terms Used In the Equipment Status Report (continued) Term SWSTAT Meaning bsout - busied-out by maintenance - failed diagnostic test at least twice, or busied-out by maintenance user flty0 faulty with no passes fltyi faulty with one pass flty2 faulty with two passes flty3 faulty with three passes flty4 faulty with four passes flty5 faulty with five passes flty6 faulty with six passes The current call processing (CP) software status; for lines and trunks,...
Page 505
Reports Level Functions Table 5-3 Terms Used In the Equipment Status Report (continued) Term Meaning HWSTA T rngbk - ringback rngng - ringing t-s232 - data station is establishing RS-232 protocol stowd - stowed (hard or call hold) suspd - suspended talkg -talking tkd - trunk dial wdtrx - data station waiting for dtrx response wfjct - waiting for call resources (receiver, channel) wflin - waiting for line The current call processing (CP) software status, for receivers ; one of the following:...
Page 506
RS-232 Maintenance Terminal Show Status - SWID This operation enables a user to show software status by selecting a device type. To obtain an equipment status report on a software identifier, press the following softkeys: SHOW STATUS SWID (press one of the softkeys shown in Table 5-4) ENTER The system outputs the equipment status data in the applications area of the screen. Where the data requires more space than is available on the screen, the user is prompted to request more datavia the...
Page 507
Reports Level Functions Device Status Reports 5.5 Device status reports display call processing information for devices (sets, stations, consoles, trunks, receivers, etc.) that are programmed into the system. A device status repot-t displays the call processing work area (CP-DWA) of a device. Figure 5-3 shows an example of a CP-DWA of a tie trunk. 3:28 PH l+JRN-97 alarm status = NO RLRRM I 88 SS CC SC SOFTWRRE-ID EX/TK TYPE 8G PWR MTSTRT SWSTRT HWSTRT 0060 - 0100 - 0101 - 0102 - 0103 - 010q...
Page 508
RS-232 Maintenance Terminal Monitor Ti Trunk Activity 5.6 The user can monitor the activity on the ST bus to the Ti Trunk Module by displaying a Monitor Ti Trunk Activity report on the maintenance terminal screen. A Monitor Ti Trunk Activity report provides data for the DSTi, DSTo, CSTi, and CSTo buses. This feature also allows the user to perform the following functions: l Send a yellow alarm to the receiving end l Put the Tl Trunk card into analog loopback mode l Manually select the...
Page 509
Reports Level Functions To display a Monitor Tl Trunk Activity report, press the following softkeys when in maintenance mode: REPORTS SHOW STATUS BAY/SLOT/CIRCUIT (enter PLID.....) LINK-STATUS (This softkey only appears if the affected circuit is a Ti circuit) TRUNK-NUM Enter the circuit location on the Ti Trunk Card (24 Tl circuits per Ti Trunk Card) ENTER Data from the DSTi, DSTo, CSTi, and CSTo buses of the selected trunk is presented on the screen. To send test data, press the following...
Page 510
RS-232 Maintenance Terminal Table 5-5 provides definitions for the softkey commands that you can enter from the maintenance terminal to test the Ti link. Table 5-5 Softkey Definitions Softkey TRUNK-NUM CANCEL YELLOW RETURN MANUAL AUTO SEND TxPadz RxPad Tx/AB-00 Tx/AB-01 Tx/AB-10 Tx/AB-11 LOOPBACK - INTERNAL LOOPBACK - EXTERNAL LOOPBACK-D UPDATE Definition Prompts for target trunk. Defaults to 01. Valid is 01-24, Goes back to REPORTS LEVEL form. The default settings for ail...