Page 511
Reports Level Functions The information in Table 5-6 is displayed for information only; it cannot be altered from the terminal. Table 5-6 Definition Of Maintenance Terminal Display Display Meaning DSTi Data ST bus input (32 channels 24 active). DSTo Data ST bus Output (32 channels 24 active). CSTi Control ST bus Input (32 channels 25 active). CSTo Control ST bus Output (32 channels 2.5 active). SYNC SYNC indicates whether there is synchronization to the RECEIVED DSl link, SLIP This bit changes...
Page 512
RS-232 Maintenance Terminal 1 I Table 5-6 Definition Of Maintenance Terminal Display (continued) Display Meaning TxPD The per channel transmit attenuation control bits. RxA, RxB RxA and RxB are the receive A and B bits used for monitoring channels on the DSl link. 1 RxPD 1 The per channel receive attenuation control bits. I LPBK LPBK indicates whether any loopbacks have been activated: no -there are none Ext - External loopback has been activated for the card lnt - Internal loopback has been...
Page 513
Reports Level Functions Data Fault Analysis Procedures ’ 5.7 Generic information and procedures for analyzing datasets and data-related problems is provided here; refer to it for troubleshooting problems before referring to specific data device troubleshooting charts. Table 5-7 Possible Causes Of Data-related Errors ERROR POSSIBLE CAUSE CALL STATE DATASET CABLI DX DLC DTE / DCE NG CRCERR ANY Yes Yes Yes Yes No (DNICIHDLC) (DNlC/HDLC) RESETS ANY Yes Yes Yes Yes Yes LINK CALL Yes Yes Yes Yes No...
Page 514
RS-232 Maintenance Terminal 5-20 Link Aborts: A link abort occurs when the dataset, after sending a SABM 8 times, cannot get a valid response from the far end. Thus, a link abort often follows a link reset (specifically when the link reset happened because of many transmission line errors, set unplugged, or circuit switch path broken). Link aborts can also occur just after the dataset is sent to the B-channel. The dataset will send up to 64 SABMs in an attempt to achieve communication; if it does...
Page 515
Reports Level Functions Power Up Self Test Causing the Dataset to be Busied Out: If a dataset fails its power up self test, it will be busied out. Maintenance logs will have two log entries: the busied out log and the power up self test failure reason. If a new dataset is installed that passes the power up self test, the device will be returned to service, without an installer using a maintenance command. Error Reports Show Errors 5.8 The Error Reports provide the maintenance user with an...
Page 516
RS-232 Maintenance Terminal Digital Set Errors m ~HIIU ERRIIR~ DIG1 T FIL-SET s l- 2- 3- 4- 5- CWlCEL 6- 7- 8- 9- 0- Figure 5-5 Example of Digital Set Error Report Explanation of error types: No Sync: A synchronization signal is sent between the digital circuit and the set. The digital circuit monitors the physical line for the presence of this signal. Synchronization is lost when a set is unplugged or when a line is very noisy (external interference or bad connection). A loss of...
Page 517
Reports Level Functions Retransmits: The retransmit counter increments each timeadigital circuit has to resend just sent information to a set. If the set has not responded to having received the just sent information, the circuit resends. This problem can be caused by: - a noisy line - bad set - bad circuit - software error (protocol violation). In most cases, a set will have no retransmits in a 24-hour period; however this counter can be influenced by the amount of traffic to the set. The more...
Page 518
RS-232 Maintenance Terminal Explanation of HDLC Link Error types: HDLC Link errors are explained following: ERROR BAY TO MC MC TO BAY Error Rate Expected TX-ERR Transmitter underrun. Transmitter underrun. none RX-ERR Undefined error. Undefined error. none OVRFLW Bay HDLC receiver fifo overflowed. Main HDLC receiver fifo none overflowed, ABORTS Bay received HDLC ABORT Main received HDLC ABORT see note 1 sequence from main. sequence from main. ODDPKT Bay received packet with odd Main received...
Page 519
Reports Level Functions Explanation of error types: No Sync: A synchronization signal is sent between a digital circuit and a console. The digital circuit monitors the physical line for the presence of this signal. Synchronization is lost when a console is unplugged or when a line is very noisy (external interference or bad connection). A loss of synchronization increments the ‘no sync’ counter; however, maintenance reports are updated only after 25 occurrences. In normal operation, this counter...
Page 520
RS-232 Maintenance Terminal DATASET Errors 1:16 PH 14-JfiH-97 alam status q tW MWl PLIR EXT.# FRILRS RENIRTS CRCERR RESETS PRRITY RURFLU tlWftiC 1 8 1 2 13888 0 0 El 0 0 0 1 I SHMI ERRURS DRTRSETS I l- 2- 3- 4- 5-CRtlCEl 6- 7- 8- 9- 0- Figure 5-8 Example of DATASET Errw Statistics Report Explanation of error types: FAIL%: The dataset sends flags requesting communication but does not receive acknowledgment from the Digital Line Card; the HDLC on the DLC is time-shared with up to 12...