Page 311
Data Features lHeralds and call progress messages are only displayed if programmed; see DATA TRANSCEIVER (DTRX). ProgrammingAssign the originating dataset a DTE Profile number in CDE Form 12 (Data As- signment). Program the Data Circuit Descriptor Options in CDE Form 11 (Data Circuit Des-criptors) subform. Program the DTE Profile in CDE Form 29 (DTE Profile). OperationDTRX operation is described below. DTRX Originate lPress the RETURN or ENTER key on the DTE keyboard. (Keyboard Origina- tion must be...
Page 312
Features Description tors). It must remain off for longer than the duration of the DTR OFF Dis- connect timer duration. OR lPress the BREAK key (if enabled). OR lPress the PBX Attention Character key (if programmed). OR lPress the ATTENTION key on the dataset. ORl Press the DATA CALL ORIGINATE/ATTENTION key on the Digital SUPERSET telephone. To disconnect from DTRX and return to idle state: l At the * prompt, enter BYE or CCTRL E>. “Goodbye” message is dis- played. lWhile connected to DTRX, wait for the...
Page 313
Data FeaturesConditions None ProgrammingNone OperationAt the * prompt, type HELP and the topic name, followed by . DTRX responds with the required information and returns to the * prompt. If the topic is not known, just type HELP followed by . DTRX responds with a list of topics and the ? prompt. Type,the required topic name, followed by .:To exit from Help, type at the ? prompt. DTRX Ho&e Description6.19 A dataset can be programmed to connect automatically to a predeter- mined destination when a user...
Page 314
Features Description Table 6-1 DTRX Messages(continued) Message DO201 Call Failure-BusyMeaning The destination is busy and queuing is not en- abled. The user is then returned to the DTRX *prompt. _ DO203 Call Failure - Invalid Number, Check Direc-The directory n’umber does not exist. The user istoryreturned to the DTRX * prompt. DO204 Call Failure -Out of Order, Call Communi-The destination data device has been busied out. cations DepartmentThis can indicate a fault in the destination data device.DO205...
Page 315
Data Features Table 6-1 DTRX Messages(continued) Message 503 Facility -Call is QueuedMeanmg The destination is busy and queuing is enabled. The “Queue Position” message follows if the des- tination is a dataset. The DTRX is dropped until it is needed to display the call progress messages, orthe next queue:position. When the destination device becomes free, the “Ringing”and “Con- nected” messages follow. 57204 Facility- Queue Position nn .This message occurs after every system clock min- ute. It...
Page 316
Features Description Table 6-I DTRX Messages (conti’nued) MessageMeaning GO1 10 Information - Call Disconnected By Desti-The destination data station disconnected the nationcall. GO201 System Error-System Busy, Try Again Lat-There are no free DTRX work areas in system ermemory. GO301 User Error - User Has been inactive for tooDTRX or data call dropped due to inactivity timer Longexpiry. If in DTRX, “Goodbye” message follows. GO302 User Error - Unrecognized Command,The system could not understand...
Page 317
Data Features Modem Pooling is not available with Generic 1002.Conditions The following conditions apply to this feature: 0COS Option 217 (Direct to ARS) is ignored for outgoing data calls.l If the originator does not dial a specific Modem Pool Hunt Group access code, a pooled modem is selected from the default modem pool hunt group, if programmed.l On incoming or internal calls, the system prints TRUNK SMDR reports for the trunk and DATA SMDR reports for the pooled modem if they are en- abled in the...
Page 318
Features Description lBay/Slot/Circuit location of its ONS (or OPS) Line (system-supplied), lData Circuit Descriptor Number (CDN) that applies to its dataset, l Bay/Slot/Circuit location of its dataset’s Digital Line, l extension numberl tenant (default is ‘l), l DTE Profile Number (optional), lClass of Service (COS) (default is 1) and Class of Restriction (COR) (default is l), 0 mode: Answer, Originate, or Both (default is Both). l autodial capability: Auto dial or Non Auto dial (default is Non Auto...
Page 319
Data Features Incoming DISA Trunk Modem Call lFrom the Public Network, using a DTMF telephone, dial the DISA tele- phone number. The PABX answers and returns dial tone. lDial the DISA Access Code (normal DISA trunk) or Account Code (if a Spe- cial DISA trunk). Once access is allowed, the system returns dial tone. 0 Dial: - Data Station or Data Hunt Group access code (where default modem pool hunt group is selected, if programmed) or, - Modem Pool Hunt Group access code for DTRX access - Modem Pool Hunt...
Page 320
Features Description - Data Station or Data Hunt Group access code where default modem pool hunt group is selected, if programmed - Modem Pool Hunt Group access code for DTRX access - Modem Pool Hunt Group access code plus Data Station or Data Hunt Group access code lWhen answer tone is heard, the modem pooling call is established; put the modem on line lIf DTRX access is used, enter CALL followed by the destination data num- ber or name at the DTRX prompt. . Incoming Direct-In-Line (DIL) Modem Calll...