Page 301
Data Features lPress the HANG UP (or New Call) softkey. The SUPERSETtelephone is now available for voice calls. In this way, it is possi- ble to have simultaneous voice and data calls. The data call terminates whenthe modem goes on-hook. To make an alternating voice/data call: lAt the SUPERSETtelephone, establish a normal voice call with the destina- tion set. lAt both telephones, press the SWAP (Trade Calls) softkey to switch to data communication and put the modem on-line. lWhen data communication is...
Page 302
Features Description Automatic Data Route Selection (ADRS) DescriptionConditions None ProgrammingTrunks should be grouped into Trunk Groups according to the maximum data rate they can support. For more information, refer to Practice 9109-094-220-NA, Automatic Route Selection and Toll Control. Operation6.8 Outgoing trunk Data calls are processed by the same Automatic Route Se- lection (ARS) system as voice trunk calls; see AUTOMATIC ROUTE SELECTION. Automatic Data Route Selection is not available with...
Page 303
Data Features Set System Option 55, Account Code Length in CDE Form 04 (System Options/ System Timers) to a value between 4 and 12, or to VARIABLE. To require account code entry on internal ADL or DTRX data calls, enable COS Option 326 (Account Code Forced Entry -Data Internal Calls) for the originat- i ng dataset. To require account code entry for incoming or internal modem pooling calls, enable COS Option 326 (Account Code Forced Entry - Data Internal Calls) in the Pooled Modem’s COS. Enable one of...
Page 304
Features Description CALL destination ACCOUNT account code DISA (Incoming) When the PABX answers: lDial the DISA access code -the system returns dial tone. lDial the Account Code access code. 0 Dial the Account Code. l Dial the destination number. Special DlSA (Incoming) When the PABX answers: lEnter the Account Code - if it is valid, the PABX returns dial tone. l Dial the destination number. Incoming Tie Trunk or Internal Modem Pooling Caller l Dial the Account Code access code. l Dial the Account...
Page 305
Data Features lThe system can support a total of 50 hunt groups; a hunt group may have a maximum of 50 members. ProgrammingEnter the dataset extension numbers into CDE Form 17 (Hunt Groups). When the first dataset is entered, the system sets the hunt group type to Data. The system then accepts only datasets as subsequent entries. Specify TERMINAL or CIRCULAR hunting as desired. Program an access code for the Hunt Group. If desired, program a name for the Data Hunt Group. This is useful for DTRX calls....
Page 306
Features DescriptionConditions Programming OperationFor details on the the SUPERCOAfSOLE 7000” printer port, see DIRECTED IN- PUT/OUTPUT. For details on data circuit descriptor options, refer to Practice 9109-094-210-NA, Customer Data Entry (CDE). Refer to Practice 9109-094-125-NA, Circuit Card Descriptions, for a descrip- tion of the Digital Line Card. Refer to the following Practices: l 9141-753-503-NA, DATASET 1100 Series, and l 9141-753-SO&NA, DATASET 2100 Series. Program a Digital Line Card card...
Page 307
Data Features trunk call SMDR record and includes “Data Call Indicator”, “Type of Data Call” and “Reason for Disconnect” fields. A dash (-) rather than a slash (/) sep- arator between the month and day gives a distinctive appearance to the printed data records, and allows a call costing device to maintain separate totals for data and voice calls. The “External Data Call Indicator” field shows EX if the data call used a pooled modem and a trunk. The “Associated SMDR Record Indicator” field shows an...
Page 308
Features DescriptionADL from Industry-standard Telephone, SUPH?SET3 and SUPERSET3DNTelephones The telephone calls a busy data device: lthe telephone receives Special Busy tone for 2 seconds, then the telephone receives Busy tone while it is queued.ADL from SUPERSET 4 Telephones The set calls a busy data device: lThe set receives Special Busy tone. The display shows “BUSY”. The CAMP ON softkey appears. lPress the CAMP ON softkey within 10 seconds. The display shows “CAMP- ING 0N”while the set is...
Page 309
Data FeaturesConditions The following conditions apply to this feature: lA dataset connects each Data Terminal (DTE) to the system on a DNIC cir- cuit. oThe DTE connected to the dataset must be an ASCII data device using an RS-232C interface. lAll DTRX commands (except ACCOUNT) may be abbreviated to its mini- mum unique character string. lTo connect to a Data Transceiver, a data device must have a DTE Profile number programmed in CDE Form 12 (Data Assignment). ProgrammingThe DTRX feature is associated...
Page 310
Features Description sage category is not displayed. The text also displays a user action if appropri- ate (e.g. System Busy, Please Wait). If the Message Code option is also enabled, the complete message is displayed. Enable or disable COS 904 (DTRX Complete Message Text) as desired. This op- tion displays the message code, the message category, and the text (e.g.DO207 Call Failure - Destination Not Ready). OperationSee DTRX CALL ORIGINATE/DISCONNECT. DTRX Call by Name Description6.16 This feature...