Page 181

System FeaturesTable 3-7 E&M Trunk Card Hardware Options
Trunk Hardware Option
Inhibit Automatic Supervision
No Seize Alarm
No Release Alarm
Toll Office
Is this a CO
DTMF
impedance (600 Ohms or Complex)
Remote End is a Satellite
Remote End is a Satellite with OPS LinesDictation Trunk
Page 2 of 2 

Page 182

Features Description
Table 3-8 2-CCT DID/Tie and Tie DISATrunk Hardware Option
IReverse to Idle
1
Far-End Gives Answer Supervision
Inhibit Automatic Supervision
No Seize Alarm
No Release Alarm
Toll Office
I .
is this a COIImpedance (600 Ohms or Complex)
Remote End is a Satellite
Remote End is a Satellite with OPS Lines
Page 1 of 1 
1Table 3-9 
6-CCT DID
Trunk Hardware Option
Reverse to Idle
Far-End Gives Answer Supervision
Inhibit Automatic Supervision
No Seize Alarm
No Release Alarm
Toll Office
Is this...

Page 183

System FeaturesTable 3-10 
Tl E&M and Tl E&M DISATrunk Hardware OptionTable 3-9 
C-CCT DID
(continued)
Trunk Hardware 
Option
Release Acknowledge Timer (2 to 120 seconds)
Guard Timer (ZOO -1000 ms) x (100 ms increments)
Start Type (Immed, Wink, Delay)
Debounce Timer (20 to 150 ms) x (10 ms increments)
Wink Timer (150 to 300 ms) x (50 ms increments)
Remote End is a Satellite
Remote End is a Satellite with OPS LinesPage 2 of 2
Reverse to Idle
Far-End Gives Answer Supervision
Inhibit Automatic Supervision...

Page 184

Features DescriptionTable 3-10 
Tl E&M and Tl E&M DISA(continued)
Trunk Hardware Option
Outgoing Start Type (Immed, Wink, Delay or Delay Integ)Digit Outpulsing Ratio 
(60/40, 30/20, 66/33)
Outpulse Delay Timer (100 to 2000 ms) (100 ms inc)
Flash Timer (200 to 700 
ms) (100 ms inc)
Interdigit Timer (300 to 800 
ms) (100 ms inc)
Wait for Delay Timer (300 to 5000 
ms) (100 ms inc)
Remote end is a satellite
Remote end is a satellite with OPS LinesPage 2 of 2 
1Table 3-l 1 
Tl DID/Tie and Tl Tie DISATrunk...

Page 185

System FeaturesTable 3-l 
I Tl DID/Tie and Tl Tie DISA(continued)
Trunk Hardware Option
Wink Timer (150 to 300 ms) (50 ms inc)
Outgoing Start Type (Immed, Wink, Delay or Delay Integ)
Digit Outpulsing Ratio 
(60/40, 30/20, 66/33)
Outpulse Delay Timer (100 to 2000 ms) (100 ms inc)
Flash Timer (200 to 700 ms) (100 ms inc)
Interdigit Timer (300 to 800 ms) (100 ms inc)
Wait for Delay Timer (300 to 5000 ms) (100 ms inc)
Remote End is a Satellite
Remote End is a Satellite With OPS Lines
Page 2 of 2
Table 3-12...

Page 186

Features DescriptionTable 3-12 
Tl LS/GS and Tl CO DISA(continued)
Trunk Hardware Option
1 Ringing Debounce Timer (5 to 12 seconds)I
Seize Timer (10 to 60 s) (10 s increments)
Flash Timer (200 to 700 ms) (100 ms inc)
Interdigit Timer (300 to 800 ms) (100 ms inc)
IPage 2 of 2 1
ProgrammingSelect Trunk Circuit Descriptors in CDE Form 13 (Trunk Circuit Descriptors). If
the system is to provide pseudo answer supervision, set an appropriate time
for the time-out period via System Option 43 (Pseudo Answer...

Page 187

System Features
Guard Timer: This defines how long the system will wait after releasing the
trunk before seizing it again for an outgoing call.
Ignore Line Reversal During Seizure: If selected, line reversal is not recog-
nized as an incoming seizure.
Ignore Remote Disconnect: If selected, release signals from the far-end are
ignored. If not selected, release signals cause disconnection of the call.
Impedance: “600” should be selected if the trunk is to be connected to a carri-
er facility, or the cable...

Page 188

Features Description
Remote End is a Satellite: Select if the trunk is to terminate at a satellitePABX. Refer to Practice 
9109-094-180-NA, Engineering Information for de-
tails of loss/gain.
Remote End is a Satellite with OPS lines: Select if the trunk is to terminate at a
satellite PABX with OPS lines. Refer to Practice 
9109-094-l80-NA, Engineer-
ing Information for details of loss/gain.
Reverse to Idle: In some central offices, upon seizure, the CO reverses the po-
larity on the trunk. When the call...

Page 189

System Features
Dial tone detection, without the alarm, can also occur in the middle of trunk
dialing; see AUTOMATIC ROUTE SELECTION.Conditions
The following conditions apply to this feature:
lEnabling Limited Wait For Dial Tone disables the No Dial Tone Alarm.
lThe no dial tone alarm time is set at 10 seconds.
lWhen the trunk is removed from service, the party dialing on the trunk
-ends dialing and is given busy tone.
l50 simultaneous dial tone detections can occur in the system at any one-
time.
lIf...

Page 190

Features Description
lDirect Trunk Select and Private Trunk line trunks must be in trunk groups
before outgoing calls can be made on the trunk lines.
lDirect Trunk Select and Private Trunk Line trunks are never hunted from atrunk group.
lA trunk is selected from a trunk group if it is idle, if it is not being seized by
another party, if a no seize alarm is not pending and if the caller and the
trunk can connect together.
lA trunk does not need to be in a trunk group to originate a call.
lTrunk groups can...
Start reading Mitel SX 200 DIGITAL Pabx General Descriptions Manual