SECTION MlTL8350-048-l OO-NA 
terminal. Upon power on, the SAC monitors the RS-232 port for 7 
seconds. During this time period, the unit expects to receive an ini- 
tialize command at a rate of 1200 Baud. This command consists of the 
two characters ‘AA’ and must be entered from the keyboard (in upper 
case only). 
2.17 If, after 7 seconds, the initialize command is not received, the 
SAC will check its internal memory for the programmed Baud 
rate (1200 Baud by default) and switch to that Baud rate....

Page 302

SECTION MITL8350-048-l OO-NA 
--- THIS PAGE INTENTIONALLY LEFT BLANK --- 
Page 8  

Page 303

SECTION lVlITL8350-048-l OO-NA 
3. SPECIFICATIONS 
HARDWARE 
3.01 
Table 3-1 lists all of the hardware specifications for the SMarT- 
ltm Security Access Controller (SAC). These specifications apply 
to all models of the Controller (4-, 2-, and l-line units) unless other- 
wise noted. 
Table 3-1, SMarT-1’” Hardware Specifications 
SPECIFICATION 
FCC RINGER EQUIVALENCE 
IDLE LINE, LOOP START 
RINGER IMPEDANCE: 15-60 Hz, 70-11OV 
20-3500 Hz, IOV 
RINGING SENSITIVITY: 15-60 Hz 
LEAKAGE: Tip to Ring, 1OOV...

Page 304

SECTIQN MITL8350-048-l OO-NA 
Table 3-l (Cont’d), SMarT-1’” Hardware Specifications 
SPECIFICATION 
DIAL TONE 
CO 
SIDE FEED: Gain 300 Hz 
INTERNAL FEED: 350 Hz 
DTMF RECEIVER 
LEVEL 
LEVEL DIFFERENCE 
FREQ: To receive 
To not receive 
DURATION 
TIME BETWEEN TONES 
ROTARY RECEIVER 
MAKE IMPEDANCE 
MAKE DURATION 
BREAK IMPEDANCE 
BREAK DURATION 
RATE 
DTMF SENDER 
LEVEL 
FREQUENCY 
DURATION (Programmable) 
ROTARY SENDER 
TIMING (Programmable) 
TIMING (At 60/40): Make 
Break 
RATE (At 60/40) 
INTERDIGIT...

Page 305

SECTION MlTL8350-048-l OO-NA 
PARAMETER 
BAUD RATE: 
PARITY: 
BITS PER CHARACTER: 
BIT EIGHT SENSE: 
MODE: 
OPERATION: 
RS-232 PORT 
3.02 
Table 3-2 below contains the specifications for the SMarT-I’” 
Security Access Controller RS-232 Auxiliary Port. This port may 
be used for programming or for SMDR Output. 
Table 3-2, RS-232 Port Specifications 
SPECIFICATION 
300 
to 9600 Baud programmable; default 
= 1200 Baud 
None 
Eight bits per character with one stop 
bit. 
Space 
On line. 
Full duplex mode....

Page 306

SECTION MlTL8350-048-IOO-NA 
3.05 
The specifications in the Tables above are subject to change 
without notice. The inclusion of ‘n/a’ for a specific parameter 
means that the specification is not available at the time of this pub- 
lication. It will be added at a later date. 
Page 12  

Page 307

SECTION MITL8350-048-l OO-NA 
4. UNPACKING, INSTALLATION AND ORDERING INFORMATION 
SHIPPING AND RECEIVING 
4.01 
The SMarT-1’” Security Access Controller is shipped in a single 
carton that contains the Controller, the Power Supply, a Wall 
Mounting Bracket, four RJ31XKA31A Cables and appropriate docu- 
mentation. All of these items are protected within the carton by styro- 
foam inserts. 
Note: Some production units do not require the wall mounting 
brackets since these units are mounted to a wall by...

Page 308

SECTION MITL8350-048-l OO-NA 
RJ31WCA3lA 
CABLES 
 
DOCUMENl 
-ATlOh 
I 
--I 
DIALER 
Figure 4-1, Equipment Unpacking and Repacking . 
H.AI’ DETAIL 
Page 14  

Page 309

SECTION MlTL8850-048-l OO-NA 
SINGLE UNIT 
CARTON 
‘ 
 
/-- 
 
/-- 
 /- 
 _-- 
\__-- 
 
/ 
MULTI-UNIT 
CARTON 
Figure 4-2, Multi-Unit Packing and Repacking 
Page 15  

Page 310

SECTION MITL8350-048-l OO-NA 
4.07 
The SAC will operate within a 0-55°C temperature and a 0435% 
humidity range. 
POWER REQUIREMENTS 
4.08 
The customer must provide a single phase power receptacle 
with the following recommendations: .: :: 
115V, 60Hz fused and capable of delivering 350mA per unit 
installed. 
The power receptacle should be wired and fused independently 
from all other receptacles that are not controller related. 
A warning tag should be attached to circuit breaker type fuses 
to...