SECTION MlTL8350-048-l OO-NA 
> [604424F42BBl 
> 
7.45 
After entering this command as shown above, and after exiting 
the programming mode, access to programming can only be 
gained by entering ‘BOB’ on the terminal keyboard as shown 
below: 
[BOB] 
REV xx-xx ENTERING PROG. MODE 
> 
where xx-xx is the revision of the software that is resident in the 
Controller. 
Note: The password ‘BOB’ is entered on the keyboard, but is not 
displayed on the terminal for security reasons. 
Table 7-3, System Wide...

Page 342

SECTION MITL8350-048-IOO-NA 
Table 7-3 (Cont’d), System Wide Operational Parameters 
ENTER DEFAULT DESCRIPTION 
009t 2 
Selection of Print Format for Call Detail Recording Output, where ‘t’ 
equals: 
0 = Call Detail Recording Disabled. 
1 = MITEL Format selected. 
2 = SMarT Format selected. 
01ot 9 Route to Monitor, where ‘t’ equals: 
0 thru 3 = Primary Routes 1,2,3, and 4. 
4 thru 7 = Alternate Routes 5,6,7, and 8. 
8 = Monitor routed calls only. 
9 = All Routes (default). 
7.46 
OOlt - Re-order Tone....

Page 343

SECTION MITL8350-048-1 OB-NA 
=:-_11 ‘I’l”~~~ii~~~~‘~ ~0 NOT set the Baud Rate to a value which is not 
supported by the device that is connected to the RS- 
232 Computer Port. Doing so will prevent any further 
programming of any kind, including any efforts to 
change the value of this parameter in any way. If this is 
done, the only way to do any further programming of 
any kind is to follow the initialization procedure de- 
tailed in paragraph 6.06 (page 301, which will delete all 
programming done to...

Page 344

SECTION MITL8350-048-l OO-NA 
table. The letter ‘x’ preceding the command digits indicates that a trunk 
select number be entered to choose the particular trunk to be pro- 
grammed for the command. These numbers equate to: 
1 = program only Trunk 1 
2 = program only Trunk 2 
3 = program only Trunk 3 
4 = program only Trunk 4 
5 = program all trunks simultaneously 
7.53 For example, if it is desired to program ALL Trunks simulta- 
neously for a Loop Start Central Office using Rotary dial, the 
programmer...

Page 345

SECTION MITL8350-048-1 OO-NA 
Table 7-4 (Cont’d), Trunk Related Parameters 
ENTER DEFAULT DESCRIPTION 
x05t 5 
Time period between Line Drop and Reseizure, where t equals: 
0 = 500ms 5 = 1250ms 
1 = 650ms 6 = 1400ms 
2 = 800ms 7 
= 1550ms 
3 = 950ms 8 = 1700ms 
4 = 1100ms 9 = 1850ms 
x27t 1 Call Answer Timer, where if t = 0, The Controller is ‘OFF’ and all 
SAC activity is disabled. Calls into the protected Modem will not be 
processed or interfered with. Other values for t are: 
1 = 3 seconds 9 = 27...

Page 346

SECTION MITL8350-048-l OO-NA 
Table 7-4 (Cont’d), Trunk Related Parameters 
ENTER DEFAULT DESCRIPTION 
x35t 0 
Progress Tones (Beeps), where t equals: 
Request Request 
t Password Callback Nr. 
(1 Tone) (2 Tones) 
0 ON ON 
. 
1 
ON ON 
2 
ON OFF 
3 ON OFF 
4 OFF ON 
5 OFF ON 
6 OFF OFF 
7 
OFF OFF 
Hang 
UP 
(3 Tones) 
ON 
OFF 
ON 
OFF 
ON 
OFF 
ON 
OFF 
x36t 1 Time to wait after valid password determination before processing 
of the callback (drop and reseize parameter x05t) is initiated, where 
t...

Page 347

SECTION MlTL8350-048-lOO-NA 
> r50131 
> 
7.57 x02t - 
This command will select the DTMF Dialing rate if com- 
mand xOOt above were programmed for DTMF dialout. The rate 
ranges from 40 to 130 ms in 10 ms steps. 
60 ms is the default 
selection for this command. Selection is done by entering a number 
from 0 through 9 for the letter t in the command line. For example, if 
Trunk 3 were to use DTMF dialing at a rate of 100 ms, the command 
would be entered as: 
> t30261 
> 
7.58 
x05t - This command...

Page 348

SECTION MITL8350-048-l OO-NA 
timer. The default for this command is 8/16 seconds (i.e., the Controller 
will wait for 8 seconds for the caller to enter a valid password before 
timing out and terminating the call and 16 seconds for the caller to 
enter his callback number (if used). For example, 
if it is desired to have 
the Controller to wait 16 seconds for password 
entry by the caller on 
Trunk 2, the command would be entered as: 
> 122831 
> 
7.61 The entry of the 
period for waiting 
7.62 
x29t -...

Page 349

SECTION MlTL8350-048-lOO-NA 
x05t). The default for this command is ‘0’ for 10 seconds. The range of 
the timer is from 10 to 150 seconds as selected by the number 1 to 9 
or the letter A to F that replaces ‘t’. For example, if it is desired to 
program Trunk 1 to wait for 150 seconds prior to initiating callback, 
the command line would be entered as: 
> Il36Fl 
> 
Non-Controller Pertinent Parameters 
7.66 Table 7-5 below lists the Trunk related programming param- 
eters that are non-Controller...

Page 350

SECTIQN MITL8350-048-IOO-NA 
Table 7-5, Non-Controller Pertinent Parameters 
ENTER DEFAULT DESCRIPTION 
x07t 3 Time to wait for Tip Ground on Ground Start Try (Ground Start 
Timeout in seconds), where t equals number of seconds to wait 
until timeout. 
x14t 4 Rotary Inter-digit Pause for Central Office (outgoing dialing), where 
t equals: 
0 = 400 ms 5 = 900 ms 
1 = 500 ms 6 = 1 second 
2 = 600 ms 7 = 1.1 seconds 
3 = 700 ms 8 = 1.2 seconds 
4 = 800 ms 
xzot 2 Incoming Ringing Sensitivity, where t...